EEWORLDEEWORLDEEWORLD

Part Number

Search

L42-B0-22-410-46B-KG

Description
Magnetic Circuit Breaker,
CategoryCircuit protection    Circuit protection   
File Size2MB,8 Pages
ManufacturerCarling Technologies
Environmental Compliance
Download Datasheet Parametric View All

L42-B0-22-410-46B-KG Overview

Magnetic Circuit Breaker,

L42-B0-22-410-46B-KG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerCarling Technologies
Reach Compliance Codecompli
Circuit protection typeMAGNETIC CIRCUIT BREAKER
L-Series
Circuit Breaker
Available with Current Transformer
The L-Series high performance, compact hydraulic-
magnetic circuit breaker is ideally suited for the rigors and
confined spaces found in today’s telecom/datacom power
distribution units and rack systems. It provides best in class
performance in an innovative low profile, space saving
package complementing the overall spatial objectives
required by telecommunications and data-communications
systems designers in their quest to reduce the overall size
of equipment, while increasing transmission capacity.
The optional current transformer allows outlet metering
and monitoring of power usage thus facilitating load
adjustments and maximizing efficiency.
Further, a patent
pending flush rocker actuator design and optional push-to-
reset guard offers additional protection against accidental
switching.
Number of poles: 1-3. Maximum current and voltage
ratings: .2-32A, 120/240-240VAC. Maximum interrupting
capacity: 5000 Amps
Applications:
Š
Telecom/Datacom Industry
– Power Distribution Units
– Data Servers
– Data Storage
Product Highlights:
Š
Optional current transformer
Š
Ultra low profile design saves valuable space
Š
Optional handle guard actuator
Š
UL 489 LISTED Branch Circuit breaker
Š
Designed for worldwide datacenter
compatibility with up to 240VAC ratings
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
I want to ask you a question about the ROM file system?
I can now boot the SD card as the root file system, but I want to use a folder in the SD card as the root file system instead of the entire SD card. How can I do this?...
youliam Embedded System
E-book
Qiu's Circuits 5th Edition...
jslytb Embedded System
Applications of RF Transformers
Applications of RF Transformers RF transformers are widely used in electronic circuitsTransformer Circuits and Impedance Relationships When the signal current passes through the primary winding, it cr...
btty038 RF/Wirelessly
Application of high power stepper motor drive power supply
BS308, BS312 five-step high-power stepper motor drive system, motor working current is 8A, 12A two-axis drive...
frozenviolet Power technology
STC89C52RC~Independent key to send data
17 independent buttons are designed to send data. P1^0 to P1^7 and P0^0 to P0^6 are set as independent buttons. Press to send data, and press again to send data. However, P1^0 to P1^7 can send data no...
ml0943 51mcu
I simulated the speed system on the 51 MCU side, but there is no image on the digital tube. I don’t know what’s wrong - so sad. . .
//The main program starts. Within a certain measuring time T, the number of pulses M generated by the pulse generator (instead of the input pulse) is measured to measure the speed. // ORG 0000H AJMP M...
G1162950608 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 126  1071  2922  521  2636  3  22  59  11  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号