The REM1 complements the existing board-mount REM3, REM6 and REM10 series by offering
a 1W medical grade unregulated DC/DC converter in a more compact SIP7 package. The REM1
features reinforced 5.2kVDC/1 minute isolation and 2MOPP/250VAC working voltage. The REM1 is
available with 3.3, 5, 12, 15 or 24V inputs and offers 3.3, 5 or 12V outputs with up to 85%
efficiency. The operating temperature range is -40°C up to +90°C. The converter is Class B EMC and
60601-1-2 (4th Ed.) medical EMC certified using a simple external LC filter. The converters are
fully certified to CB, IEC/EN and ANSI/AAMI 60601 third edition safety standards, RoHS2+ (10/10)
and REACH and come with a 5 year warranty.
rranty
Selection Guide
Part
Number
REM1-3.33.3S
REM1-3.305S
REM1-3.312S
REM1-053.3S
REM1-0505S
REM1-0512S
REM1-123.3S
REM1-1205S
REM1-153.3S
REM1-1505S
REM1-243.3S
REM1-2405S
nom. Input
Voltage
[VDC]
3.3
3.3
3.3
5
5
5
12
12
15
15
24
24
Output
Voltage
[VDC]
3.3
5
12
3.3
5
12
3.3
5
3.3
5
3.3
5
Output
Current
[mA]
303
200
84
303
200
84
303
200
303
200
303
200
Efficiency
typ.
(1)
[%]
78
81
85
79
80
84
78
81
77
81
76
80
Max. Capacitive
Load
(2)
[µF]
2200
2200
470
2200
2200
470
2200
2200
2200
2200
2200
2200
E314885
2MOPP
250VAC
IEC/EN60601-1 certified
ANSI/AAMI ES60601-1 certified
EN62368-1 certified
IEC/EN60601-1-2
EN55011
CB Report
Notes:
Note1: Efficiency tested by nominal input and full load at +25°C ambient.
Note2: Max Cap Load tested by nominal input and full resisitive load.
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
BASIC CHARACTERISTICS
Parameter
Internal Input Filter
3.3VDC
5VDC
nom. Vin= 12VDC
15VDC
24VDC
3.3VDC
5VDC
nom. Vin= 12VDC
15VDc
24VDC
continued on next page
www.recom-power.com
REV.: 2/2017
MED-1
Condition
Min.
2.97VDC
4.5VDC
10.8VDC
13.5VDC
21.6VDC
Typ.
Max.
Capacitor
3.63VDC
5.5VDC
13.2VDC
16.5VDC
26.4VDC
0VDC
40mA
25mA
12mA
10mA
7mA
Input Voltage Range
Maximum Reverse Voltage
Quiescent Current
REM1
DC/DC Converter
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
Parameter
Internal Operating Frequency
Minimum Load
Output Ripple and Noise
(3)
20MHz BW
Notes:
Note3: Measurements are made with a 0.1µF MLCC across output. (low ESR).
Series
Condition
Min.
Typ.
40kHz
0%
75mVp-p
Max.
Efficiency vs. Load
100
90
80
REM1-xx3.3S
100
90
80
70
REM1-xx05S
Efficiency [%]
Efficiency [%]
70
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
3.33.3
053.3
123.3
153.3
243.3
90
100
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
3.305
0505
1205
1505
2405
90
100
Load Current [A]
Load Current [A]
100
90
80
70
REM1-xx12S
Efficiency [%]
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
3.312
0512
90
100
Load Current [A]
Tolerance Envelope
REM1-3.33.3S
+12
Output Voltage [%]
REM1-2405S
Output Voltage [%]
+8
+3
V Nom.
+6
V Nom.
Typica
l
Load L
ine
+5
-0.5
-5
Typica
l
Load L
ine
+5
-0.5
-5
10
50
100
+Vout and -Vout Load Current [%]
MED-2
REV.: 2/2017
10
50
100
+Vout and -Vout Load Current [%]
www.recom-power.com
REM1
DC/DC Converter
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Load Regulation
low line to high line, full load
10% to 100% load
3.3Vout and 5Vout
12Vout
Series
Condition
Value
±5% max.
±1.2% typ. @ 1% of Vin
±8% typ. / ±12% max.
±5% typ. / ±8% max.
