EEWORLDEEWORLDEEWORLD

Part Number

Search

805-004-07-M8-1SA

Description
Circular Connector, 1 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size485KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance  
Download Datasheet Parametric View All

805-004-07-M8-1SA Overview

Circular Connector, 1 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,

805-004-07-M8-1SA Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerGlenair
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationGOLD OVER NICKEL
Contact completed and terminatedGold (Au) - with Nickel (Ni) barrier
Contact point genderFEMALE
Contact materialBERYLLIUM COPPER
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceNO
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceNICKEL PLATED
Shell materialALUMINUM ALLOY
Housing size8
Termination typeCRIMP
Total number of contacts1
A
B
C
D
E
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
Series 805
Series 805 “Mighty Mouse”
Triple-Start
Series 805 Receptacles
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, square flange for front
or rear panel mounting, or in-line
receptacles for free-hanging cables.
Two Shell Styles:
Choose
integral
band platform
for direct attachment
of a cable shield. Install a boot,
or overmold a boot over the band
platform.
Gold-Plated Crimp Contacts
are held in place with beryllium
copper retention clips. Contacts are
removable.
Series 805 Triple-Start
Jam Nut Connector
An
accessory thread
is available
for attaching strain reliefs and
backshells.
HOW TO ORDER
Sample Part Number
80 5- 0 0 4
Series
-02
Shell Style
NF
Shell Material /
Finish
C
Aluminum / Black
Anodize
9-10
Shell Size- Insert
Arrangement
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
15-37
37 #23 Contacts
18-55
55 #23 Contacts
19-85
85 #23 Contacts
Size #23 contacts are
supplied with connectors.
Other contact sizes are
ordered separately.
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
A
Shell Key
Position
A
Position A
(Normal)
M
-01
805-003
Receptacle with
Banding Platform
In-Line
Aluminum / Electroless
Nickel
NF
Aluminum / Cadmium
with Olive Drab
Chromate
8-1
8-4
8-7
9-1
9-10
10-13
11-4
11-19
12-26
15-2
B
Position B
P
Pin
C
Position C
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
D
Position D
ZN
-02
Square Flange
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
805-004
Receptacle with
Accessory Thread
-07
Jam Nut for Rear
Panel Mounting
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
H-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
[TI Wireless Theme Collection] + CC2540 Bluetooth connects two computers
[i=s]This post was last edited by ddllxxrr on 2014-11-28 11:11[/i] Two modules, one as a server and one as a client. The client receives serial port data and writes it into a characteristic value. The...
ddllxxrr Wireless Connectivity
I have a question about CAN baud rate setting
I'm currently using the SJA1000 CAN communication IC. When testing the baud rate, I found that I was using two identical boards, both with SJA1000 chips and the same program initialization. Except for...
pcf2000 NXP MCU
Question + How do you use TI wireless watches?
How do you use TI wireless watches? Do you use them when you go out for exercise? And how do you set the time? There are more and more wireless smart watches now. Have you used TI's?...
fxw451 Microcontroller MCU
Why is the type of U0IIR in keil4 watch char type data?
Now I want to use the automatic baud rate function (interrupt mode) of the NXP1700 series. I need to monitor the 8th and 9th bits of U0IIR. However, when simulating, the type of U0IIR is char data. Th...
15033509935 Analog electronics
C64X DSP EDMA Summary and Example Detailed Explanation (ZZ)
C64X DSP EDMA Summary (1) EDMA Overview ① EDMA data transmission has two initiation methods:CPU-initiated EDMA data transmission (asynchronous mode): When transmission is required, the CPU sets the co...
DSP16 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1090  2172  379  1930  2691  22  44  8  39  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号