PBB10C Series
6 0 0 - 1 0 0 0 W AT T S -
FEATURES
•
•
•
•
•
•
•
High power & peak power
10 seconds peak current, 35% duty cycle.
Natural convection cooling
Increased power with forced air cooling
Parallel, master-slave, and N+1 redundant
operation
Harmonic attenuator IEC 61000-3-2
Universal input (85-264Vac)
AC/DC SINGLE OUTPUT
OPEN FRAME & ENCLOSED
SPECIFICATIONS
INPUT
ENVIRONMENTAL
Voltage
Frequency
Inrush current
Efficiency
Isolation
85-264Vac or 120-350Vdc
50/60Hz (47-63Hz) or DC.
40A typical.
84%-89% typical
In/Out 3kVac, 1min / R>50MΟηµ @ 500Vdc
In/Gnd 2kVac, 1min / R>50MΟηµ @ 500Vdc
Out/Gnd 500Vac, 1min / R>750MΟηµ @ 500Vdc
See table
±10% of rated voltage.
See table.
150mVp-p – 250mVp-p max.
96mV – 192mV max.
150mV – 300mV max.
Various, between 130% - 170% of rated voltage
Over 101% of peak current
500ms max.
20ms typical
10 sec, 35% duty cycle
Operating temperature
Humidity
Vibration
Impact
STANDARDS
-10°C to 70°C (Refer to derating curve, consult
Powerbox sales).
20 – 90% RH Non-Condensing
10Hz-55Hz 19.6m/s
2
(2G) 3 mins x, y and z
axes
196.1m/s2 (20G), once along x, y and z axes
OUTPUT
Safety standards
Voltage
Voltage adjustment
Output current
Ripple & noise
Line regulation
Load regulation
Over voltage protection
Over current protection
Startup time
Holdup time
Peak load
EN60950-1, EN50178, UL60950-1 and C-UL
Complies with DEN-AN and IEC60950-1
(AC input only)
AS/NZS CISPR11 Group 1 Class A.
EN61204-3, EN61000-6-2, EN61000-3-2,
EN61000-4-2,-3,-4,-5,-6,-8,-11
FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with LVD and EMC Directives
C-Tick
EMC standards
EMI standards
CE marking
Doc. No. PBC9 Rev.C 28-4-11
Powering Progress – www.powerbox.com.au
49