EEWORLDEEWORLDEEWORLD

Part Number

Search

54122-813-31-1150R

Description
Board Connector, 62 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Kinked Leads Terminal, Locking, Black Insulator, Receptacle
CategoryThe connector    The connector   
File Size107KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Download Datasheet Parametric View All

54122-813-31-1150R Overview

Board Connector, 62 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Kinked Leads Terminal, Locking, Black Insulator, Receptacle

54122-813-31-1150R Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerAmphenol
Objectid306297984
Reach Compliance Codecompliant
ECCN codeEAR99
body width0.19 inch
subject depth0.453 inch
body length3.1 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU ON NI
Contact completed and terminatedTin/Lead (Sn/Pb) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Insulation resistance5000000000 Ω
Insulator colorBLACK
insulator materialTHERMOPLASTIC
JESD-609 codee0
Manufacturer's serial number54122
Plug contact pitch0.1 inch
Match contact row spacing0.1 inch
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB contact patternRECTANGULAR
PCB contact row spacing2.54 mm
Plating thickness15u inch
Rated current (signal)3 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.12 inch
Terminal pitch2.54 mm
Termination typeSOLDER KINKED LEADS
Total number of contacts62
PDM: Rev:K
STATUS:
Released
Printed: Mar 10, 2011
.
Altium Designer 09 software learning materials
Altium Designer Software Learning Materials...
吴超伟 MCU
Can vxworks compile a dynamic library, that is, can it generate a .so file?
Can vxworks compile a dynamic library, that is, can it generate a .so file? I am using two compilation environments, tornado2.2 and Wind River. Previously, we compiled libraries by writing static libr...
zyjnh005 Real-time operating system RTOS
Strain Gauges
A dynamic force is loaded on one end of the cantilever beam, and a strain gauge is used to measure the strain of the cantilever beam. To ensure that the strain gauge can work normally, what is the max...
a问问 Sensor
Discussion on AC and DC conversion issues
I hope all the power experts will think about the four basic power conversion problems: DC to DC, AC to DC, DC to AC, and AC to AC, including how to convert, what devices or components to use for conv...
piggyfeng Power technology
51 MCU floating point calculation error problem
I would like to ask, after using stc89c52 to do floating point calculations, there is sometimes an error of 0.01 when taking 2 decimal places. What is the accuracy of floating point calculations of si...
zzxuzz 51mcu
MSP430F5529 Power Management Module
Power management and monitoring is a very complex part that is difficult to master. It not only involves the selection of source mode, but also involves complex interrupts and how to handle interrupts...
Jacktang Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2673  2495  2717  473  962  54  51  55  10  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号