EEWORLDEEWORLDEEWORLD

Part Number

Search

2641LPC1/43500L12V

Description
Rocker Switch, On-off, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2641LPC1/43500L12V Overview

Rocker Switch, On-off, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2641LPC1/43500L12V Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator colorYELLOW
Actuator length0.394 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
Other features12V FILAMENT LAMP
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialCOPPER
Center contact platingSILVER
Contact (AC) maximum rated power R load0.16HP@250VAC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@24VDC
Contact functionON-OFF
Contact resistance0.01 mΩ
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialCOPPER
End contact platingSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Microcontroller C Language Tutorial (Part 3)
Today we are talking about the fourth lesson that needs to be downloaded....
rain MCU
, I found that this book has many errors
I have read more than a dozen examples for a few days, but most of them have errors in the code. They are not correct when I write them down on the board. For example, I found that there are six error...
石玉 Microcontroller MCU
Help: After the computer was infected, ghost was performed, and the partition was changed. When repairing the partition, there was a sudden power outage and the desktop could not be displayed. Now the desktop shows invalid partition table.
After the computer was infected, ghost was performed and the partition was changed. When repairing the partition, there was a sudden power outage and the desktop could not be displayed. Now invalid pa...
zuigui111 Embedded System
GTM900 TCP connection data packet loss?
GTM900 TCP packet loss problem.. When GTM900 sends data using IPSEND in TCP, it sends 10 data but only receives 6 data. The delay time is 1S. I don't know why?...
ibmibm Embedded System
LF2407a's PWM+ADC+PID cannot adjust the duty cycle
I use LF2407A to control PWM duty cycle through PID to stabilize the output voltage at 3V, but the duty cycle does not change with the voltage of ADCIN0 input. I don't know where the problem is? Pleas...
helh Microcontroller MCU
Introduction to Machine Vision Technology
Machine vision is a comprehensive technology, including image processing, mechanical engineering technology, control, electric light source lighting, optical imaging, sensors, analog and digital video...
三合三智能科技 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1547  2194  2702  2834  887  32  45  55  58  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号