capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment
and UPS line to battery power voltage setpoints
Built-in Emergency Power Off (EPO) interface with cable
NEMA 5-15P input plug; NEMA 5-15R output receptacles
Integrated 2-bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (bank one has 2 outlets,
bank two has 4 outlets)
Front panel LEDs offer current monitoring and battery charge level information
UPS ships fully assembled in full compliance with DOT regulations; no time-consuming connection of internal batteries by user required
Single-line tel/DSL or network Ethernet surge suppression
$250,000 Ultimate Lifetime Insurance
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
Output kVA capacity (kVA)
Output Watt Capacity (watts)
Output kW capacity
Output power factor
Crest Factor
Nominal Output Voltage(s)
Supported
Nominal Voltage details
Frequency compatibility
Frequency compatibility details
Output voltage regulation (line mode)
Output voltage regulation (Economy
line mode)
Output voltage regulation (Battery
mode)
Built-in UPS output receptacles
Built-in controllable switched load
banks
1500
1.5
1200
1.2
0.8
3:1
100V; 110V; 120V
120V default
50 / 60 Hz
Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start
+/- 2%
+/- 10%
+/- 2%
6 5-15R outlet(s)
Two switchable 5-15R load banks (bank 1 - two outlets, bank 2 - four outlets)
2/6
Output AC waveform (AC mode)
Output AC waveform (battery mode)
Sine wave
Pure Sine wave
INPUT
Rated input current (at maximum
load)
Nominal Input Voltage(s) Supported
UPS input connection type
Input circuit breaker
UPS Input cord length (ft.)
UPS Input cord length (m)
Recommended Electrical Service
Phase
12A
100V AC; 110V AC; 120V AC
5-15P
20A
10
3
15A 120V
Single-Phase
BATTERY
Full load runtime (minutes)
Half load runtime (minutes)
Expandable battery runtime
External battery pack compatibility
DC system voltage (VDC)
Battery recharge rate (included
batteries)
Replacement battery cartridge
(internal UPS battery replacement)
Battery Access
Battery replacement description
5 min. (1200w)
14 min. (600w)
Extended runtime supported via optional external battery packs
BP48V24-2U
(limit 1);
BP48V60RT-3U
(multi-pack compatible);
BP48V27-2US
(multi-pack compatible)
48
Less than 6 hours from 10% to 80%
RBC94-2U
Front panel battery access door
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description
Overvoltage correction
Undervoltage correction
Severe undervoltage correction
Online, double-conversion power conditioning
2% output voltage regulation during overvoltages to 150
2% output voltage regulation during undervoltages to 80
2% output voltage regulation during undervoltages to 65 (under 70% load only)