Unregulated DC/DC Converter; In-V: 15; Out-V: 05; In V MIN: 13.5; In V MAX: 16.5; Out V MIN: 5; Out V MAX: 5; Out-mA: 200; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 15; MC OUTPUT-V: 5; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
Unregulated DC/DC Converter; In-V: 15; Out-V: 05; In V MIN: 13.5; In V MAX: 16.5; Out V MIN: 5; Out V MAX: 5; Out-mA: 200; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 15; MC OUTPUT-V: 5; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
The REM1 complements the existing board-mount REM3, REM6 and REM10 series by offering
a 1W medical grade unregulated DC/DC converter in a more compact SIP7 package. The REM1
features reinforced 5.2kVDC/1 minute isolation and 2MOPP/250VAC working voltage. The REM1 is
available with 3.3, 5, 12, 15 or 24V inputs and offers 3.3, 5 or 12V outputs with up to 85%
efficiency. The operating temperature range is -40°C up to +90°C. The converter is Class B EMC and
60601-1-2 (4th Ed.) medical EMC certified using a simple external LC filter. The converters are
fully certified to CB, IEC/EN and ANSI/AAMI 60601 third edition safety standards, RoHS2+ (10/10)
and REACH and come with a 5 year warranty.
rranty
Selection Guide
Part
Number
REM1-3.33.3S
REM1-3.305S
REM1-3.312S
REM1-053.3S
REM1-0505S
REM1-0512S
REM1-123.3S
REM1-1205S
REM1-153.3S
REM1-1505S
REM1-243.3S
REM1-2405S
nom. Input
Voltage
[VDC]
3.3
3.3
3.3
5
5
5
12
12
15
15
24
24
Output
Voltage
[VDC]
3.3
5
12
3.3
5
12
3.3
5
3.3
5
3.3
5
Output
Current
[mA]
303
200
84
303
200
84
303
200
303
200
303
200
Efficiency
typ.
(1)
[%]
78
81
85
79
80
84
78
81
77
81
76
80
Max. Capacitive
Load
(2)
[µF]
2200
2200
470
2200
2200
470
2200
2200
2200
2200
2200
2200
E314885
2MOPP
250VAC
IEC/EN60601-1 certified
ANSI/AAMI ES60601-1 certified
EN62368-1 certified
IEC/EN60601-1-2
EN55011
CB Report
Notes:
Note1: Efficiency tested by nominal input and full load at +25°C ambient.
Note2: Max Cap Load tested by nominal input and full resisitive load.
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
BASIC CHARACTERISTICS
Parameter
Internal Input Filter
3.3VDC
5VDC
nom. Vin= 12VDC
15VDC
24VDC
3.3VDC
5VDC
nom. Vin= 12VDC
15VDc
24VDC
continued on next page
www.recom-power.com
REV.: 2/2017
MED-1
Condition
Min.
2.97VDC
4.5VDC
10.8VDC
13.5VDC
21.6VDC
Typ.
Max.
Capacitor
3.63VDC
5.5VDC
13.2VDC
16.5VDC
26.4VDC
0VDC
40mA
25mA
12mA
10mA
7mA
Input Voltage Range
Maximum Reverse Voltage
Quiescent Current
REM1
DC/DC Converter
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
Parameter
Internal Operating Frequency
Minimum Load
Output Ripple and Noise
(3)
20MHz BW
Notes:
Note3: Measurements are made with a 0.1µF MLCC across output. (low ESR).
Series
Condition
Min.
Typ.
40kHz
0%
75mVp-p
Max.
Efficiency vs. Load
100
90
80
REM1-xx3.3S
100
90
80
70
REM1-xx05S
Efficiency [%]
Efficiency [%]
70
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
3.33.3
053.3
123.3
153.3
243.3
90
100
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
3.305
0505
1205
1505
2405
90
100
Load Current [A]
Load Current [A]
100
90
80
70
REM1-xx12S
Efficiency [%]
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
3.312
0512
90
100
Load Current [A]
Tolerance Envelope
REM1-3.33.3S
+12
Output Voltage [%]
REM1-2405S
Output Voltage [%]
+8
+3
V Nom.
+6
V Nom.
Typica
l
Load L
ine
+5
-0.5
-5
Typica
l
Load L
ine
+5
-0.5
-5
10
50
100
+Vout and -Vout Load Current [%]
MED-2
REV.: 2/2017
10
50
100
+Vout and -Vout Load Current [%]
www.recom-power.com
REM1
DC/DC Converter
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Load Regulation
low line to high line, full load
10% to 100% load
3.3Vout and 5Vout
12Vout
Series
Condition
Value
±5% max.
