Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Start Voltage
Under Voltage Shutdown
Conditions
Min.
200
185
175
Typ.
600
MPV05
•
Output Over Volt Protection
Input Current
•
Compact Case
•
-25°C to +70°C Operation
•
>300 kHours MTBF
Inrush Current
Start-Up Time
MPV10
200 VDC Input
600 VDC Input
1200 VDC Input
200 VDC Input
600 VDC Input
1200 VDC Input
200 VDC Input
600 VDC Input
1200 VDC Input
Max.
1,200
195
185
36.0
13.0
8.0
69.0
24.0
14.0
Units
VDC
VDC
VDC
mA
4.0
12.0
25.0
500
A
mS
Units
%
%
%
mV P - P
%/°C
%I
OUT
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Temperature Coefficient
Over Power Protection
Output Short Circuit
Conditions
Typ.
±1.0
V
IN
= M
IN
to M
AX
±0.5
±0.5
I
OUT
= 5% to 100%
See Note 1
50
±0.02
Autorecovery
110
Continuous (Autorecovery)
Min.
4,000
100
Typ.
Min.
Max.
±2.0
±1.0
±1.0
100
General
Parameter
Isolation Voltage
Isolation Resistance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFM
Voltage Dips
Conditions
60 Seconds
500 VDC
Max.
Units
VDC
M
kHz
65
Standard
See Note 2
EN 55022
See Note 2
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 3
EN 61000-4-4
See Note 4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Conditions
Min.
Typ.
Max.
Units
Class A
Class A
Criteria B; ±6 kV/±8
Criteria A; 10V/m
Criteria B; ±4 kV
Criteria B; ±1 kV /±2 kV
Criteria A; 10 Vrms
Criteria A; 10A/m
Criteria B; 0% - 70%
Max.
+70
+105
95
Units
°C
°C
%
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Min.
Typ.
-25
+25
-25
Free Air Convection
RH, Non-condensing
Ambient
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
See Mechanical Drawings (Page 4)
Aluminum Alloy With Non-Conductive Base (UL94-V0)
6.92 Oz (195g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
Wave Soldering
Manual Soldering
Min.
300
Min.
255
350
Typ.
Max.
Units
kHours
Units
°C
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Lead Temperature, See Note 5
Typ.
260
360
Max.
265
370
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MPV0560S-05RHI
MPV1060S-05RHI
MPV1060S-24RHI
Voltage
(VDC)
Nominal
600
600
600
Range
200 - 1200
200 - 1200
200 - 1200
Voltage
(VDC)
www.micropowerdirect.com
Output
Efficiency
Current
(mA, Max)
Current
(mA, Min
)
(%, Typ)
Over
Fuse
Voltage Capacitive
Rating
Load
Protection
(µF, Max)
Slow-Blow
(VDC Typ)
(mA)
5.0
5.0
24.0
1,000
2,000
420
0.0
0.0
0.0
73
75
82
7.5
7.5
29.0
10,000
6,000
1,500
1,000
1,000
1,000
Notes:
1. To meet the specified ripple and noise levels, external capacitors are required. see the typical connection information on page three for recommended values. For more information, please
contact the factory.
2. All units will meet EN 55022 (CE/RE) class A with the input circuit shown in the “Typical Connection 2” diagram on page 3. Contact the factory for more information.
3. All units will meet EN 61000-4-4 (±4 kV) with the input circuit shown in the “Typical Connection 2” diagram on page 3. Contact the factory for more information.
4. All units will meet the requirements of EN 61000-4-5 (±1 kV/±2 kV), with the input circuit shown in the “Typical Connection 2” diagram on page 3. Contact the factory for more information.
5. Lead temperature is measured 1.5 mm from the case.
6. Operation at no load will not damage the units, however, they may not meet all specifications.
7. It is recommended that a fuse be used on the input of a power supply for protection. For the
MPV0560-xxRHI
&
MPV1060-xxRHI
series, a 1.0A slow blow should be used.
Derating Curve,
MPV1060S-05
Derating Curve,
MPV0560S-05 & MPV1060S-24
Efficiency vs Input Voltage
(Full Load)
Efficiency vs Output Power
(V
IN
= 600 VDC)
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
Typical Connection 1
www.micropowerdirect.com
The diagram at left illustrates a typical connection of the
MPV0560S-xxRHI
or
MPV1060S-xxRHI
series. Output
capacitors C
6
and C
5
are filtering components. They
are required to meet ripple and noise specifications.
The recommended input components are a fuse, NTC,
and MOV. The recommended component values for
these are given in the table below.
Typical Connection 2
: With External EMC Components
For applications that require meeting higher EMC standards, the circuit shown above is recommended. Some notes
on this diagram (starting with the input circuit) are:
1. It is recommended that an external fuse be used. The recommended fuse is 1A/250V.
2. The NTC helps to prevent damage to the module in case an input current surge occurs. The recommended value
is given in the table below.
3. The MOV helps to prevent damage to the module in case an input voltage surge occurs. The recommended value
is given in the table below.
4. Capacitors C
1
, C
2
, C
3
and C
4
are input filter components (connected in series to achieve the required capacitance
level). Resistors R
1
, R
2
, R
3
and R
4
help to balance the current across the capacitors.
5. Recommended values for components are:
6. Capacitor C
5
is ceramic. This capacitor is used to filter high frequency noise. A recommended value is
given in the table below.
7. Capacitor C
6
is an electrolytic. A low ESR, high frequency capacitor should be used. The recommended
value is given in the table below.
8. The output TVS will help protect system circuitry if power supply fails. A recommended value is given in
the table below.
9. Derating on all capacitors should be 80% or more.
Model
Number
MPV0560S-05RHI
MPV1060S-05RHI
MPV1060S-24RHI
External Components
NTC
MOV
C
1
, C
2
, C
3
, C
4
R
1
, R
2
, R
3
, R
4
C
5
C
6
220
μF/25V
120
μF/35V
TVS
SMBJ7.0A
SMBJ30A
5D-9
SK201000
47
μF/450V
1 M /2W
1.0
μF/50V
Typical Board Layout
: With External EMC Components
This diagram illustrates a typical board
layout for the
MPV0560S-xxRHI
or
MPV1060S-xxRHI
with the recom-
mended EMI components shown in
the “Typical Connection 2” diagram. To
meet safety regulations, the board trace
widths should be >3 mm, the distance
between traces should be >6 mm,
and the distance between traces and
ground should be >6 mm. Contact the
factory for more information.
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
Mechanical Dimensions
www.micropowerdirect.com
Pin Connections
Pin
1
2
3
4
5
6
Function
+V
IN
-V
IN
No Connection
No Connection
-V
OUT
+V
OUT
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx = ±0.02 (±0.50)
More Ultra-Wide Input DC/DC Products
MicroPower Direct
offers a two more DC/DC product families with specifications that are ideal for use in photovoltaic
applications. The
MPV1560S
and
MPV4060S
offer a unique combination of compact size, very wide input range,
very high isolation and low cost. Features Include:
•
15W & 40W Output Power
•
200 - 1200 VDC Input Range
•
4,000 VDC Isolation
•
Under Input Volt Protection
•
Over Output Volt Protection
•
Short Circuit Protection
•
High Efficiency
•
Compact Packaging
•
-25°C to +70°C Operation
•
High MTBF
MicroPower Direct
also offers DC/DC product families with specifications
that are ideal for use in railway/transportation applications. Call us today or