Accuracy vs. Load
30
25
20
REM1-xx3.3S
3.33.3
053.3
123.3
153.3
243.3
30
25
20
REM1-xx05S
3.305
0505
1205
1505
2405
Deviation [%]
15
10
5
0
-5
-10
0
10
20
30
40
50
60
70
80
90
100
Deviation [%]
15
10
5
0
-5
-10
0
10
20
30
40
50
60
70
80
90
100
Load Current [A]
Load Current [A]
REM1-xx12S
30
25
20
3.312
0512
Deviation [%]
15
10
5
0
-5
-10
0
10
20
30
40
50
60
70
80
90
100
Load Current [A]
PROTECTIONS
Parameter
Isolation Voltage
(4)
Isolation Resistance
Isolation Capacitance
Insulation Grade
Means of Protection
Creepage and Clearance
Notes:
Note4: For repeat Hi-Pot testing, reduce the time and/or the test voltage.
Note5: An input fuse is required if the mains supply is not over-current protected. Recommended fuse: T1A slow blow type
www.recom-power.com
REV.: 2/2017
MED-3
Type
I/P to O/P
tested for 1 minute
Value
5.2kVDC
4kVAC
10GΩ min.
25pF typ.
reinforced
250VAC working voltage
2MOPP
≥8mm
REM1
DC/DC Converter
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
ENVIRONMENTAL
Parameter
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
Operating Altitude
Operating Humidity
Pollution Degree
MTBF
Vibration
according to MIL-HDBK-217F, G.B.
+25°C
+85°C
according to IEC/EN60601-1
accroding to IEC/EN62368-1
non-condensing
Series
Condition
without derating (see graph)
Value
-40°C °C to +85°C
105°C
0.02%/°C typ.
3000m
5000m
5% - 95% RH max.
PD2
18200 x 10
3
hours
7500 x 10
3
hours
according to MIL-STD-202G standard
Derating Graph
(@ chamber and natural convection 0.1m/s)
100
80
60
40
30
20
0
-40
Output Power [%]
-20
0
20
40
60
Ambient Temperature [°C]
80 100
85 90
120
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Audio/video, information and communication technology equipment. Safety
requirements (CB Scheme)
Medical Electric Equipment, General Requirements for Saftey and Essential
Performance
Medical Electric Equipment, General Requirements for Safety and Essential
Performance
RoHs2+
Report / File Number
L0339m31-A-L
E314885-D1000-1/A0/C0-UL
E314885-D1000-1/A0/C0-CB
Standard
EN62368-1:2014
ANSI/AAMI ES60601-1:2012 + A2 2010/2012
CSA C22.2 No. 60601-1:14, 3rd Edition, 2014
IEC60601-1:2005 +AM1:2012
EN60601-1:2006 + A12:2014
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Medical electrical equipment - Part 1-2: General requirements for basic safety
and essential performance - Collateral standard: Electromagnetic compatibility
Industrial, scientific and medical equipment - Radio frequency disturbance
characteristics - Limits and methods of measurement
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Condition
Standard / Criterion
IEC60601-1-2:2014
EN60601-1-2:2015
with external filter
air: ±15kV; contact: ±8kV
3V/m
DC port: ±2kV
DC port: ±1kV
DC port: 6V
50Hz, 30A/m
EN55011, 2009+A1:2010, Class B
IEC61000-4-2:2008 , Criteria A
IEC61000-4-3:2006+A2:2010, Criteria A
IEC61000-4-4:2012, Criteria A
IEC61000-4-5:2014, Criteria B
IEC61000-4-6:2013, Criteria A
IEC61000-4-8:2009, Criteria A
continued on next page
MED-4
REV.: 2/2017
www.recom-power.com
REM1
DC/DC Converter
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
EMC Filtering Suggestions according to EN55011
Series
C2
Component list Class B
Input Voltage
3.3VDC
5VDC
LOAD
L1
C1
4.7µF
C2
L1
22µH Choke
+Vin
C1
-Vin
12VDC
15VDC
24VDC
470pF/6kVDC
2.2µF
47µH Choke
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Material
Package Dimension (LxWxH)
Package Weight
Type
Case
Potting
PCB
Value
black plastic, (UL94 V-0)
silicone (UL94 V-0)
FR4 (UL94 V-0)
19.6 x 6.0 x 10.2mm
2.6g typ.
