Provides efficient and craft-friendly cable preparation
SZ-stranded, loose tube design
Isolates fibers from installation and environmental rigors
and facilitates mid-span access
Dielectric central strength member
No preferential bend and requires no bonding or ground-
ing
Medium-density polyethylene jacket
Makes cable rugged and durable while being flexible and
easy to strip
ALTOS
®
all-dielectric cables, enhanced are lightweight
cables designed for duct and aerial (lashed) installation.
The loose tube design provides stable performance over
a wide temperature range and is compatible with any
telecommunications-grade optical fiber.
Standards
Design and Test Criteria
ANSI/ICEA S-87-640
Telcordia GR-20
RDUP PE-90
ALTOS All-Dielectric Cables, 72 Fibers, Enhanced
| Photo PIM1288
Family Spec Sheet 0002_NAFTA_AEN
Page 1 | Revision date 2014-08-08
ALTOS All-Dielectric Cables, 288 Fibers, Enhanced
| Photo PIM1293
ALTOS
®
All-Dielectric Cables,
12-432 Fibers, Enhanced
Ripcord
Dielectric Central
Element
Buffer
Tube
Water-Swellable
Tape
Fiber
Polyethylene (PE)
Outer Jacket
Ripcord
Dielectric Central
Element
Buffer
Tube
Water-Swellable
Tape
Fiber
Water-Swellable
Tape
Polyethylene (PE)
Outer Jacket
ALTOS All-Dielectric Cables, 72 Fibers, Enhanced
| Photo PIM2186
ALTOS All-Dielectric Cables, 288 Fibers, Enhanced
| Photo PIM2191
Specifications
Temperature Range
Storage
Installation
Operation
-40 °C to 70 °C (-40 °F to 158 °F)
-30 °C to 70 °C (-22 °F to 158 °F)
-40 °C to 70 °C (-40 °F to 158 °F)
*
Note: Corning recommends storing cable in a proper temperature environment prior to installation to allow the cable temperature to meet installation tempera-
ture range specifications for best installation results.
Max. Tensile Strength, Short-Term
Max. Tensile Strength, Long-Term
2700 N (600 lbf)
890 N (200 lbf)
Mechanical Characteristics Cable
Fiber Count Product
Type
12 - 72
96
144
192 - 216
Dielectric
Dielectric
Dielectric
Dielectric
Maximum
Fibers per
Tube
12
12
12
12
Number of
Tube Posi-
tions
6
8
12
18
Number
of Active
Tubes
1-6
8
12
16 - 18
Weight
Nominal
Outer Dia-
meter
10.5 mm
(0.41 in)
12.2 mm
(0.48 in)
15.8 mm
(0.62 in)
16.0 mm
(0.63 in)
Min. Bend
Radius
Installation
158 mm
(6.2 in)
183 mm
(7.2 in)
237 mm
(9.3 in)
240 mm
(9.4 in)
Min. Bend
Radius
Operation
105 mm
(4.1 in)
122 mm
(4.8 in)
158 mm
(6.2 in)
160 mm
(6.3 in)
80 kg/km
(54 lb/1000 ft)
108 kg/km
(72 lb/1000 ft)
177 kg/km
(119 lb/1000 ft)
169 kg/km
(113 lb/1000 ft)
Family Spec Sheet 0002_NAFTA_AEN
Page 2 | Revision date 2014-08-08
ALTOS
®
All-Dielectric Cables,
12-432 Fibers, Enhanced
Mechanical Characteristics Cable
Fiber Count Product
Type
288
360 - 432
Dielectric
Dielectric
Maximum
Fibers per
Tube
12
12
Number of
Tube Posi-
tions
24
36
Number
of Active
Tubes
24
30 - 36
Weight
Nominal
Outer Dia-
meter
18.2 mm
(0.72 in)
21.2 mm
(0.83 in)
Min. Bend
Radius
Installation
273 mm
(10.7 in)
318 mm
(12.5 in)
Min. Bend
Radius
Operation
182 mm
(7.2 in)
212 mm
(8.3 in)
226 kg/km
(152 lb/1000 ft)
288 kg/km
(194 lb/1000 ft)
Chemical Characteristics
RoHS
Free of hazardous substances according to RoHS 2002/95/
EG
Transmission Performance
Multimode
Fiber Core Diameter
(
µm
)
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Serial 1 Gigabit Ethernet
(
m
)
Serial 10 Gigabit Ethernet
(
m
)
Min. Overfilled Launch (OFL)
Bandwidth
(
MHz*km
)
Minimum Effective Modal
Bandwidth (EMB)
(
MHz*km
)
62.5
OM1
K
30
850/1300
3.4/1.0
300/550
33/-
200/500
220/-
50
OM2
T
31
850/1300
3.0/1.0
750/500
150/-
700/500
950/-
50
OM3
T
80
850/1300
3.0/1.0
1000/600
300/-
1500/500
2000/-
50
OM4
T
90
850/1300
3.0/1.0
1100/600
550/-
3500/500
4700/-
Family Spec Sheet 0002_NAFTA_AEN
Page 3 | Revision date 2014-08-08
ALTOS
®
All-Dielectric Cables,
12-432 Fibers, Enhanced
Single-mode
Fiber Name
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Typical Attenuation*
(
dB/km
)
Fiber Name
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Typical Attenuation*
(
dB/km
)
SMF-28e+
®
fiber
G.652.D
E
00
1310/1383/1550
0.35/0.35/0.25
0.33/0.33/0.19
LEAF
®
G.655
F
01
1310/1383/1550
-/-/0.25
-/-/0.19
SMF-28e+
®
fiber
G.652.D
E
01
1310/1383/1550
0.4/0.4/0.3
0.33/0.33/0.19
SMF-28
®
ULL
G.652
P
19
1310/1383/1550
0.33/-/0.19
0.31/-/0.17
SMF-28e+
®
LL
G.652.D
L
22
1310/1383/1550
0.34/0.34/0.22
0.32/0.32/0.18
SMF-28
®
Ultra**
ClearCurve
®
XB**
G.652.D/G.657.A1 G.652.D/G.657.A1
Z
22
1310/1383/1550
0.34/0.34/0.22
0.32/0.32/0.18
H
01
1310/1383/1550
0.4/0.4/0.3
0.35/0.35/0.20
*
Typical attenuation values match the attenuation values listed in the optical fiber specifications. See
www.corning.com/opticalfiber
for Corning optical fiber
specifications. Better attenuation performance options are available for some fiber and cable types. Contact Customer Care for additional fiber options.
