MEDER electronic
CHARACTERISTICS
•
•
•
•
Glass length of 16.5 mm and diameter of 2.8 mm
Normally open 1 Form A contact
Carry current up to 1 A
300 VAC breakdown voltage
KSK-1A71/6-...
All dimensions in mm [inches]
DIMENSIONS
16.5
[0.650]
ø
0.5
[0.019]
ø
2.8
[0.110]
22.05
[0.868]
44.1
[1.736]
CONTACT DATA
All Data at 20
o
C
Contact Ratings
Switching Power *
Switching Voltage
Switching Voltage
Switching Current
Carry Current
Static Contact Resistance
Dynamic Contact Resistance
Insulation Resistance cross Contacts
Breakdown Voltage
Release Time incl. Bounce
Release Time
Capacitance
Test Coil **
Standard AT range
Switch Model
→
Contact Form
→
Conditions
Any combination of V and A not to
exceed their individual max.’s
DC
AC
DC or peak AC
DC or peak AC
at 0.5 V & 10 mA
measured w/ 0.5 V & 50 mA, 1.5 ms
after closure
100 Volts applied
> 60 sec.
40 % overdrive
measured with/ no coil excitation
at 10 kHz across contact
KSK-1A71/6-...
Form A
Min.
Typ.
Max.
10
320
230
0.4
1.0
100
200
1
300
0.8
0.05
0.3
KMS-01
15
60
AT
Units
W
VDC
VAC
A
A
mΩ
mΩ
GΩ
VAC
ms
ms
pF
Environmental Data
Shock Resistance
Vibration Resistance
Ambient Temperature
Stock Temperature
Soldering Temperature
1/2 sine wave for 11 ms
10 - 2000 Hz
max. 10
o
C / minute allowance
max. 10
o
C / minute allowance
5 sec. dwell
-20
-55
50
20
130
130
260
g
g
o
C
C
C
o
o
Note: The indicated electric data are maximum values can vary downwards when using a more sensitive switch.
* For life expectancy see our test section on Page 112.
** See our test section on Page 116.
ORDER INFORMATION
Series
KSK -
Options
Contact Form
1A
Switch Model
71/6 -
AT Range
(between)
xxxx
20 -70
Part Number Example -
KSK - 1A71/6 - 2030
2030
is the pull in AT range (Any AT can be ordered
between 20 & 30 in a minimum range of +/-2 AT)
www.meder.com