SCIHP1367
SMD POWER INDUCTORS
MARKING
●
Features
1. Lowest DCR/uH in this small package size.
2. Frequency range up to 5.0MHZ.
3. -55℃ to +125℃ operating temperature.
4. Handles high transient current spikes without saturation.
5. Composite construction providing extremely low buzz noise.
ELECTRICAL CHARACTERISTICS
Part Number
Inductance
Test
(uH)
Frequency
(1)
Saturation Temperature
DC
Current
Current
(4)
Resistance
(3)
(Ω
MAX)
(A)
(A)
(2)
100
SCIHP1367 Inductance decrease by current
BCIHP1367 Inductance by current
Inductance (µH)
Inductance (uH)
SCIHP1367-2R2M
SCIHP1367-3R3M
SCIHP1367-4R7M
SCIHP1367-5R6M
SCIHP1367-6R8M
SCIHP1367-8R2M
SCIHP1367-100M
2.2
3.3
4.7
5.6
6.8
8.2
10
200KHZ
200KHZ
200KHZ
200KHZ
200KHZ
200KHZ
200KHZ
4.2m
6.8m
11.2m
11.5m
14.9m
16.6m
18.5m
33
29
25
24
16.5
16
15.5
20
15
13.5
12
11.5
10.5
10
10
100
5R
6
2R
2
1. 0
0
100
1000
10000
DC current (mA)
DC current(mA)
100000
SCIHP1367 Temperature
rise
current
BCIHP1367 Temperature
rise by
by current
Temperature rise °C
Temperature rise
℃
80
70
60
50
40
30
20
10
0
5000
100
5R
6
2R
2
10000 15000
20000 25000 30000
DC current(mA)
DC current (mA)
(1). Inductance tolerance
±20%
tested at 0.25V, 0ADC and 25℃
(2). DCR measured at 25℃.
(3). The DC current at which the inductance decreases by 20% from its initial value.
(4). The DC current that results in a 40℃ temperature rise from 25℃ ambient
(*). Part temperature (ambient + temp rise) should not exceed 125℃ under worst case operating conditions. Circuit design, component
placement, PCB trace size and thickness, airflow and other cooling provisions may affect the temperature of the part. Part temperature
should be verified in the end application.
Click here for
QUANTITY PER REEL & PACKING INFORMATION
Custom versions available upon request.
©
2011 Signal Transformer –Specification subject to change without notice. 07.11
www.signaltransformer.com
500 Bayview Avenue, Inwood, NY 11096
Toll Free 866-239-5777 • Tel 516-239-5777 • Fax 516-239-7208
Sales@signaltransformer.com
•
techhelp@signaltransformer.com
177