Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight
70
g
Dimensions
(L x W x H)
2.22 x 1.21 x 0.99 inches
56.48 x 30.86 x 25.10mm
MTBF
> 400 000 hrs (MIL-HDBK -217F, t=+25
o
C)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Test
Shock
Vibration
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
Conditions
Half sine wave
5gn
30 ms
before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine
1mm
3g
10-100Hz, speed 0.05Hz/s
Safety Specifications
Parameters
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Information Technology Equipment
Information Technology Equipment
EN 60950-1:2006+A11:2009
EN55011, class B
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
UL 60950-1:2007
CAN/CSA-C22.2 No.60950-1-07
Standards
Pin Out Specifications
Pin
1
2
3
4
5
AC Input (N)
AC Input (L)
+V Output
-V Output
No pin
Single
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Preliminary
Dimensions
5.27
(0.21)
56.46
(2.22)
45.72
(1.80)
Series AMEL20-AZ
20 Watt | AC-DC Converter
20.40
(0.80)
2
5,27
(0.21)
5.37
(0.21)
5
10.20
(0.40)
Top View
10.20
(0.40)
30.86
(1.21)
1
3
4
1
2
Top View
4
5
3
5.37
(0.21)
DIV: 10.00 (0.40)
25.10
(0.99)
8.00
(0.31)
5Ø 1.0 (Ø 0.04)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.05 (0.04 ± 0.002)
Pin Pitch Tolerance ±0.35 (±0.014)
1.05
(0.04)
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4.
All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for
release.
6.
This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications
which necessitate specific safety and regulatory standards other the ones listed in this datasheet.
7.
Warranty is in accordance with Aimtec’s standard Terms of Sale available