Dimension Drawing (mm)
embossed logo
19.6
6.0
0.50
4.1
1 2
6 7
Marking
Pin Connections
Pin #
Single
1
+Vin
2
-Vin
6
-Vout
7
+Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
Pin dimension:
±0.1mm
0.51
recommended footprint detail
10.2
1.00 Ø +0.15/-0
2.54
1.27
0.25
Bottom View
Top View
2.54
2.0
6x2.54= 15.24
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Storage Temperature Range
Storage Humidtiy
non-condensing
Type
tube
Value
520.0 x 16.0 x 9.3mm
25pcs
-55°C to +125°C
TBD
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
DC-DC Unregulated Power Supply Module, 1 Output, 1W, Hybrid, SIP-7/4
DC-DC Unregulated Power Supply Module, 1 Output, 1W, Hybrid, SIP-7/4
DC-DC Unregulated Power Supply Module, 1 Output, 1W, Hybrid, SIP-7/4
Unregulated DC/DC Converter; In-V: 05; Out-V: 12; In V MIN: 4.5; In V MAX: 5.5; Out V MIN: 12; Out V MAX: 12; Out-mA: 84; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 5; MC OUTPUT-V: 12; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
Unregulated DC/DC Converter; In-V: 15; Out-V: 05; In V MIN: 13.5; In V MAX: 16.5; Out V MIN: 5; Out V MAX: 5; Out-mA: 200; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 15; MC OUTPUT-V: 5; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
Unregulated DC/DC Converter; In-V: 15; Out-V: 3.3; In V MIN: 13.5; In V MAX: 16.5; Out V MIN: 3.29999999999999; Out V MAX: 3.29999999999999; Out-mA: 303; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 15; MC OUTPUT-V: 3.3; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
Unregulated DC/DC Converter; In-V: 24; Out-V: 3.3; In V MIN: 21.6; In V MAX: 26.3999999999999; Out V MIN: 3.29999999999999; Out V MAX: 3.29999999999999; Out-mA: 303; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 24; MC OUTPUT-V: 3.3; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
1. Basic composition of automatic transmission There are many brands and models of automatic transmission, and their external shapes and internal structures are also different, but their composition i...
As the title says, please help me. It is best to provide the exact code. Thank you++ There is also an additional question. If you want to add a border to the dialog box, how can you do it? Thank you a...
When users choose ARM processors to develop embedded systems, choosing the right development tools can speed up the development process and save development costs. Therefore, an integrated development...
Due to business needs, we are recruiting WDK developers to engage in BDA architecture and WDK PCIe device driver development. The salary is generous and experience in WDK project development is requir...
As shown in the photo, an AM359 with screen, 90% new, the information is not very complete, currently only the Linux part, but it is enough. Not suitable for beginners. 300 yuan for a Samsung 4412, co...
In DOS, typing on the keyboard triggers an int 9 instruction. What about Windows? Does it also use int to trigger an interrupt? What is the interrupt number?...
In
circuit design,
current
measurement
is widely used, and the main fields are divided into three categories: in measurement,
the electric meter
is used to measure the curre...[Details]
When the WDP500-2A plane grating monochromator is used to test the emission wavelength of a high-power laser diode at different currents, the matching of the laser diode has the disadvantages of lo...[Details]
There are three types of mobile TV: one is based on analog TV broadcasting network, another is based on mobile communication network, and the other is based on digital broadcasting network. The f...[Details]
In this article, the high-performance DSP developed by TI can be used as an effective confidentiality method if it is applied to PC encryption cards.
As an effective network security solution,...[Details]
I. Introduction
In the field of power conversion, isolated converters (forward, flyback, and double-ended) with low output DC voltage all use MOSFET as the rectifier device. Since these devi...[Details]
Contact resistance
is the resistance to current flow through a closed pair of contacts. This type of measurement is performed on devices such as connectors,
relays
, and switches. The...[Details]
A standard cell
is an electrochemical
cell
used as a voltage reference standard in many electrical standards laboratories
. If properly maintained, standard cells are very stable. The ...[Details]
Product series: PB-B-RS232/485 interface (hereinafter sometimes referred to as "interface") is a product in the PROFIBUS bus bridge series.
The main purpose of the bridge series ...[Details]
1 Introduction to HART Protocol
HART (Highway Addressable Remote Transducer), an open communication protocol for addressable remote sensor high-speed channels, was launched by Rosemen in the U...[Details]
0 Introduction
With the rise and continuous improvement of the solid-state lighting industry, light-emitting diodes (LEDs) have become an alternative lighting technology and are gr...[Details]
Toyohashi University of Technology demonstrated electric field coupled wireless power supply technology using life-size car tires and roads at the wireless technology exhibition "Wireless Technolog...[Details]
1. When the slip speed regulating motor is undergoing frequency conversion and energy saving transformation, the original excitation box (referred to as the speed regulating box) and the original s...[Details]
This article will introduce a design method for a distributed control system used in a tracking car, which can perform distributed control of motor modules, sensor modules, and lighting control mod...[Details]
Introduction
In industrial control, speed measurement is often required. Generally, a contact tachometer is used. This tachometer must be placed against the center of the shaft to measure. It...[Details]
Our flight had just begun to descend when a gentleman sitting next to me turned to talk to me about engineering—he had seen me reading an engineering journal. The gentleman next to me said that he ...[Details]