TA35-C183H200C0-CZM23

Description
Thermal Circuit Breaker, 2 Pole(s), 20A, 240VAC, 60VDC, Panel Mount,
CategoryCircuit protection    Circuit protection   
File Size3MB,8 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

TA35-C183H200C0-CZM23 Overview

Thermal Circuit Breaker, 2 Pole(s), 20A, 240VAC, 60VDC, Panel Mount,

TA35-C183H200C0-CZM23 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerSCHURTER
Reach Compliance Codecompli
Actuator typeROCKER
body width26 mm
body height43.9 mm
Body length or diameter39 mm
circuit functionTRIP FREE
Circuit protection typeTHERMAL CIRCUIT BREAKER
Environmental characteristicsIP40; IP00
Installation featuresPANEL MOUNT
Number of poles2
Maximum operating temperature60 °C
Minimum operating temperature-30 °C
physical size39mm x 26mm x 43.9mm
Rated current20 A
Rated voltage (AC)240 V
Rated voltage (DC)60 V
GuidelineCSA; CUL; IEC; UL; VDE
surface mountNO
Terminal shapeQUICK CONNECT
Base Number Matches1
circuit breakers
Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole
TA35 1-pole
TA35 2-pole with CZM23 cover
TA35 3-pole
(pending)
Description
Thermal circuit breaker 1-, 2- or 3-pole
Supplementary protector for general industrial use
Positively trip-free release
Snap-in mounting
Version with illuminated rocker
Different rocker colours
Protection cover for IP65
«Dead-Man»-version (Momentary switch)
Applications
Power tools
Industrial equipment
Equipment for building construction
Medical equipment
Cleaning equipment
Power generators
Commercial and household kitchen appliances
Standards
– IEC 60934
– UL 1077
– CSA C22.2 235
– GB 17701 (pending)
Weblinks
Approvals: http://www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
TeChniCAl DATA
Rated voltage U
e
1-pole
2-pole
3-pole
Rated current I
n
1- / 2-pole
3-pole
1- / 2-pole, AC 240 V
3-pole, AC 415 V
Accessible range
Terminal side
50 Hz
Impulse 1.2/50 µs
DC 500 V
AC 240 V / 50/60 Hz
DC 32 V
AC 240 V / 50/60 Hz
DC 60 V
AC 415 Y/240 V / 50/60 Hz
0.05 – 20 A
0.05 – 12 A
0.05…20 A: 2000 A, SC (C1)
0.05…12 A: 2000 A
Shock resistance
Degree of protection
IP 40
IP 00
> 2500 V
> 4000 V
> 100 MOhm
Max. switching capacity 1-, 2-pole
for switch only types
3-pole
(without bimetal)
20 A
12 A
Type of tripping
Weight
1-pole
2-pole
3-pole
Overload
IEC 60934
UL 1077
min. 40 cycles @ 6 x I
n
,
cos phi 0.6
min. 50 cycles @ 1.5 x I
n
,
cos phi 0.75 (OLØ)
–30 °C to +60 °C
Admissible ambient
air temperature
Resistance to vibration
IEC 60068-2-6, Test Tc
Conditional short
circuit I
nc
10…60 Hz: ±0.75 mm
60…500 Hz: 10 G
IEC 60068-2-27, Test Ea 30 G / 18 ms
Thermal positively trip free
19 g
32 g
45 g
Dielectric strength
Insulation resistance
Endurance (typical)
Mechanical
50’000 cycles
AC: 1 x I
n
, cos phi 0.6
50’000 cycles
DC: 1 x I
n
, L/R = 2…3ms 50’000 cycles
2
circuit breakers
Six methods to check short circuit of PCB circuit board
[align=left] [/align][align=left]1. Open the PCB design on the computer, light up the short-circuited network, and see where it is closest and easiest to connect. Pay special attention to the short ci...
szjlczhang PCB Design
Program crashes
Please help, please help me, please help me :Cry: Briefly explain the problem: I made a version of CPLD program, the initial version is referred to as A, the function is normal, and there is no proble...
pouty7447 FPGA/CPLD
Life is short, you must be sexy~
Everything is just floating clouds ... floating clouds ...Ah! School is over!!!I have a nice butt~~~HI~ Am I pretty ~Eh? Don’t you recognize me?Squirrel: Seriously, can you give me the pine cone on yo...
心仪 Talking
Please help PROTEL experts
I used PROTEL to draw a PCB. When I transferred the schematic to the PCB, I found that all the components of the PCB were piled together. Can you tell me what's going on? Is there a good way to quickl...
haojun88 Analog electronics
ARM Microcontroller Quick Start
ARM Microcontroller Quick Start...
zuie ARM Technology
[Solved] 0 is recognized as NULL. How to solve it?
[i=s]This post was last edited by Tobey on 2016-10-16 17:27[/i] In order to save memory usage, the parameters of multiple calling functions are pointer addresses, and a null pointer check is added. As...
Tobey Programming Basics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1846  705  2472  822  257  38  15  50  17  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号