Features :
Universal AC input / Full range
GS18U
series
No load power consumption<0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 pole USA plug
Class
power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / BSMI / CB / FCC
Pass LPS
2 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
OUTPUT
VOLTAGE TOLERANCE
Note.4
LINE REGULATION
LOAD REGULATION
Note.5
Note.6
GS18U05-P1J GS18U07-P1J GS18U09-P1J GS18U12-P1J GS18U15-P1J GS18U18-P1J GS18U24-P1J GS18U28-P1J GS18U48-P1J
GS18U05
Note.2
5V
GS18U07
7.5V
2.0A
0 ~ 2.0A
15W
80mVp-p
5.0%
1.0%
5.0%
GS18U09
9V
2.0A
0 ~2.0A
18W
80mVp-p
5.0%
1.0%
5.0%
GS18U12
12V
1.50A
0 ~ 1.50A
18W
80mVp-p
3.0%
1.0%
3.0%
GS18U15
15V
1.20A
0 ~ 1.20A
18W
100mVp-p
3.0%
1.0%
3.0%
GS18U18
18V
1.0A
0 ~ 1.0A
18W
150mVp-p
3.0%
1.0%
3.0%
GS18U24
24V
0.75A
0 ~ 0.75A
18W
180mVp-p
2.0%
1.0%
2.0%
GS18U28
28V
0.64A
0 ~ 0.64A
18W
240mVp-p
2.0%
1.0%
2.0%
GS18U48
48V
0.375A
0 ~ 0.375A
18W
240mVp-p
2.0%
1.0%
2.0%
3.0A
0 ~ 3.0A
15W
5.0%
1.0%
5.0%
RIPPLE & NOISE (max.)
Note.3
50mVp-p
SETUP, RISE, HOLD UP TIME
500ms, 20ms, 50ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 7)
EMC EMISSION
OTHERS
MTBF
DIMENSION
PACKING
PLUG
CABLE
47 ~ 63Hz
79.5%
0.5A / 100VAC
25A / 115VAC
0.25mA / 240VAC
82%
83%
500ms, 20ms, 15ms/115VAC at full load
85%
85%
85%
86%
86.5%
87%
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 150% rated output voltage
Protection type : Clamp by zener diode, output short
0 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, BSMI,CNS14336 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to FCC PART 15 / CISPR22 class B, CNS13438 class B
500Khrs min. MIL-HDBK-217F(25
79*54*33mm (L*W*H)
210g ; 60pcs / 13.5kg / CARTON
See page2
See page2
)
CONNECTOR
NOTE
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
File Name:GS18U-SPEC 2011-06-14

GS18U15 Related Products

GS18U15 GS18U09 GS18U18 GS18U28 GS18U_11
Description 10~18WAC-DC Single Output Wall-mounted type 10~18WAC-DC Single Output Wall-mounted type 10~18WAC-DC Single Output Wall-mounted type 10~18WAC-DC Single Output Wall-mounted type 15~18WAC-DC Single Output Wall-mounted type
How to play rmvb movies in windows ce.net? Is there any software that can install and play them?
How to play rmvb movies in windows ce.net? Is there any software that can install and play them?...
microwave1 Embedded System
[Modesim Problem] Problems encountered when simulating project files with altera ip cores using modelsim se
I would like to ask an expert for help . When I simulate a project with an IP core, there is a vhd file with the IP core under the top-level file of this project, which can be called ip.vhd, and two f...
eeleader FPGA/CPLD
Comparison of ACPI and APM power management modes
APM 1.0 & 1.1: BIOS performs power management; APM 1.2: The operating system defines the power management time, which is executed by the BIOS; ACPI: The BIOS collects hardware information and defines ...
zbz0529 Power technology
Contents and characteristics of electrical testing
Electrical testing refers to all tests performed using electrical technology and tests performed on electrical systems and equipment (motors, electrical appliances, etc.). Electrical testing usually i...
一世轮回 Integrated technical exchanges
Generation of static electricity
Matter is composed of molecules, which are composed of atoms. Atoms are composed of negatively charged electrons and positively charged protons. Under normal conditions, the number of protons in an at...
wangqingtao Power technology
When the stc89c52 microcontroller uses external interrupt 0, can't ET1 be set to 1?
I used protues to simulate and found that when I used external interrupt 0 and turned on the overflow interrupt of timer 1 (ET1=1), the external interrupt would not be triggered and could only be set ...
赵怡彬 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2741  2354  505  1523  1278  56  48  11  31  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号