±1.2% typ. @ 1% of Vin
±8% typ. / ±12% max.
±5% typ. / ±8% max.
Accuracy vs. Load
30
25
20
REM1-xx3.3S
3.33.3
053.3
123.3
153.3
243.3
30
25
20
REM1-xx05S
3.305
0505
1205
1505
2405
Deviation [%]
15
10
5
0
-5
-10
0
10
20
30
40
50
60
70
80
90
100
Deviation [%]
15
10
5
0
-5
-10
0
10
20
30
40
50
60
70
80
90
100
Load Current [A]
Load Current [A]
REM1-xx12S
30
25
20
3.312
0512
Deviation [%]
15
10
5
0
-5
-10
0
10
20
30
40
50
60
70
80
90
100
Load Current [A]
PROTECTIONS
Parameter
Isolation Voltage
(4)
Isolation Resistance
Isolation Capacitance
Insulation Grade
Means of Protection
Creepage and Clearance
Notes:
Note4: For repeat Hi-Pot testing, reduce the time and/or the test voltage.
Note5: An input fuse is required if the mains supply is not over-current protected. Recommended fuse: T1A slow blow type
www.recom-power.com
REV.: 2/2017
MED-3
Type
I/P to O/P
tested for 1 minute
Value
5.2kVDC
4kVAC
10GΩ min.
25pF typ.
reinforced
250VAC working voltage
2MOPP
≥8mm
REM1
DC/DC Converter
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
ENVIRONMENTAL
Parameter
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
Operating Altitude
Operating Humidity
Pollution Degree
MTBF
Vibration
according to MIL-HDBK-217F, G.B.
+25°C
+85°C
according to IEC/EN60601-1
accroding to IEC/EN62368-1
non-condensing
Series
Condition
without derating (see graph)
Value
-40°C °C to +85°C
105°C
0.02%/°C typ.
3000m
5000m
5% - 95% RH max.
PD2
18200 x 10
3
hours
7500 x 10
3
hours
according to MIL-STD-202G standard
Derating Graph
(@ chamber and natural convection 0.1m/s)
100
80
60
40
30
20
0
-40
Output Power [%]
-20
0
20
40
60
Ambient Temperature [°C]
80 100
85 90
120
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Audio/video, information and communication technology equipment. Safety
requirements (CB Scheme)
Medical Electric Equipment, General Requirements for Saftey and Essential
Performance
Medical Electric Equipment, General Requirements for Safety and Essential
Performance
RoHs2+
Report / File Number
L0339m31-A-L
E314885-D1000-1/A0/C0-UL
E314885-D1000-1/A0/C0-CB
Standard
EN62368-1:2014
ANSI/AAMI ES60601-1:2012 + A2 2010/2012
CSA C22.2 No. 60601-1:14, 3rd Edition, 2014
IEC60601-1:2005 +AM1:2012
EN60601-1:2006 + A12:2014
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Medical electrical equipment - Part 1-2: General requirements for basic safety
and essential performance - Collateral standard: Electromagnetic compatibility
Industrial, scientific and medical equipment - Radio frequency disturbance
characteristics - Limits and methods of measurement
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Condition
Standard / Criterion
IEC60601-1-2:2014
EN60601-1-2:2015
with external filter
air: ±15kV; contact: ±8kV
3V/m
DC port: ±2kV
DC port: ±1kV
DC port: 6V
50Hz, 30A/m
EN55011, 2009+A1:2010, Class B
IEC61000-4-2:2008 , Criteria A
IEC61000-4-3:2006+A2:2010, Criteria A
IEC61000-4-4:2012, Criteria A
IEC61000-4-5:2014, Criteria B
IEC61000-4-6:2013, Criteria A
IEC61000-4-8:2009, Criteria A
continued on next page
MED-4
REV.: 2/2017
www.recom-power.com
REM1
DC/DC Converter
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
EMC Filtering Suggestions according to EN55011
Series
C2
Component list Class B
Input Voltage
3.3VDC
5VDC
LOAD
L1
C1
4.7µF
C2
L1
22µH Choke
+Vin
C1
-Vin
12VDC
15VDC
24VDC
470pF/6kVDC
2.2µF
47µH Choke
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Material
Package Dimension (LxWxH)
Package Weight
Type
Case
Potting
PCB
Value
black plastic, (UL94 V-0)
silicone (UL94 V-0)
FR4 (UL94 V-0)
19.6 x 6.0 x 10.2mm
2.6g typ.
