EEWORLDEEWORLDEEWORLD

Part Number

Search

DI3-72AV5AD0XX

Description
Panel Meters and Controllers AC Ammeter or Voltmeter
File Size59KB,3 Pages
ManufacturerETC2
Download Datasheet Compare View All

DI3-72AV5AD0XX Overview

Panel Meters and Controllers AC Ammeter or Voltmeter

Panel Meters and Controllers
AC Ammeter or Voltmeter
Type DI3-72 AV1/AV5
3-dgt µP-based indicator for
AC currents or voltages
Selectable CT/VT primary range
Panel mounting
72 x 72 mm
Degree of protection (front): IP 50 (IP 65 on request)
Product Description
3-dgt µP-based meter with
double input for AC currents
or voltages. With 20 selectable
primary CT/VT ranges. The
housing is for panel mounting
and ensures a degree of
protection (front) of IP 50 (IP
65 on request).
Ordering Key
Model
Range code
Measurement
Power supply
Setpoints
Options
DI3-72AV5AD0XX
Type Selection
Range code
AV1:
AV5:
1 A/100 V
Standard cur-
rent/voltage
5 A/500 V
Standard cur-
rent/voltage
See Range Table
Power supply
A:
B:
C:
D:
24 VAC, -15% +10%,
50/60 Hz
48 VAC, -15% +10%,
50/60 Hz
115 VAC, -15% +10%,
50/60 Hz
230 VAC, -15% +10%,
50/60 Hz (standard)
1)
1)
1)
Options
XX:
EX:
None (standard)
Degree of protection
IP 65
1)
Power supply on request
Input Specifications
Rated input
5A/500 VAC, 45 to 400 Hz
(1A/100 VAC on request)
Overload protection
Cont. Current:
Voltage:
For 1 s Current:
Voltage:
Accuracy
(@ 25°C ± 5°C, R.H.
60%)
Temperature drift
Display
Sampling rate
Indication
Max.
Min.
500 VAC range
Other ranges
Over range
Input range selection
Decimal point position
1.2 x rated input
1.2 x rated input
5 x rated input
2 x rated input
± 0.5% f.s., ± 1 dgt
± 350 ppm/ºC
7-segment LED, h 14.2 mm,
3 digits
1 time/s
999
000
Scalesuppressionupto 5% f.s.
Scalesuppressionupto 3% f.s.
EEE
DIP-switch selectable
DIP-switch selectable
General Specifications
Operating temperature
Storage temperature
Insulation reference voltage
Dielectric strength
Noise rejection
CMRR
EMC
0° to 50°C (32° to 122°F)
(R.H. < 90% non-condensing)
-10° to 60°C (14° to 140°F)
(R.H. < 90% non-condensing)
300 V to ground
4000 V for 1 minute
rms
rms
Safety standards
Connector
Housing
Dimensions
Material
Degree of protection
Weight
Approvals
100 dB, 40 to 60 Hz.
IEC 60801-2, IEC 60801-3,
IEC 60801-4 (level 2),
EN 50 081-1, EN 50 082-1.
EN 61 010-1, IEC 61010-1,
VDE 0411
Screw-type
72 x 72 x 75 mm
ABS,
self-extinguishing: UL 94 V-0
Front: IP 50 (IP 65 on request)
Approx 250 g
CE, CSA
Specifications are subject to change without notice
1

DI3-72AV5AD0XX Related Products

DI3-72AV5AD0XX DI3-72AV5AD0EX DI372AV5
Description Panel Meters and Controllers AC Ammeter or Voltmeter Panel Meters and Controllers AC Ammeter or Voltmeter Panel Meters and Controllers AC Ammeter or Voltmeter

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2287  1984  1687  2733  1827  47  40  34  56  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号