EEWORLDEEWORLDEEWORLD

Part Number

Search

LC1D80BD

Description
contactor TeSys LC1-D - 3 poles - AC-1 1000 V 125 A - coil 240 V DC
File Size82KB,3 Pages
ManufacturerETC2
Download Datasheet View All

LC1D80BD Overview

contactor TeSys LC1-D - 3 poles - AC-1 1000 V 125 A - coil 240 V DC

Product data sheet
Characteristics
LC1D80BD
contactor TeSys LC1-D - 3 poles - AC-1 1000
V 125 A - coil 240 V DC
Main
Range of product
Product or component
type
Device short name
Contactor application
Utilisation category
TeSys D
Contactor
LC1D
Motor control
Resistive load
AC-1
AC-2
AC-3
AC-4
DC
Standard
3 NO
24 V DC
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Control circuit type
Coil type
Poles description
Pole contact composi-
tion
[Uc] control circuit volt-
age
3P
Complementary
Coil technology
Protective cover
[Ie] rated operational current
Motor power kW
Built-in bidirectional peak limiting diode suppressor
With
80 A (≤ 60 °C) AC AC-3 for power circuit
125 A (≤ 60 °C) AC AC-1 for power circuit
22 kW at 220...240 V AC 50/60 Hz
37 kW at 380...400 V AC 50/60 Hz
45 kW at 415 V AC 50/60 Hz
45 kW at 440 V AC 50/60 Hz
45 kW at 660...690 V AC 50/60 Hz
45 kW at 1000 V AC 50/60 Hz
55 kW at 500 V AC 50/60 Hz
7.5 hp at 115 V AC 60 Hz for 1P motors conforming to UL
7.5 hp at 115 V AC 60 Hz for 1P motors conforming to CSA
15 hp at 230/240 V AC 60 Hz for 1P motors conforming to UL
15 hp at 230/240 V AC 60 Hz for 1P motors conforming to CSA
20 hp at 200/208 V AC 60 Hz for 3P motors conforming to CSA
20 hp at 200/208 V AC 60 Hz for 3P motors conforming to UL
25 hp at 230/240 V AC 60 Hz for 3P motors conforming to CSA
25 hp at 230/240 V AC 60 Hz for 3P motors conforming to UL
60 hp at 575/600 V AC 60 Hz for 3P motors conforming to CSA
60 hp at 575/600 V AC 60 Hz for 3P motors conforming to UL
60 hp at 460/480 V AC 60 Hz for 3P motors conforming to CSA
60 hp at 460/480 V AC 60 Hz for 3P motors conforming to UL
Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1
1 NO + 1 NC
0.1...0.3 Uc at 55 °C drop-out
0.85...1.1 Uc at 55 °C operational
75 ms
600 V for power circuit certifications UL
600 V for power circuit certifications CSA
600 V for control circuit certifications UL
600 V for control circuit certifications CSA
600 V for control circuit certifications UL
600 V for control circuit certifications CSA
690 V for control circuit conforming to IEC 60947-1
1000 V for power circuit conforming to IEC 60947-1
1000 V for power circuit conforming to IEC 60947-4-1
8 kV conforming to IEC 60947
Motor power hp
Auxiliary contacts type
Auxiliary contact composition
Control circuit voltage limits
Time constant
[Ui] rated insulation voltage
[Uimp] rated impulse withstand voltage
Wed Jul 14 09:20:37 EDT 2010
1
STM8 AD issues
I need 8 channels for multi-channel voltage sampling with STM8s103k, but the microcontroller only has 4 analog inputs. Is there any way to achieve 8-channel voltage sampling (I don't want to use an ex...
jinl3072 stm32/stm8
I would like to ask some questions and solutions about filter design! Thank you very much
[align=left][size=13px]This post is about ADI's AD8232, an analog front-end chip for ECG acquisition. Maybe many experts have not used it, but I hope everyone can come and help me take a look. In fact...
Ben讨厌苦咖啡 Microcontroller MCU
How many GPIO interrupts can the 28335 use simultaneously?
We know that the 64 pins from GPIO00 to GPIO63 in 28335 all support IO interrupts, but the interrupt sources are only XINT1~XINT7, plus XINMI, a total of 8 interrupt sources, which means that only 8 I...
DarkStar Microcontroller MCU
What’s wrong with today’s college students!!!
I have just been a moderator for a few days and I am busy with work. I can only look at everyone's questions every night. I also want to communicate with everyone and see what everyone thinks about th...
jishuaihu 51mcu
I have a very practical question!
I used 2407 platform programming before. Now I have a board made of lf2401, and I need to write programs on it. Can I use the 2407 environment? What I mean specifically is, for example, in the 2407 en...
rumeng87 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1146  687  2607  353  2285  24  14  53  8  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号