Dimension Drawing (mm)
embossed logo
19.6
6.0
0.50
4.1
1 2
6 7
Marking
Pin Connections
Pin #
Single
1
+Vin
2
-Vin
6
-Vout
7
+Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
Pin dimension:
±0.1mm
0.51
recommended footprint detail
10.2
1.00 Ø +0.15/-0
2.54
1.27
0.25
Bottom View
Top View
2.54
2.0
6x2.54= 15.24
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Storage Temperature Range
Storage Humidtiy
non-condensing
Type
tube
Value
520.0 x 16.0 x 9.3mm
25pcs
-55°C to +125°C
TBD
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
Unregulated DC/DC Converter; In-V: 15; Out-V: 05; In V MIN: 13.5; In V MAX: 16.5; Out V MIN: 5; Out V MAX: 5; Out-mA: 200; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 15; MC OUTPUT-V: 5; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
DC-DC Unregulated Power Supply Module, 1 Output, 1W, Hybrid, SIP-7/4
DC-DC Unregulated Power Supply Module, 1 Output, 1W, Hybrid, SIP-7/4
Unregulated DC/DC Converter; In-V: 05; Out-V: 12; In V MIN: 4.5; In V MAX: 5.5; Out V MIN: 12; Out V MAX: 12; Out-mA: 84; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 5; MC OUTPUT-V: 12; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
Unregulated DC/DC Converter; In-V: 15; Out-V: 3.3; In V MIN: 13.5; In V MAX: 16.5; Out V MIN: 3.29999999999999; Out V MAX: 3.29999999999999; Out-mA: 303; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 15; MC OUTPUT-V: 3.3; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
Unregulated DC/DC Converter; In-V: 24; Out-V: 3.3; In V MIN: 21.6; In V MAX: 26.3999999999999; Out V MIN: 3.29999999999999; Out V MAX: 3.29999999999999; Out-mA: 303; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 24; MC OUTPUT-V: 3.3; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
DC-DC Unregulated Power Supply Module, 1 Output, 1W, Hybrid, SIP-7/4
When I was working on the HPI interface, a problem occurred: after enabling the arm's nwait, the dsp's /hrdy was connected to the nwait after conversion through the NOT gate. Then, the arm would freez...
The Adafruit Funhouse development board is based on the new ESP32-S2 Wi-Fi microcontroller and integrates temperature, air pressure, humidity, and light sensors, giving you the basic information for a...
I need to use the three ADCs of STM32L4 to collect three data at the same time, and use a timer to trigger sampling. However, STM32L4 only has dual ADC mode, not triple ADC mode. Now if I use one chan...
At present, the development of wireless power supply technology for electric vehicles (EVs) is becoming more and more active. In 2012, Volvo of Sweden established Volvo Technology Japan in Tokyo as...[Details]
A single-chip microcomputer is also called a single-chip microcontroller. It is not a chip that completes a certain logical function, but a computer system integrated into one chip. In general, a c...[Details]
1. Overview
Will passive devices
produce nonlinear intermodulation distortion? The answer is yes! Although there is no systematic theoretical analysis, it has been found in engineerin...[Details]
1. Introduction
Since the 1980s, with the continuous development of automotive electronic technology, there are more and more electronic control units in automobiles, such as electronic fuel i...[Details]
Automotive applications are particularly sensitive to EMI events, which are unavoidable in a noisy electrical environment consisting of a central battery, bundled wiring harnesses, various inductiv...[Details]
In order to highlight the concept of "energy saving and environmental protection" of intelligent buildings, solar street lights are designed for intelligent communities. The inclination and capacit...[Details]
Although it is relatively easy to check the stability of a simple amplifier at lower frequencies, it may be much more difficult to evaluate the stability of a more complex circuit. This artic...[Details]
A multi-point temperature control heating control system was designed using the SST89E564RC single-chip microcomputer and a new temperature measuring device. The heating system can be controlled in...[Details]
1. System Structure
This system is a simulation system of indoor air-conditioning temperature/humidity control system. The data acquisition and control center collects temperature/humidity...[Details]
my country is a big country in agriculture, grain production and consumption. Grains are a necessary condition for our nation to survive and develop. The flour processing industry will exist forever w...[Details]
This paper designs a 16x16LED Chinese character display bar based on single-chip dynamic scanning control, briefly analyzes the principle of Chinese character display, and studies how the LED displ...[Details]
The serial interface real-time clock chip DS1302 launched by Dallas Company in the United States can trickle charge the backup battery of the clock chip. Due to the main features of the chip such a...[Details]
0 Introduction
There are many types of sensors, and the working principles, measurement targets and measurement environments of different types of sensors vary greatly. The corresponding detection s...[Details]
Fruit planting is an important part of China's agricultural development, and fruit tree pest control operations are becoming more and more important. At present, the overall level of pesticide applica...[Details]