EEWORLDEEWORLDEEWORLD

Part Number

Search

K3HE1BAA11

Description
Rocker Switch, SPDT, On-on, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size965KB,3 Pages
ManufacturerOTTO
Websitehttp://www.ottoexcellence.com
Environmental Compliance
Download Datasheet Parametric View All

K3HE1BAA11 Overview

Rocker Switch, SPDT, On-on, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount

K3HE1BAA11 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid315810149
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator colorWHITE
Actuator length0.42 inch
Actuator materialTHERMOPLASTIC
Actuator typeROCKER
Body colorBLACK
body height35.306 mm
center contact materialBRASS
Contact (AC) maximum rated power R load0.5HP@110VAC
Contact (AC) maximum rated load I15A@125VAC
Contact (AC) maximum rated R load16A@125VAC
Maximum contact current (AC)16 A
Maximum contact current (DC)20 A
Contact (DC) maximum rated R load20A@12VDC
Contact functionON-ON
Maximum contact voltage (AC)125 V
Maximum contact voltage (DC)12 V
Dielectric withstand voltage1500VAC V
Electrical life25000 Cycle(s)
End contact materialBRASS
insulator materialTHERMOPLASTIC
Manufacturer's serial numberK3
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
surface mountNO
switch functionSPDT
Switch typeROCKER SWITCH
Terminal length0.39 inch
Terminal materialBRASS
Termination typeQUICK CONNECT
SEALED, ILLUMINATED ROCKER SWITCHES
ATTRACTIVE & RUGGED FOR WET & DUSTY ENVIRONMENTS
SEALED
ROCKERS
K3
The OTTO K3 rocker switch is a quality, precision switch designed
to comply with standards established for appliance, marine (ignition
protection) and off-road vehicles along with other demanding
applications where rugged rocker switches are required.
K3 sealed rocker switches snap into industry-standard panel
cutouts. Choose illuminated and printed legends, thru-panel
drain option and switching compatibility from low level to
20 amps.
The K3 offers a choice of LED, incandescent and neon
illumination. Legends can be stamped onto a non-illuminated
button, stamped onto an illuminated lens or laser etched into
the lens and backlit.
Available in standard and low level contact ratings, the K3
rockers will fit a wide range of applications. Expect a minimum
of 25,000 cycles at a full rated load of 20 amps resistive or 15
amps inductive. 100,000 cycles mechanical. A full complement
of switch operation is available including momentary and
maintained action in 2 or 3-position switches in SPST, SPDT,
SPTT, DPST and DPDT circuit arrangements.
OTTO can provide custom colors upon request. Value-added
assemblies with wire leads are also available. Please consult the
factory for assistance.
Standard Characteristics/Ratings:
ELECTRICAL RATINGS:
Load
Resistive
Inductive
Lamp
Motor
DWV
Low Level
Electrical Life:
25,000 cycles
Sea Level
@ 12/28VDC
20A
15A
5A
0.5HP @ 110VAC
1050Vrms except across light terminals
10mA @ 30mV
Sea Level
@ 125VAC, 60Hz
16A
15A
5A
ROCKER SWITCHES
Features:
• Sealed watertight per IP68S
• Snap-in panel mounting into industry standard
panel cutout
• Optional panel seal gasket
• Thru-panel drain option
• LED, neon & incandescent lighting
• 0.250” Quick Connect terminals
• Optional one-piece connector
• Optional terminal barriers
• Low level up to 20 amp switch
• Configurable Single Pole Triple Throw (SPTT)
with external jumpers
• RoHS/WEEE/Reach compliant
LIGHTING:
Light Source
Incandescent
Neon
LED
Mechanical Life:
Seal:
Rating
(VDC) 6V, 12V, 24V
(VAC) 125V, 250V
(VDC) 2V, 6V, 12V, 24V
100,000 cycles
IP68S
Operating Temp Range:
-40°C to +85°C
MATERIALS:
Case:
Button:
Terminals/Contact:
Terminal Hardware:
Thermoplastic, black
Thermoplastic
Brass, silver alloy with silver plate, gold flash for low level
K3 series recommended Quick Connect terminals:
AMP 60253-2 for 12-16 AWG
AMP 42100-2 for 14-18 AWG
None provided
Mounting Hardware:
Specifications Subject To Change Without Notice
www.ottoexcellence.com
153
ADS, error bad symbol problem, newbie asks for help from experts
Hello everyone, please help me solve the problem. What is the reason for the bad symbol error in memcfg.s? I downloaded a complete program from the Internet. It can be compiled without adding the INC ...
longbiao831 ARM Technology
I am about to start writing my thesis, but I still have no idea where to start. Could you guys give me some pointers?
I will start my project at the end of the month, but I have no idea what to do. I want to work on embedded systems. Could you please give me some advice? 1) It should have some practical significance;...
zhuohuatree Embedded System
Is there any special value in the C2000 series DSP?
Is there any special value in the C2000 series DSP? It is expensive, consumes a lot of power, and is difficult to get started. I don't see any special features....
milan111 Microcontroller MCU
ActiveDeviceEx() dynamic driver loading problem
ActiveDeviceEx() dynamically loads the driver, which requires me to add the driver configuration item in the registry HKEY_LOCAL_MACHINE\Drivers\Builtin\ before calling the function. In order to avoid...
wujun0713 Embedded System
Analysis of 2020 E-sports Contest C: The realization process of the 99-point ramp car
[i=s]This post was last edited by qwqwqw2088 on 2020-10-30 08:59[/i]Training during the day and staying up late to do exercises, they scored 99 points (out of a total of 120 points) in the TI Cup. The...
qwqwqw2088 Electronics Design Contest
MSP430F4152 development board schematic diagram
...
fish001 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2294  1401  801  1611  2913  47  29  17  33  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号