EEWORLDEEWORLDEEWORLD

Part Number

Search

MT036A120M010TP

Description
1-OUTPUT 180 W DC-DC REG PWR SUPPLY MODULE
Categoryaccessories   
File Size486KB,11 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Compare View All

MT036A120M010TP Overview

1-OUTPUT 180 W DC-DC REG PWR SUPPLY MODULE

MIL-COTS MT036 SERIES VTM
TM
Current Multiplier
Features
-55°C to 100°C baseplate operation
Isolated 1 to 50 Vout
High density
Small footprint
Size:
1.91 x 1.09 x 0.37 in
48,6 x 27,7 x 9,5 mm
3 MHz effective switching frequency
Low weight – 1.10 oz (31.3 g)
1 µs transient response
Up to 96.5% efficiency
ZVS / ZCS Sine Amplitude Converter
Product Overview
The VI BRICK VTM Current Multiplier
provides extremely fast, efficient, and quiet
fixed ratio voltage division (or current
multiplication). With twelve voltage division
ratios from 1:1 to 1:32, the isolated
VI BRICK VTM provides the user with the
flexibility to supply up to 100 A or 120 W at
any output voltage from 1 to 50 Vdc in a
package occupying ~ 2 square inches.
The Military COTS VI BRICK VTMs are
optimized for use with the Military
Pre-Regulator Module to implement a
Factorized Power Architecture (FPA).
Together, the PRM
TM
+ VTM set provides
the full functionality of a DC-DC converter,
but with breakthrough performance and
flexibility in a rugged, miniature package.
The companion VI BRICK PRM for the MT036
family of VI BRICK VTMs is the 28 Vdc input
MR028A036M012FP, which operates from
an input range of 16-50 Vdc (the data sheet
is available at vicorpower.com). The VTM can
also be used as a standalone POL product.
By factorizing the DC-DC power conversion
into its essential elements – isolation and
transformation on the one hand, and the
output voltage control and regulation on
the other – and arranging those functions
in a sequence that maximizes system
performance, FPA offers a fundamentally
new and significantly improved approach to
power conversion.
The VI BRICK VTM’s fast dynamic response
and low noise eliminate the need for bulk
capacitance at the load, substantially
increasing the POL density while improving
reliability and decreasing cost.
Absolute Maximum Ratings
Parameter
+In to -In
+In to -In
PC to -In
VC to -In
+Out to -Out
Isolation voltage
Output current
Peak output current
Output power
Peak output power
Operating temperature
Storage temperature
Values
-1.0 to 60
100
-0.3 to 7.0
-0.3 to 19.0
Model specific
2,250
Model specific
1.5 • Iout
120
180
-55 to +100
-65 to +125
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
A
A
W
W
°C
°C
Notes
For 100 ms
Input to output
Continuous
For 1 ms
Continuous
For 1 ms
M-Grade; baseplate
M-Grade
Note:
Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any other conditions
in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability.
Voltage Transformation Module
MT036 SERIES
vicorpower.com
Rev. 1.0
Page 1 of 11

MT036A120M010TP Related Products

MT036A120M010TP MT036 MT036A011M100FP MT036A022M055FP MT036A060M020FP MT036A072M017FP MT036A120M010FP MT036A180M007FP
Description 1-OUTPUT 180 W DC-DC REG PWR SUPPLY MODULE 1-OUTPUT 180 W DC-DC REG PWR SUPPLY MODULE 1-OUTPUT 180 W DC-DC REG PWR SUPPLY MODULE 1-OUTPUT 180 W DC-DC REG PWR SUPPLY MODULE 1-OUTPUT 180 W DC-DC REG PWR SUPPLY MODULE 1-OUTPUT 180 W DC-DC REG PWR SUPPLY MODULE 1-OUTPUT 180 W DC-DC REG PWR SUPPLY MODULE 1-OUTPUT 180 W DC-DC REG PWR SUPPLY MODULE

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1240  860  590  433  77  25  18  12  9  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号