EEWORLDEEWORLDEEWORLD

Part Number

Search

M57400201001U070BS

Description
Pressure Sensor
CategoryThe sensor   
File Size624KB,6 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

M57400201001U070BS Overview

Pressure Sensor

M57400201001U070BS Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145037757943
Reach Compliance Codeunknown
Maximum accuracy(%)0.25%
Other featuresSENSOR SEATED HEIGHT ALONG WITH PORT 84.2 MM
body height70.26 mm
Body length or diameter23.97 mm
shellSTAINLESS STEEL
Installation featuresPANEL MOUNT
Maximum working current5 mA
Maximum operating temperature60 °C
Minimum operating temperature-10 °C
Output range1-5V
Output typeVOLTAGE OUTPUT
Package Shape/FormCYLINDRICAL
port typeG1/4DIN3852
Maximum pressure range1015.26 Psi
Minimum pressure range
Pressure sensing modeSEALED
Response time2000 µs
Sensor/temperature sensor typePRESSURE SENSOR,PIEZORESISTIVE
Maximum supply voltage30 V
Minimum supply voltage8 V
surface mountNO
Termination typeCABLE
MEAS 5700
Subermsible Liquid Level Pressure Transducer
SPECIFICATIONS
CE Compliant and Waterproof
Variety of Pressure Port Configurations
Optional Stainless Steel Snubber
IP68 Rated Connection and Submersible Polyurethane
Jacketed Cable
Gage, Sealed, Compound
Low Cost
Features
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.25% Accuracy
Up to ±1% Total Error Band
Compact Outline
IP68 Waterproof Grade
Custom Cable Lengths
Polyoxymethylene Protective Cap for Liquid Level
Applications
The M5700 submersible
pressure transducer from the Microfused line of
MEAS, with its modular design, includes an IP68 rated connection and
submersible polyurethane jacketed cable along with a variety of pressure
port options. This series features a low-cost solution for applications
requiring a pressure transducer for use in wet or submerged
environments. This series is suitable for measurement of liquid or gas
pressure, even for difficult media such as contaminated water, steam, and
mildly corrosive fluids.
The transducer’s durability is excellent with no O-rings or organics
exposed to the pressure media. The transducer can be fully submerged
since the wetted materials for the back end consist of FKM
Fluoroelastomers,
316L or 17-4PH stainless steel and polyurethane. A
polyoxymethylene protective cap port option is also available for liquid
level applications. The M5700 is weatherproof and exceeds the latest
heavy industrial CE requirements including surge protection. The circuit
is protected from reverse wiring at input and short circuit at output.
This product is geared to the OEM customer for low to high volumes. TE
stands ready to provide a custom design of the M5700 where the volume
and application warrants. Additional configurations not listed are either
available or possible. Please inquire for further information.
Applications
Tank Pressure and Level
Cryogenic Tanks
Pump and Compressor Controls
Marine and Water Systems
Agricultural Sprayers (Water, Fertilizer, Pesticide)
Fire Suppression Systems
Liquid Level Applications
Refrigeration Systems (Chillers)
Tractors (Hydraulic)
Outdoor Pressure Applications
TE CONNECTIVITY SENSORS
/// M5700
04/2018
Page 1
Problems in STM32 initialization
[table=98%][tr][td]From EEWORLD cooperation group: arm linux fpga embedded 0 (49900581) Group owner: wangkj [/td][/tr][/table]...
IC-钱龙 stm32/stm8
Project_zero of cc2640r2f adds pwm output to peripheral circuit to drive small motor
Project_zero of cc2640r2f adds pwm output to the peripheral circuit to drive the small motor function: cc2640r2f outputs 4 controllable PWM, 2 signals can drive a small motor forward and reverse signa...
蓝雨夜 Wireless Connectivity
Common electronic components testing methods and experience
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:57[/i]Common electronic component detection methods and experience (Part 1) Component detection is a basic skill for home appliance mai...
探路者 Mobile and portable
How to deal with a single signal line crossing a clock domain?
[i=s]This post was last edited by Bai Ding on 2016-2-7 17:42[/i] Reposted from [url=http://www.21ic.com/mcucourse/201601/661616.htm]http://www.21ic.com/mcucourse/201601/661616.htm[/url] Over the past ...
白丁 FPGA/CPLD
DM648 self-starting problem caused by CMD file under CCS5.2
I used to use CCS3.3, because the software was too prone to blue screens and crashes, and using a virtual machine seriously affected the speed of the emulator. So I switched to CCS5.2.The ECLIPS archi...
灞波儿奔 Microcontroller MCU
A small question about the 15-year-old wind pendulum
Where should the mpu6050 be placed? What are the differences between the results measured in different places? The purpose of solving the above problems is to obtain a more accurate pendulum deflectio...
Jorring Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1102  2337  1401  337  1642  23  48  29  7  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号