EEWORLDEEWORLDEEWORLD

Part Number

Search

MPV1060S-24RHI

Description
Compact, 6:1 Input PV Power 5 & 10W DC/DC Converters
File Size775KB,4 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet Compare View All

MPV1060S-24RHI Overview

Compact, 6:1 Input PV Power 5 & 10W DC/DC Converters

MPV10RHI
Series
Compact, 6:1 Input
PV Power 5 & 10W
DC/DC Converters
Electrical Specifications
Key Features:
5W & 10W Output Power
200 - 1200 VDC Input Range
4,000 VDC Isolation
Input Under Volt Protection
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Start Voltage
Under Voltage Shutdown
Conditions
Min.
200
185
175
Typ.
600
MPV05
Output Over Volt Protection
Input Current
Compact Case
-25°C to +70°C Operation
>300 kHours MTBF
Inrush Current
Start-Up Time
MPV10
200 VDC Input
600 VDC Input
1200 VDC Input
200 VDC Input
600 VDC Input
1200 VDC Input
200 VDC Input
600 VDC Input
1200 VDC Input
Max.
1,200
195
185
36.0
13.0
8.0
69.0
24.0
14.0
Units
VDC
VDC
VDC
mA
4.0
12.0
25.0
500
A
mS
Units
%
%
%
mV P - P
%/°C
%I
OUT
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Temperature Coefficient
Over Power Protection
Output Short Circuit
Conditions
Typ.
±1.0
V
IN
= M
IN
to M
AX
±0.5
±0.5
I
OUT
= 5% to 100%
See Note 1
50
±0.02
Autorecovery
110
Continuous (Autorecovery)
Min.
4,000
100
Typ.
Min.
Max.
±2.0
±1.0
±1.0
100
General
Parameter
Isolation Voltage
Isolation Resistance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFM
Voltage Dips
Conditions
60 Seconds
500 VDC
Max.
Units
VDC
M
kHz
65
Standard
See Note 2
EN 55022
See Note 2
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 3
EN 61000-4-4
See Note 4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Conditions
Min.
Typ.
Max.
Units
Class A
Class A
Criteria B; ±6 kV/±8
Criteria A; 10V/m
Criteria B; ±4 kV
Criteria B; ±1 kV /±2 kV
Criteria A; 10 Vrms
Criteria A; 10A/m
Criteria B; 0% - 70%
Max.
+70
+105
95
Units
°C
°C
%
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Min.
Typ.
-25
+25
-25
Free Air Convection
RH, Non-condensing
Ambient
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
See Mechanical Drawings (Page 4)
Aluminum Alloy With Non-Conductive Base (UL94-V0)
6.92 Oz (195g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
Wave Soldering
Manual Soldering
Min.
300
Min.
255
350
Typ.
Max.
Units
kHours
Units
°C
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Lead Temperature, See Note 5
Typ.
260
360
Max.
265
370
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com

MPV1060S-24RHI Related Products

MPV1060S-24RHI MPV0560S-05RHI MPV1060S-05RHI MPV10RHI
Description Compact, 6:1 Input PV Power 5 & 10W DC/DC Converters Compact, 6:1 Input PV Power 5 & 10W DC/DC Converters Compact, 6:1 Input PV Power 5 & 10W DC/DC Converters Compact, 6:1 Input PV Power 5 & 10W DC/DC Converters
####How to define and send several consecutive hexadecimal numbers? ? ? ##
I want to send out a string of hexadecimal numbers, which are: 0x7E 0x01 0x01 0x00 0x01 0x01 0x04 0x0D[/size] [size=4]So I put them in an array like this:[/size] [size=4]char DO_leici_START[8]={0x7E,0...
面纱如雾 MCU
DSP high-speed ADC system based on FIFO and level converter
[i=s] This post was last edited by paulhyde on 2014-9-15 03:40 [/i] This paper presents a design of a high-speed data acquisition system using the DSP digital signal processing chip TMS320VC5402 as a ...
txiuchao Electronics Design Contest
Could you please tell me how to simulate various anomalies of MPC860 through software?
The exceptions of MPC860 are as follows (their exception vector offset addresses are in brackets): system reset (0x0100), machine check exception (0x0200), DSI data storage exception (0x0300), ISI ins...
dcqqok Embedded System
GreenChip leads industry innovation
The era of smart lighting has arrived, and GreenChip is leading the industry innovation! NXP provides you with a complete GreenChip smart lighting solution. Its lighting product portfolio can provide ...
恩智浦半导体 Integrated technical exchanges
Let's be proud of it. The new product is online for trial.
In the charging workshop of the battery factory, the old-fashioned meter head was replaced with a digital tube and an abnormal current alarm function was added....
吴下阿蒙 MCU
Where is the TCP/IP protocol stack code inside wince?
Or is there any simple TCP/IP protocol stack that can be ported to wince?...
XWXWANG Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2044  1055  1972  357  2273  42  22  40  8  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号