EEWORLDEEWORLDEEWORLD

Part Number

Search

IT-60

Description
60W Isolated Triple Output Switching Power Supply
File Size178KB,2 Pages
ManufacturerRSG Electronic Components GmbH
Websitehttp://www.rsg-electronic.de/de/
Download Datasheet Compare View All

IT-60 Online Shopping

Suppliers Part Number Price MOQ In stock  
IT-60 - - View Buy Now

IT-60 Overview

60W Isolated Triple Output Switching Power Supply

ELECTRONIC COMPONENTS
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de
www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
60W Isolated Triple Output Switching Power Supply
Features :
I T- 6 0
series
Isolated output & GND for CH1,CH2,CH3
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 67KHz
2 years warranty
SPECIFICATION
MODEL
OUTPUT
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
PEAK LOAD (3sec.)
VOLTAGE ADJ. RANGE
IT-60D
CH1
5V
3A
0.5 ~ 3A
58.2W
Note.4
70W
IT-60F
CH2
12V
0.8A
0.1 ~ 1A
CH3
24V
1.4A
0.2 ~ 2A
CH1
5V
3A
0.5 ~ 3A
58.2W
120mVp-p
8.0%
2.0%
5.0%
240mVp-p
8.0%
2.0%
5.0%
80mVp-p
CH1 : 4.75 ~ 5.5V
3.0%
1.0%
2.0%
150mVp-p
8.0%
2.0%
5.0%
240mVp-p
8.0%
2.0%
5.0%
CH2
15V
0.8A
0.1 ~ 1A
CH3
24V
1.3A
0.2 ~ 2A
RIPPLE & NOISE (max.)
Note.2
80mVp-p
CH1 : 4.75 ~ 5.5V
VOLTAGE TOLERANCE
Note.3
3.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
1.0%
2.0%
300ms, 20ms/230VAC
80ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
76%
800ms, 20ms/115VAC at full load
18ms/115VAC at full load
127 ~ 370VDC
INPUT
1.8A/115VAC
0.9A/230VAC
COLD START 20A/115VAC
40A/230VAC
<1mA / 240VAC
72 ~ 90W rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
ENVIRONMENT
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
EMC
(Note 5)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, Light industry level, criteria A
314.3K hrs min. MIL-HDBK-217F (25 )
159*97*38mm (L*W*H)
0.51Kg; 24pcs/13.2Kg/0.75CUFT
OTHERS
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 5% Duty cycle maximum within every 1min. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:IT-60-SPEC 2006-08-01

IT-60 Related Products

IT-60 IT-60D IT-60F
Description 60W Isolated Triple Output Switching Power Supply 60W Isolated Triple Output Switching Power Supply 60W Isolated Triple Output Switching Power Supply
How to set the serial port baud rate of MSP430
Given a BRCLK clock source, the baud rate is used to determine the factor N that needs to be divided: N = fBRCLK/Baudrate The division factor N is usually a non-integer value, so at least one divider ...
fish001 Microcontroller MCU
Urgent solution?
Can ADS1115 be accurate to UV level? Mine is only accurate to milliseconds, and the error is in millivolt level. How can I solve this problem?...
单片机初学者AAA Microcontroller MCU
Two LPC800 miniKITs for wangfuchong's LanchPad plus touchpad
As mentioned in a previous post, I was planning to replace the MSP430 stuff. Wangfuchong happened to have extra MSP430 boards. Yesterday, we negotiated to exchange them so as not to waste board resour...
wgsxsm Buy&Sell
Tips for getting STM32 code running time
Preface There are two ways to test the runtime of your code: 1. Use the internal timer of the microcontroller to start the timer at the beginning of the program segment to be tested and turn it off at...
可乐zzZ stm32/stm8
Solution to the warning when calling IP core synthesis
Today I suddenly saw a tutorial with an example of calling an IP core to do addition operations. After reading it, I wanted to implement it on ISE. I generated two adder cores, adder16 and adder17. Du...
lvfanzai FPGA/CPLD
VxWorks network is prone to crash when receiving and sending large amounts of data
The network is prone to crash when the amount of network transmission and reception is large. There are 3 network chips RTL8139, system vxWorks5.5, multi-process applications, both udp and tcp. One ne...
wto4tnt Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1060  54  1230  2023  2791  22  2  25  41  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号