*
* SMF-28
®
Ultra and ClearCurve
®
XB fiber deliver up to 10x better macrobend loss performance compared to the G.652.D standard and up to 33 percent better
macrobend loss performance than the G.657.A1 standard for 10mm radii bends.
Family Spec Sheet 0002_NAFTA_AEN
Page 4 | Revision date 2014-08-08
ALTOS
®
All-Dielectric Cables,
12-432 Fibers, Enhanced
Ordering Information |
Note: Contact Customer Care at 1-800-743-2675 for other options.
1) Cable outer diameter may change. Example: 48 F cable with 6 fibers per tube will require 8 active buffer and have an OD like a standard 96 F cable.
Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA
In reality, the dB unit is very confusing, and many experts may not be very clear about it. The following is an excerpt from the "Concise Dictionary of Measurement Unit Symbols" (by Li Shen'an) publis...
This problem of IAR has been bothering me for a long time, as shown in the following figure:This error occurred. I read the documentation today and found that the IAR routines also need to add some fi...
From being a global leader to losing the market, Korean battery manufacturers have always wanted to regain the lost market and dignity, but facing Chinese battery manufacturers represented by CAT...[Details]
"Have you set your calendar reminder?"
On August 24, Nvidia Robotics' official account posted a photo of a black gift box on a social media platform, with an attached greeting card sig...[Details]
When we travel in cities, we all find that electric vehicles have many advantages. As a means of transportation, they can also fulfill their mission well. Now, more and more residential communities...[Details]
In recent years, with the application of the IEC61850 standard and the development and deployment of optoelectronic transformers, the concept of digital substations has been put into practical use ...[Details]
White light LEDs are voltage-sensitive devices. In actual operation, their upper limit is 20mA. However, the current often increases due to various reasons during use. If no protective measures are...[Details]
The Automotive Testing and Quality Assurance Expo (ATE 2025) will open on August 27th. At the expo, Rohde & Schwarz (R&S) will showcase six automotive testing solutions, themed "Intelligently Drivi...[Details]
On August 22, the National Energy Administration released the latest data, showing that by the end of July 2025, China's total number of electric vehicle charging infrastructure will reach 16.696 m...[Details]
Permanent magnets are essential components in a wide range of household and industrial devices. They are particularly crucial in the renewable energy sector, including electric vehicle motors. Curr...[Details]
Through AI connection technology supported by Qualcomm X85 5G modem and RF and Qualcomm FastConnect 7900 mobile connection system, seamless switching can be achieved between cellular net...[Details]
Teletrac Navman has launched the Multi IQ dashcam, a cloud-based solution designed for large commercial vehicle operators. It connects up to five cameras to cover the vehicle's interior, sides, and...[Details]
Puttshack's Trackaball uses the Nordic nRF54L15 system-on-chip (SoC) to monitor sensors and enable Bluetooth low energy connectivity, while the nPM2100 power management integrated circuit (PMIC) ...[Details]
On August 20, it was reported that the specifications of Intel's upcoming Panther Lake mobile processor appeared on the Intel GFX CI website, which mainly focuses on Intel's open source Linux drive...[Details]
Driven by business opportunities such as access to new markets and government initiatives like the Belt and Road Initiative, global expansion has become a significant trend for Chinese companies. C...[Details]
The practice of warming up a car originated with gasoline-powered vehicles. Warming up the engine allows it to enter a better working state and ensures good lubrication. This has become a habit for...[Details]
Reasons for the wear of the roller press reducer shaft:
1. Since the expansion sleeve is subjected to a large torque, the mating surfaces of the shaft and the sleeve move relative to each other...[Details]