Automation Controls Catalog
VDE
Ideal for solar inverter
compact size,
1a 35A/48A power relays
HE RELAYS
PV Type
• High insulation and 10,000 V surge
breakdown voltage (between contacts
and coil) achieved.
• Conforms to various safety
standards
UL/C-UL and VDE
FEATURES
• 35A/48A current at 250 V AC
achieved in compact size (L: 33
×
W:
38
×
H: 36.3 mm
L: 1.299
×
W: 1.496
×
H: 1.429 inch)
Due to improved conduction efficiency,
wide terminal blades are used. (for high
capacity type)
TYPICAL APPLICATIONS
RoHS compliant
• Photovoltaic power generation
systems (Solar inverter)
• Contact gap: 2.5 mm (VDE0126
compliant)
Compliant with European photovoltaic
standard VDE0126
Compliant with EN61810-1 2.5 kV surge
breakdown voltage (between contacts)
• Contributes to energy saving in
devices thanks to reduced coil hold
voltage
Coil hold voltage can be reduced down to
40% of the nominal coil voltage (ambient
temperature 20°C
68°F).
This equals to
operating power of approximately 310
mW.
*Coil hold voltage is the coil voltage after
100 ms following application of the
nominal coil voltage.
ORDERING INFORMATION
HE 1a
Contact arrangement
1a: 1 Form A (Single side stable type)
Pick-up voltage
N: 70% of nominal voltage
Terminals
P: PC board terminal type
Coil voltage (DC)
6, 9, 12, 24V
Type, contact material and switching capacity
Y5: PV type, AgNi type (1 Form A 48A high capacity)
H18: PV type, AgSnO
2
type (1 Form A 35A standard)
N
P
DC
2013.07
industrial.panasonic.com/ac/e/
–1–
©
Panasonic Corporation 2013
ASCTB101E 201307-T
HE PV Type
TYPES
Nominal coil
voltage
6V DC
9V DC
12V DC
24V DC
Standard type*
Part No.
HE1aN-P-DC6V-H18
HE1aN-P-DC9V-H18
HE1aN-P-DC12V-H18
HE1aN-P-DC24V-H18
High capacity type
Part No.
HE1aN-P-DC6V-Y5
HE1aN-P-DC9V-Y5
HE1aN-P-DC12V-Y5
HE1aN-P-DC24V-Y5
Standard packing: Carton: 20 pcs.; Case: 100 pcs.
*Standard 6V, 12V and 24V DC type: Certified by UL/C-UL (Standard 9V type: Certified by UL/C-UL and VDE)
RATING
1. Coil data
Nominal coil
voltage
6V DC
9V DC
12V DC
24V DC
70%V or less of
nominal voltage
10%V or more of
nominal voltage
Pick-up voltage
(at 20°C
68°F)
(Initial)
Drop-out voltage
(at 20°C
68°F)
(Initial)
Nominal operating
current
[±10%] (at 20°C
68°F)
320mA
213mA
160mA
80mA
Coil resistance
[±10%] (at 20°C
68°F)
18.8Ω
42.2Ω
75.0Ω
300.0Ω
1,920mW
110%V of
nominal voltage
Nominal operating
power
Max. applied voltage
(at 20°C
68°F)
2. Specifications
Characteristics
Arrangement
Contact
Contact resistance (Initial)
Contact material
Nominal switching capacity
Contact carring power
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (Reference value)*
1
Insulation resistance (Initial)
Between open contacts
Between contact and coil
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
Breakdown
voltage (Initial)
Item
Specifications
Standard type
1 Form A
Max. 100 mΩ (By voltage drop 6 V DC 1A)
AgNi type
AgSnO
2
type
35 A 250 V AC (Resistive load)
48 A 250 V AC (Resistive load)
8,750 VA (Resistive load)
250 V AC
35 A (AC)
1,920 mW
100 mA 5 V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
2,000 Vrms for 1 min. (Detection current: 10 mA)
5,000 Vrms for 1 min. (Detection current: 10 mA)
10,000 V
Max. 60°C
140°F
(By resistive method,
contact carrying current: 35A, 100%V of nominal
coil voltage at 55°C
131°F.)
Max. 30°C
86°F
(By resistive method, contact
carrying current: 35A, 60%V of nominal coil
voltage at 85°C
185°F.)
