15~18W AC-DC Single Output Wall-mounted type
Features :
Universal AC input / Full range
GS18U
series
No load power consumption<0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 pole USA plug
Class
power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / BSMI / CB / FCC
Pass LPS
2 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
OUTPUT
VOLTAGE TOLERANCE
Note.4
LINE REGULATION
LOAD REGULATION
Note.5
Note.6
GS18U05-P1J GS18U07-P1J GS18U09-P1J GS18U12-P1J GS18U15-P1J GS18U18-P1J GS18U24-P1J GS18U28-P1J GS18U48-P1J
GS18U05
Note.2
5V
GS18U07
7.5V
2.0A
0 ~ 2.0A
15W
80mVp-p
5.0%
1.0%
5.0%
GS18U09
9V
2.0A
0 ~2.0A
18W
80mVp-p
5.0%
1.0%
5.0%
GS18U12
12V
1.50A
0 ~ 1.50A
18W
80mVp-p
3.0%
1.0%
3.0%
GS18U15
15V
1.20A
0 ~ 1.20A
18W
100mVp-p
3.0%
1.0%
3.0%
GS18U18
18V
1.0A
0 ~ 1.0A
18W
150mVp-p
3.0%
1.0%
3.0%
GS18U24
24V
0.75A
0 ~ 0.75A
18W
180mVp-p
2.0%
1.0%
2.0%
GS18U28
28V
0.64A
0 ~ 0.64A
18W
240mVp-p
2.0%
1.0%
2.0%
GS18U48
48V
0.375A
0 ~ 0.375A
18W
240mVp-p
2.0%
1.0%
2.0%
3.0A
0 ~ 3.0A
15W
5.0%
1.0%
5.0%
RIPPLE & NOISE (max.)
Note.3
50mVp-p
SETUP, RISE, HOLD UP TIME
500ms, 20ms, 50ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 7)
EMC EMISSION
OTHERS
MTBF
DIMENSION
PACKING
PLUG
CABLE
47 ~ 63Hz
79.5%
0.5A / 100VAC
25A / 115VAC
0.25mA / 240VAC
82%
83%
500ms, 20ms, 15ms/115VAC at full load
85%
85%
85%
86%
86.5%
87%
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 150% rated output voltage
Protection type : Clamp by zener diode, output short
0 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, BSMI,CNS14336 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to FCC PART 15 / CISPR22 class B, CNS13438 class B
500Khrs min. MIL-HDBK-217F(25
79*54*33mm (L*W*H)
210g ; 60pcs / 13.5kg / CARTON
See page2
See page2
)
CONNECTOR
NOTE
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
File Name:GS18U-SPEC 2011-06-14