Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2636LHCB3501L380V1 Overview

Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2636LHCB3501L380V1 Parametric

Parameter NameAttribute value
Objectid312925069
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator colorYELLOW
Actuator length0.354 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
Other features380VAC FLUORESCENT LAMP
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialCOPPER
Center contact platingSILVER
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@24VDC
Contact functionON-ON
Contact resistance0.01 mΩ
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialCOPPER
End contact platingSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Jiangsu Province Electronic Design Competition Topic A
[i=s] This post was last edited by paulhyde on 2014-9-15 04:01 [/i] What do you think about the Jiangsu Province Electronic Design Competition A? Also, what is the frequency of the noise file?...
caohuajie Electronics Design Contest
PID control algorithm implementation
The algorithm of PID control is realized by explaining the principle of digital signal processing. It can be easily realized by program or FPGA....
frozenviolet Industrial Control Electronics
RP2040 components purchased from element14 event
[i=s]This post was last edited by Honghuzaitian on 2022-10-10 12:37[/i]Today I received the RP2040 purchased from the e-Network cashback event. The unboxing pictures are as follows. First is the outer...
Honghuzaitian Integrated technical exchanges
USB Power Management
USB power supply devicepower management has always been one of the main links in the design and maintenance of electronic products. In the past, if users wanted to know the power supply status, they c...
zbz0529 Power technology
Flushing steps (smart toilet development record)
Flushing requires a control switch (stepper motor) and a water pump.The above picture is the actual stepper motor and water pump control timing diagram....
weizhongc stm32/stm8
Common Faults and Solutions of Bourdon Tube Pressure Gauge
[font=微软雅黑][size=3]Common faults of spring tube pressure gauges include hairspring disorder, pressure gauge transmission mechanism wear and pressure gauge pointer not returning to zero. This post shar...
changhui01 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 607  158  165  2652  385  13  4  54  8  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号