40 to 100%V (Contact carrying current:
35A, at 20°C
68°F),
50 to 100%V (Contact carrying current:
35A, at 55°C
131°F),
50 to 60%V (Contact carrying current:
35A, at 85°C
185°F)
Max. 60°C
140°F
(By resistive method,
contact carrying current: 48A, 100%V of nominal
coil voltage at 55°C
131°F.)
48 A (AC)
12,000 VA (Resistive load)
High capacity type
Rating
Temperature rise
Electrical
characteristics
Coil hold voltage*
3
Mechanical
characteristics
Operate time (at 20°C
68°F)
Release time (at 20°C
68°F)*
5
Functional
Shock
resistance
Destructive
Vibration
resistance
Mechanical
Resistive load
Functional
Destructive
Max. 30°C
86°F
(By resistive method, contact
carrying current: 48A, 60%V of nominal coil
voltage at 85°C
185°F.)
40 to 100%V (Contact carrying current:
48A, at 20°C
68°F),
50 to 100%V (Contact carrying current:
48A, at 55°C
131°F),
50 to 60%V (Contact carrying current:
48A, at 85°C
185°F)
Max. 30 ms (nominal coil voltage, excluding contact bounce time)
Max. 10 ms (nominal coil voltage, excluding contact bounce time) (without diode)
Min. 98 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10
µs.)
Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Expected life
Electrical
Inductive load
10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10
µs.)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 10
6
(at 180 times/min.)
Min. 3×10
4
(35 A 250 V AC) (ON : OFF = 1s : 9s) Min. 3×10
4
(48 A 250 V AC) (ON : OFF = 1s : 9s)
Endurance: 48 A 250 V AC (cos
φ
= 0.8),
Min. 3×10
4
(ON : OFF = 0.1s : 10s)
—
Overload: 72 A 250 V AC (cos
φ
= 0.8),
Min. 50 (ON : OFF = 0.1s : 10s)
Ambient temperature:
–50 to +55°C
–58 to +131°F
(When nominal coil voltage applied)
–50 to +85°C
–58 to +185°F
(When applied coil hold voltage is 50% to 60% of nominal coil voltage)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature);
Atmospheric pressure: 86 to 106 kPa
6 times/min. (at nominal switching capacity ON : OFF = 1s : 9s)
Approx. 80 g
2.82 oz
Conditions
Conditions for operation, transport and
storage*
4
Max. operating speed
Unit weight
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of
±1.2×50µs
according to JEC-212-1981
*3. Coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage.
*4. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*5. Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions.
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/
–2–
©
Panasonic Corporation 2013
ASCTB101E 201307-T
HE PV Type
REFERENCE DATA
1.-(1) Coil temperature rise
(Standard type)
Sample: HE1aN-P-DC9V-H18, 6 pcs.
Point measured: coil inside
Ambient temperature: 25°C
77°F,
60°C
140°F,
85°C
185°F
Contact carrying current: 35A
70
Temperature rise,
°C
Temperature rise,
°C
60
25°C
50
40
30
20
10
0
50
60
70
80
90
100
60°C
85°C
1.-(2) Coil temperature rise
(High capacity type)
Sample: HE1aN-P-DC9V-Y5, 6 pcs.
Point measured: coil inside
Ambient temperature: 25°C
77°F,
60°C
140°F,
85°C
185°F
Contact carrying current: 48A
70
60
50
40
30
20
10
0
50
60
70
80
90
100
25°C
60°C
85°C
Coil applied voltage, %V
Coil applied voltage, %V
2.-(1) Electrical life test (Standard type, Resistive load 250V AC, 35A at 85°C
185°F)
Sample: HE1aN-P-DC9V-H18, 6 pcs.
Change of pick-up and drop-out voltage
Operation frequency: 6 times/min.
(ON/OFF = 1.0s : 9.0s)
Pick-up and drop-out voltage, V
9
8
Change of contact resistance
100
90
Contact resistance, mΩ
80
70
60
50
40
30
20
10
Max.
x
Min.
3
No. of operations,
×10
4
Circuit:
7
6
5
4
3
2
1
0
0
No. of operations,
×10
4
250V AC
9V DC
Contact
welding
detection
and Mis-
contacting
detection
circuit
Pick-up voltage
Max.
x
Min.
Drop-out voltage
Max.
x
Min.
