EEWORLDEEWORLDEEWORLD

Part Number

Search

TPHBU31-104

Description
Medical Power Supplies For Health Care Applications
File Size281KB,2 Pages
ManufacturerTotal Power International
Websitehttp://www.total-power.com/
Download Datasheet Compare View All

TPHBU31-104 Overview

Medical Power Supplies For Health Care Applications

Total
Tota Power International, Inc.
TPHBU31 SERIES
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
Internal EMI filter
Single Output
Over Voltage and Over Load protection
Size: 1.5"x4"x0.83"
Class II
2 year warranty
30W Open Frame Type
Medical Power Supplies For Health Care Applications
Electrical Characteristics:
Vin
fin
Po
Vo
Io
Iil
Iih
Ir
Eff
REG-i
OCP
Ttr
Th
Ts
Vp-p
TC
OA
Pno
Vps
Safety Approvals Input Voltage Range
Operate Voltage Range
Input Frequency
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Line Regulation
Io=Full load, Vin=100VAC
Io=Full load, Vin=240VAC
Io=Full load, 25°C, Cool start, Vin=115VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
Vin=230VAC
100~240VAC
90~264VAC
47~63Hz
See rating chart
See rating chart
See rating chart
0.8A
0.4A
25A (max.)
50A (max.)
72~89%
1% (max.)
5% (max.)
110~150%
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
All output
4mS (max.)
12mS (min.)
0.3~2S
1% (max.)
±0.04%/°C
Up to 3000m
No load, Vin=230VAC
Primary to secondary
See rating chart
5888VDC (min.)
EN 60601-1
IEC 60601-1
Application:
- Blood Pressure system
- Portable medical devices
- ECG machine
Safety Approvals:
RoHS
2002/95/EC
COMPLIANT
REG-o Load Regulation
Over Current Protection
Time of Transient Response
Hold-Up Time
Start Up Time
Ripple & Noise(Peak to Peak)
Temperature Coefficient
Operating Altitude
No-Load Power Consumption
Dielectric Withstanding Voltage
Environmental
To
Ts
Ho
Hr
MTBF
Pd
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Operating Temperature at 25°C
,
Calculated per MIL-HDBK-217F
Derate linearly from 100% load at 40°C to 50% load at 70°C
See derating curve
-40~85°C
0~95%
0~95%
0.1M Hrs (min.)
Total Power In
International, Inc
Toll Free: 877-646-0900
www.total-power.com

TPHBU31-104 Related Products

TPHBU31-104 TPHBU31 TPHBU31-102 TPHBU31-103 TPHBU31-105 TPHBU31-106 TPHBU31-107 TPHBU31-108 TPHBU31-109 TPHBU31-110
Description Medical Power Supplies For Health Care Applications Medical Power Supplies For Health Care Applications Medical Power Supplies For Health Care Applications Medical Power Supplies For Health Care Applications Medical Power Supplies For Health Care Applications Medical Power Supplies For Health Care Applications Medical Power Supplies For Health Care Applications Medical Power Supplies For Health Care Applications Medical Power Supplies For Health Care Applications Medical Power Supplies For Health Care Applications

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2118  2881  1989  2113  2590  43  59  41  53  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号