EEWORLDEEWORLDEEWORLD

Part Number

Search

LP219417

Description
30 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK
CategoryThe connector   
File Size2MB,6 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

LP219417 Overview

30 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK

LP219417 Parametric

Parameter NameAttribute value
Objectid1871352516
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresSAFETY APPROVAL: UL 94V-0, THERMOPLASTIC
Fastening methodSCREW
Manufacturer's serial numberLP2
Installation typeBOARD
Number of layers1
Rows1
Number of channels17
Rated current30 A
Rated voltage150 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
MAGNUM
®
Series A2000, LP2000 & CB2000
Single Row Terminal Blocks
Single & Double Row
Filtered Connectors
A20510807WR
Euro-MAG Series
PCB – Spring Clamp
SPECIFICATIONS
Rating:
A2: 30A, 300V*
LP2: 30A, 150V*
CB2: 30A, 300V*
Center Spacing:
.375” or 3/8” (9.52 mm)
LP202110
Wire Range:
#12-22 AWG CU
Screw Size:
#6-32 zinc plated philslot
Torque Rating:
9 in-lb.
Base:
Standoffs standard for easy flux washing
Distance Between Barriers:
.32” (8.1 mm)
Recommended PCB Hole Diameter:
.076” (1.93 mm)
Operating Temperature
: 105°C (221°F) max., -40°C (-40°F) min.
Molded Material:
Black, UL Rated 94V0 Thermoplastic
Breakdown Voltage:
3400V (A2 & LP2); 4100V (CB2).
Agency Information:
UL/CSA; IEC Compliance;
CE Certified
*30A Rating achieved with a #10 copper wire crimped to a ring terminal.;
20A Rating without ring terminal.
CB20210507
A2000 & LP2000 Series
.375
(9.53)
.15
(3.8)
dia.
.65
(16.5)
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
MOUNTING
ENDS
ONLY
A
C
Mount Ctrs.
Length
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
1.56
1.93
2.30
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.69
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.56
10.93
11.31
11.68
12.05
BARRIER &
MOUNTING
ENDS
B
Pole Ctrs.
.38
.75
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
BARRIER
ENDS
ONLY
C
Length
.81
1.18
1.56
1.93
2.31
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.68
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.55
10.93
11.31
11.68
12.05
C
Mount End
Barrier End
Base & Rail Mount
Connectors
.76 (19.3)
.40
(10.2)
.565 (14.35)
on LP2000
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
CB2000 Series
.19
(4.8)
dia.
Power Distribution Blocks
.375
(9.53)
.70
(17.8)
.32
(8.1)
Mount End
C
Barrier End
.60
(15.2)
WIRE MANAGEMENT PRODUCTS
* Dimensions in inches. To convert to millimeters, multiply by 25.4.
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
6
In which directory is tux.exe in cetk stored?
I just came into contact with cetk, which mentioned the use of tux.exe, but I have searched for a long time and couldn't find it. May I ask you, in which directory is tux.exe in cetk stored? I hope yo...
panyinggaotian Embedded System
Latest STM32F0308-DISCOVERY development tool related information
[url=http://www.st.com/st-web-ui/static/active/en/resource/technical/document/data_brief/DM00092305.pdf]STM32 F0308 Development Board Data Summary[/url] [b][color=#0000ff]Technical Documentation:[/col...
EEWORLD社区 stm32/stm8
Inductor... Inductor... Why do you keep yelling~~
When I was working on switching power supplies, I encountered an inductor with a current greater than 1A.Regarding the howling problem, I asked others and they said it was because the inductor power w...
Coding_阿狸 Power technology
Please advise on the use of transformers in circuits!
What kind of transformer should I use to amplify a 12V 40KHZ square wave signal to about 40V? I used a small transformer with two pins on one side and three pins on the other side! But when a square w...
zl364908957 Analog electronics
Homemade simple JTAG download and programming tool
This article is excerpted from the book "A Practical Guide to Linux Kernel Development for Embedded Systems (ARM Platform)". In my second year of work (1997), I designed and produced a modular chiller...
xb123 Embedded System
Some suggestions for dealing with serpentine lines
1. Try to increase the distance (S) between parallel segments, at least greater than 3H, where H refers to the distance from the signal routing to the reference plane. In layman's terms, routing is do...
clj2004000 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2041  1115  2608  1623  1670  42  23  53  33  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号