Unregulated DC/DC Converter; In-V: 24; Out-V: 3.3; In V MIN: 21.6; In V MAX: 26.3999999999999; Out V MIN: 3.29999999999999; Out V MAX: 3.29999999999999; Out-mA: 303; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 24; MC OUTPUT-V: 3.3; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
Unregulated DC/DC Converter; In-V: 24; Out-V: 3.3; In V MIN: 21.6; In V MAX: 26.3999999999999; Out V MIN: 3.29999999999999; Out V MAX: 3.29999999999999; Out-mA: 303; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 24; MC OUTPUT-V: 3.3; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
The REM1 complements the existing board-mount REM3, REM6 and REM10 series by offering
a 1W medical grade unregulated DC/DC converter in a more compact SIP7 package. The REM1
features reinforced 5.2kVDC/1 minute isolation and 2MOPP/250VAC working voltage. The REM1 is
available with 3.3, 5, 12, 15 or 24V inputs and offers 3.3, 5 or 12V outputs with up to 85%
efficiency. The operating temperature range is -40°C up to +90°C. The converter is Class B EMC and
60601-1-2 (4th Ed.) medical EMC certified using a simple external LC filter. The converters are
fully certified to CB, IEC/EN and ANSI/AAMI 60601 third edition safety standards, RoHS2+ (10/10)
and REACH and come with a 5 year warranty.
rranty
Selection Guide
Part
Number
REM1-3.33.3S
REM1-3.305S
REM1-3.312S
REM1-053.3S
REM1-0505S
REM1-0512S
REM1-123.3S
REM1-1205S
REM1-153.3S
REM1-1505S
REM1-243.3S
REM1-2405S
nom. Input
Voltage
[VDC]
3.3
3.3
3.3
5
5
5
12
12
15
15
24
24
Output
Voltage
[VDC]
3.3
5
12
3.3
5
12
3.3
5
3.3
5
3.3
5
Output
Current
[mA]
303
200
84
303
200
84
303
200
303
200
303
200
Efficiency
typ.
(1)
[%]
78
81
85
79
80
84
78
81
77
81
76
80
Max. Capacitive
Load
(2)
[µF]
2200
2200
470
2200
2200
470
2200
2200
2200
2200
2200
2200
E314885
2MOPP
250VAC
IEC/EN60601-1 certified
ANSI/AAMI ES60601-1 certified
EN62368-1 certified
IEC/EN60601-1-2
EN55011
CB Report
Notes:
Note1: Efficiency tested by nominal input and full load at +25°C ambient.
Note2: Max Cap Load tested by nominal input and full resisitive load.
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
BASIC CHARACTERISTICS
Parameter
Internal Input Filter
3.3VDC
5VDC
nom. Vin= 12VDC
15VDC
24VDC
3.3VDC
5VDC
nom. Vin= 12VDC
15VDc
24VDC
continued on next page
www.recom-power.com
REV.: 2/2017
MED-1
Condition
Min.
2.97VDC
4.5VDC
10.8VDC
13.5VDC
21.6VDC
Typ.
Max.
Capacitor
3.63VDC
5.5VDC
13.2VDC
16.5VDC
26.4VDC
0VDC
40mA
25mA
12mA
10mA
7mA
Input Voltage Range
Maximum Reverse Voltage
Quiescent Current
REM1
DC/DC Converter
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
Parameter
Internal Operating Frequency
Minimum Load
Output Ripple and Noise
(3)
20MHz BW
Notes:
Note3: Measurements are made with a 0.1µF MLCC across output. (low ESR).
Series
Condition
Min.
Typ.
40kHz
0%
75mVp-p
Max.
Efficiency vs. Load
100
90
80
REM1-xx3.3S
100
90
80
70
REM1-xx05S
Efficiency [%]
Efficiency [%]
70
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
3.33.3
053.3
123.3
153.3
243.3
90
100
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
3.305
0505
1205
1505
2405
90
100
Load Current [A]
Load Current [A]
100
90
80
70
REM1-xx12S
Efficiency [%]
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
3.312
0512
90
100
Load Current [A]
Tolerance Envelope
REM1-3.33.3S
+12
Output Voltage [%]
REM1-2405S
Output Voltage [%]
+8
+3
V Nom.
+6
V Nom.
Typica
l
Load L
ine
+5
-0.5
-5
Typica
l
Load L
ine
+5
-0.5
-5
10
50
100
+Vout and -Vout Load Current [%]
MED-2
REV.: 2/2017
10
50
100
+Vout and -Vout Load Current [%]
www.recom-power.com
REM1
DC/DC Converter
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Load Regulation
low line to high line, full load
10% to 100% load
3.3Vout and 5Vout
12Vout
Series
Condition
Value
±5% max.