3
0
0
2.-(2) Electrical life test (High capacity type, Resistive load 250V AC, 48A at 85°C
185°F)
Sample: HE1aN-P-DC9V-Y5, 6 pcs.
Change of pick-up and drop-out voltage
Operation frequency: 6 times/min.
(ON/OFF = 1.0s : 9.0s)
Pick-up and drop-out voltage, V
9
8
Change of contact resistance
100
90
Contact resistance, mΩ
80
70
60
50
40
30
20
10
Max.
x
Min.
3
No. of operations,
×10
4
Circuit:
7
6
5
4
3
2
1
0
0
No. of operations,
×10
4
3
Drop-out voltage
Max.
x
Min.
Pick-up voltage
Max.
x
Min.
250V AC
9V DC
Contact
welding
detection
and Mis-
contacting
detection
circuit
0
0
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/
–3–
©
Panasonic Corporation 2013
ASCTB101E 201307-T
HE PV Type
DIMENSIONS
(mm
inch)
CAD Data
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
Standard type
External dimensions
38.0
1.496
33
1.299
Schematic (Bottom view)
Single side stable type
1
4
PC board pattern (Bottom view)
4.7
.185
24
.945
8.4
.331
0.5
.020
1.6
.063
4.7
.185
36.3
1.429
6
5
6-2 dia. hole
6-.079 dia. hole
18.6
.732
4
.157
0.8
.031
1.6
.063
0.8
.031
32
1.260
General tolerance:
±0.3
±.012
Tolerance:
±0.1
±.004
High capacity type
External dimensions
38.0
1.496
33
1.299
Schematic (Bottom view)
Single side stable type
1
4
PC board pattern (Bottom view)
6.5
.256
24
.945
8.4
.331
0.5
.020
36.3
1.429
6
5
1.3
.051
18.6
.732
2-2 dia. hole
2-.079 dia. hole
0.8
.031
6.3
.248
4
.157
1.6
.063
0.8
.031
32
1.260
General tolerance:
±0.3
±.012
Tolerance:
±0.1
±.004
SAFETY STANDARDS
Certification body
C-UL
High capacity type
VDE (VDE0435)
UL/CSA
VDE (VDE0435)**
Contact rating
48A 277V AC (at 85°C
185°F)
*60A 277V AC (general use, at 60°C
140°F,
10k cycle), in use at 60% of rated coil voltage
48A 250V AC cos
φ
= 0.8 (at 85°C
185°F)
*72A 250V AC (cos
φ
= 0.8 at 85°C
185°F,
50 cycle)
*60A 250V AC (cos
φ
= 0.8 at 85°C
185°F,
10k cycle)
*50A 20V DC (0ms, at 85°C
185°F,
30k cycle)
35A 277V AC (at 25°C
77°F)
35A 250V AC cos
φ
= 1 (at 80°C
176°F)
Standard type
* Under development. Please contact us.
** Only 9V DC type is Certified by VDE
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/
–4–
©
Panasonic Corporation 2013
ASCTB101E 201307-T
HE PV Type
NOTES
Usage, transport and storage
conditions
1) Temperature:
–50 to +55°C
–58 to +131°F
–50 to +85°C
–58 to +185°F
(When
applied coil hold voltage is 50% to 60% of
nominal coil voltage)
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage
Humidity, %RH
85
Tolerance range
(Avoid freezing
when used at
temperatures
lower than
0°C
32°F)
5
–50
–58
(Avoid
condensation
when used at
temperatures
higher than
0°C
32°F)
55
+131
Temperature,
°C
°F
Certification
This relay is UL/C-UL certified.
48 A 277 V AC (High capacity type)
35 A 277 V AC (Standard type)
This relay is certified by VDE
48 A 250 V AC cos
φ
= 0.8
(High capacity type)
35 A 250 V AC cos
φ
= 1
(Standard type)
0
+32
Humidity, %RH
85
Tolerance range
(Avoid freezing
when used at
temperatures
lower than
0°C
32°F)
5
–50
–58
(Avoid
condensation
when used at
temperatures
higher than
0°C
32°F)
85
+185
0
+32
Temperature,
°C
°F
∗
–50 to +85°C
–58 to +185°F
(When applied
coil hold voltage is 50% to 60% of nominal
coil voltage)
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/
–5–
©
Panasonic Corporation 2013
ASCTB101E 201307-T