3.6KVWDLSJ100

Description
Electric Fuse, 100A, 3600VAC, 3600VDC, 50000A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size56KB,1 Pages
ManufacturerEaton
Download Datasheet Parametric View All

3.6KVWDLSJ100 Overview

Electric Fuse, 100A, 3600VAC, 3600VDC, 50000A (IR), Inline/holder,

3.6KVWDLSJ100 Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codecompliant
ECCN codeEAR99
body height50.8 mm
Body length or diameter292.1 mm
Circuit protection typeELECTRIC FUSE
Installation featuresINLINE/HOLDER
physical size292.1mm x 50.8mm
Rated breaking capacity50000 A
Rated current100 A
Rated voltage (AC)3600 V
Rated voltage (DC)3600 V
surface mountNO
Terminal shapeTAB/BLADE
Medium Voltage Fuses
British Standard dimensioned IEC fuses for
motor circuit protection
The Cooper Bussmann® range of motor fuses are designed
to meet the specific requirements necessary for motor
protection. During the starting cycle of direct on-line motors,
the fuse elements will reach a considerably higher
temperature than during normal operation; (this is due to the
high amount of current the motor will draw as it starts,
typically, 6 times its normal load current value). This results
in expansion and contraction of the fuse elements and could
cause premature operation of the fuse.
Cooper Bussmann
®
motor fuses encompass an advanced
design to minimize this effect. This therefore, negates the
need to over specify the fuse rating due to high values of
motor starting current.
Cooper Bussmann
®
motor fuses operate extremely quickly
under heavy fault currents, resulting from the time / current
characteristic. Low power dissipation ensures low
temperature rise, important in multi-tier starters for example.
Switching (Arc), voltages are lower than permitted values,
therefore, 5.5kV fuses are also suitable for 4.8kV and
2.4kV circuits.
Table of Ratings
Basic Cat.
Number
WJON6
WDOH6
WFOH6
WDLSJ
WFLSJ
WDFHO
WFFHO
WKFHO
VFNHA
VKNHA
WFNHO
WKNHO
WFMSJ
WKMSJ
Volts
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
5.5kV
5.5kV
7.2kV
7.2kV
7.2kV
7.2kV
Breaking
Capacity
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
60kA
60kA
40kA
40kA
40kA
40kA
Dimensions - in (mm)
Amp Ratings
Length
Diameter
5, 6.3, 10, 16, 20, 25, 31.5, 40, 50
7.56 (192)
1.4 (35.6)
50, 63, 80, 100, 125
7.56 (192)
2 (50.8)
160, 200
11.5 (292.1)
3 (76.2)
50, 63, 80, 100, 125
11.5 (292.1)
2 (50.8)
160, 200
11.5 (292.1)
3 (76.2)
50, 63, 80, 100, 125
10 (254)
2 (51mm)
160, 200
10 (254)
3 (76.2)
250, 315, 355, 400
10 (254)
3 (76.2)
2R-6R
15.86 (402.8)
3 (76.2)
9R-24R
15.86 (402.8)
3 (76.2)
25, 31.5, 40, 50, 63, 80, 100, 125, 160 15.86 (402.8)
3 (76.2)
200, 224, 250, 315
15.86 (402.8)
3 (76.2)
25, 31.5, 40, 50, 63, 80, 125, 160
17.40 (442)
3 (76.2)
200, 224, 250, 315, 355
17.40 (442)
3 (76.2)
Dimensional Standard
BS 2692 (TA1) Interchangeable with GEC type K2 PA
BS 2692 (TA1) or DIN 43625
BS 2692 (TA1) or DIN 43625
DIN 43625
DIN 43625
BS 2692 (TA2)
BS 2692 (TA2)
BS 2692 (TA2)
N. American Practice
N. American Practice
BS 2692 (TA4)
BS 2692 (TA4)
DIN 43625
DIN 43625
Catalog Number Build-A-Code
kV
Basic Catalog Number
___
_____
Amps
___
80
For product Data Sheets, visit www.cooperbussmann.com/products/datasheet.asp
How to Use an Operational Amplifier
I'm sharing this with you, I wonder if it can be helpful.[[i] This post was last edited by zzz-0909 on 2009-3-9 12:11[/i]]...
zzz-0909 Analog electronics
Timer
Can someone please help me see why the timer 1 interrupt cannot be entered and the Timer_Flag does not increase. Is the initialization written incorrectly?...
zhangxiaobudong 51mcu
[Problem Feedback] Anlu TangDynasty ChipWatcher network search problem
I think that similar to this, the logic of entering keywords in the text box after Name to search for the corresponding network should be changed to directly detecting text modification events. Becaus...
littleshrimp FPGA/CPLD
Bluetooth 5.1, NFC, Thread/ZigBee on one board, apply for ublox wireless development board EVK-NINA-B400 for free!
Event details: https://bbs.eeworld.com.cn/elecplay/content/168Application deadline: April 21 Development board model: EVK-NINA-B400Enter the event page, fill out the application form, and you can appl...
okhxyyo RF/Wirelessly
Welcome to Test/Measurement Moderator
Welcome to Test/Measurement Moderator...
yanmei Test/Measurement
Several points for attention in testing with four-probe resistivity tester
The characteristic of the four-probe resistivity tester is that the host is equipped with dual digital meters. While measuring the resistivity, another digital meter (with an accuracy of a few ten-tho...
qwqwqw2088 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2330  1371  980  758  306  47  28  20  16  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号