±1.2% typ. @ 1% of Vin
±8% typ. / ±12% max.
±5% typ. / ±8% max.
Accuracy vs. Load
30
25
20
REM1-xx3.3S
3.33.3
053.3
123.3
153.3
243.3
30
25
20
REM1-xx05S
3.305
0505
1205
1505
2405
Deviation [%]
15
10
5
0
-5
-10
0
10
20
30
40
50
60
70
80
90
100
Deviation [%]
15
10
5
0
-5
-10
0
10
20
30
40
50
60
70
80
90
100
Load Current [A]
Load Current [A]
REM1-xx12S
30
25
20
3.312
0512
Deviation [%]
15
10
5
0
-5
-10
0
10
20
30
40
50
60
70
80
90
100
Load Current [A]
PROTECTIONS
Parameter
Isolation Voltage
(4)
Isolation Resistance
Isolation Capacitance
Insulation Grade
Means of Protection
Creepage and Clearance
Notes:
Note4: For repeat Hi-Pot testing, reduce the time and/or the test voltage.
Note5: An input fuse is required if the mains supply is not over-current protected. Recommended fuse: T1A slow blow type
www.recom-power.com
REV.: 2/2017
MED-3
Type
I/P to O/P
tested for 1 minute
Value
5.2kVDC
4kVAC
10GΩ min.
25pF typ.
reinforced
250VAC working voltage
2MOPP
≥8mm
REM1
DC/DC Converter
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
ENVIRONMENTAL
Parameter
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
Operating Altitude
Operating Humidity
Pollution Degree
MTBF
Vibration
according to MIL-HDBK-217F, G.B.
+25°C
+85°C
according to IEC/EN60601-1
accroding to IEC/EN62368-1
non-condensing
Series
Condition
without derating (see graph)
Value
-40°C °C to +85°C
105°C
0.02%/°C typ.
3000m
5000m
5% - 95% RH max.
PD2
18200 x 10
3
hours
7500 x 10
3
hours
according to MIL-STD-202G standard
Derating Graph
(@ chamber and natural convection 0.1m/s)
100
80
60
40
30
20
0
-40
Output Power [%]
-20
0
20
40
60
Ambient Temperature [°C]
80 100
85 90
120
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Audio/video, information and communication technology equipment. Safety
requirements (CB Scheme)
Medical Electric Equipment, General Requirements for Saftey and Essential
Performance
Medical Electric Equipment, General Requirements for Safety and Essential
Performance
RoHs2+
Report / File Number
L0339m31-A-L
E314885-D1000-1/A0/C0-UL
E314885-D1000-1/A0/C0-CB
Standard
EN62368-1:2014
ANSI/AAMI ES60601-1:2012 + A2 2010/2012
CSA C22.2 No. 60601-1:14, 3rd Edition, 2014
IEC60601-1:2005 +AM1:2012
EN60601-1:2006 + A12:2014
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Medical electrical equipment - Part 1-2: General requirements for basic safety
and essential performance - Collateral standard: Electromagnetic compatibility
Industrial, scientific and medical equipment - Radio frequency disturbance
characteristics - Limits and methods of measurement
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Condition
Standard / Criterion
IEC60601-1-2:2014
EN60601-1-2:2015
with external filter
air: ±15kV; contact: ±8kV
3V/m
DC port: ±2kV
DC port: ±1kV
DC port: 6V
50Hz, 30A/m
EN55011, 2009+A1:2010, Class B
IEC61000-4-2:2008 , Criteria A
IEC61000-4-3:2006+A2:2010, Criteria A
IEC61000-4-4:2012, Criteria A
IEC61000-4-5:2014, Criteria B
IEC61000-4-6:2013, Criteria A
IEC61000-4-8:2009, Criteria A
continued on next page
MED-4
REV.: 2/2017
www.recom-power.com
REM1
DC/DC Converter
Specifications
(measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
EMC Filtering Suggestions according to EN55011
Series
C2
Component list Class B
Input Voltage
3.3VDC
5VDC
LOAD
L1
C1
4.7µF
C2
L1
22µH Choke
+Vin
C1
-Vin
12VDC
15VDC
24VDC
470pF/6kVDC
2.2µF
47µH Choke
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Material
Package Dimension (LxWxH)
Package Weight
Type
Case
Potting
PCB
Value
black plastic, (UL94 V-0)
silicone (UL94 V-0)
FR4 (UL94 V-0)
19.6 x 6.0 x 10.2mm
2.6g typ.
Dimension Drawing (mm)
embossed logo
19.6
6.0
0.50
4.1
1 2
6 7
Marking
Pin Connections
Pin #
Single
1
+Vin
2
-Vin
6
-Vout
7
+Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
Pin dimension:
±0.1mm
0.51
recommended footprint detail
10.2
1.00 Ø +0.15/-0
2.54
1.27
0.25
Bottom View
Top View
2.54
2.0
6x2.54= 15.24
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Storage Temperature Range
Storage Humidtiy
non-condensing
Type
tube
Value
520.0 x 16.0 x 9.3mm
25pcs
-55°C to +125°C
TBD
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
Unregulated DC/DC Converter; In-V: 24; Out-V: 3.3; In V MIN: 21.6; In V MAX: 26.3999999999999; Out V MIN: 3.29999999999999; Out V MAX: 3.29999999999999; Out-mA: 303; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 24; MC OUTPUT-V: 3.3; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
DC-DC Unregulated Power Supply Module, 1 Output, 1W, Hybrid, SIP-7/4
DC-DC Unregulated Power Supply Module, 1 Output, 1W, Hybrid, SIP-7/4
Unregulated DC/DC Converter; In-V: 05; Out-V: 12; In V MIN: 4.5; In V MAX: 5.5; Out V MIN: 12; Out V MAX: 12; Out-mA: 84; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 5; MC OUTPUT-V: 12; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
Unregulated DC/DC Converter; In-V: 15; Out-V: 05; In V MIN: 13.5; In V MAX: 16.5; Out V MIN: 5; Out V MAX: 5; Out-mA: 200; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 15; MC OUTPUT-V: 5; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
Unregulated DC/DC Converter; In-V: 15; Out-V: 3.3; In V MIN: 13.5; In V MAX: 16.5; Out V MIN: 3.29999999999999; Out V MAX: 3.29999999999999; Out-mA: 303; Isolation: 5.2kV; Output: single; Power Watts or Amps: 1W; Package: SIP7; Short Circuit Protec: No; MC INPUT-V: 15; MC OUTPUT-V: 3.3; Length: 19.6 mm; Width: 6 mm; Height: 10.2 mm; Packaging Type: Tube
DC-DC Unregulated Power Supply Module, 1 Output, 1W, Hybrid, SIP-7/4
The standard process is to perform timing analysis after DC and then PR. If the system frequency is not high, is it necessary? The highest frequency reported in the FPGA environment is more than 120M,...
[backcolor=white][color=#000000]In the software development process of 32-bit embedded systems, byte alignment is very important. Let's take the ARM processor and ADS1.2 development environment as exa...
I have an idea for a scenario: people, convoys, and even animals, carrying Zigbee terminals, to achieve self-organizing networks, quantity monitoring, and early warning. I want to achieve this functio...
[i=s] This post was last edited by paulhyde on 2014-9-15 09:14 [/i] Does anyone have the information of PT2267/2272 or the finished module information?...
Why does my protues software often fail to run? It cannot be opened after using it a few times. What's going on? It's very troublesome. Every time it breaks down, I have to uninstall and reinstall it....
1. Overview
Will passive devices
produce nonlinear intermodulation distortion? The answer is yes! Although there is no systematic theoretical analysis, it has been found in engineerin...[Details]
0. Introduction
In daily life, we often see some special-purpose vehicles. When these vehicles pass through intersections, they often obtain the right of way at intersections by temporarily op...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
Abstract: In order to generate a stable excitation signal, the design of a digital frequency synthesizer is implemented on FPGA using Verilog hardware language. The design includes accumulator, wav...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
My colleague and I spent the day chatting in the hotel bar. We had met with several customers. We were both wondering how come these engineers we were meeting knew almost nothing about analog techn...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
LED lamps and bulbs are now rapidly replacing incandescent, halogen and CFL (compact fluorescent lamp) light sources in many general lighting applications. Flyback DC/DC converters are the power su...[Details]
In the analysis of electronic circuits, static analysis (also known as DC analysis) is the basis of circuit analysis. However, it is well known that electronic components are nonlinear, so the anal...[Details]
RS-422 and RS-485 are both serial data interface standards, which were developed and published by the Electronic Industries Association (EIA). RS-422 defines a balanced communication interface with a ...[Details]
VP2188 is a color STN LCD module produced by Jingdian Pengyuan. This module is a dot matrix transmissive color STN display screen with a color scale of 65 k colors and white LED backlight. Its core...[Details]
This controller uses PIC16C54 single-chip microcomputer as the controller, and it is very easy to use: just connect a telephone line to the loudspeaker through the controller, and you can rem...[Details]
1. Disadvantages of choosing too high a voltage level
Choosing too high a voltage level will result in too high an investment and a long payback period. As the voltage level increases, the...[Details]
OC faults may be the most frequent and the most frequent of all faults in the inverter. They alarm during the startup process, during the shutdown process, during operation, and even when powered o...[Details]