Operating Temperature Range .........................-40°C to +125°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow) .......................................+260°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(V
CC
= full range, T
A
= -40°C to +125°C, unless otherwise specified. Typical values are at T
A
= +25°C.) (Note 1)
PARAMETER
Operating Voltage Range
SYMBOL
V
CC
V
CC
= 5.5V, no load
V
CC
Supply Current
I
CC
V
CC
= 3.6V, no load
V
CC
= 2.5V, no load
V
CC
= 1.8V, no load
V
CC
Reset Threshold
(See Reset Thresholds table)
Reset Threshold Tempco
V
CC
to Reset Delay
T
A
= +25°C
V
TH
T
A
= -40°C to +125°C
∆V
TH
/°C
V
CC
falling at 10mV/µs from V
TH
+ 100mV
to V
TH
- 100mV
D1
D2
Reset Timeout Period
MAX6381–MAX6389
(See Reset Timeout table)
D3
t
RP
D5
D6
D4
D7
MR
timeout period
Reset Timeout Period
MAX6390
t
RP
V
CC
timeout period
V
IL
V
TH
< 4V
MR
Input Voltage
V
IH
V
IL
V
IH
V
TH
> 4V
0.7 x
V
CC
0.8
2.4
D4
D7
D4
D7
1
20
140
280
560
1120
1200
140
150
1120
1200
V
TH
-
1.5%
V
TH
-
2.5%
CONDITIONS
MIN
1.0
7
6
4
3
V
TH
V
TH
60
35
2
40
280
560
1120
2240
2400
280
300
2240
2400
0.3 x
V
CC
V
ms
ms
TYP
MAX
5.5
13
11
7
6
V
TH
+
1.5%
V
V
TH
+
2.5%
ppm/°C
µs
µA
UNITS
V
2
SC70/µDFN, Single/Dual Low-Voltage,
Low-Power µP Reset Circuits
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= full range, T
A
= -40°C to +125°C, unless otherwise specified. Typical values are at T
A
= +25°C.) (Note 1)
PARAMETER
MR
Minimum Input Pulse Width
MR
Glitch Rejection
MR
to Reset Delay
MR
Internal Pullup Resistance
MAX6381–MAX6389
MAX6390
T
A
= +25°C
RESET IN Input Threshold
V
THRST
T
A
= 0°C to +85°C
T
A
= -40°C to +125°C
RESET IN to RESET Delay
RESET IN Input Leakage Current
Open-Drain
RESET
Output
Voltage
Open-Drain
RESET
Output
Leakage Current
I
RESET IN
V
CC
≥
4.5V, I
SINK
= 3.2mA, reset asserted
V
OL
V
CC
≥
2.5V, I
SINK
= 1.2mA, reset asserted
V
CC
≥
1.0V, I
SINK
= 80µA, reset asserted
I
LKG
V
CC
> V
TH
,
RESET
not asserted
V
CC
≥
4.5V, I
SINK
= 3.2mA, reset asserted
V
OL
Push-Pull
RESET
Output Voltage
V
OH
V
CC
≥
2.5V, I
SINK
= 1.2mA, reset asserted
V
CC
≥
1.0V, I
SINK
= 80µA, reset asserted
V
CC
≥
4.5V, I
SOURCE
= 800µA, reset not
asserted
V
CC
≥
2.5V, I
SOURCE
= 500µA, reset not
asserted
V
CC
≥
4.5V, I
SOURCE
= 800µA, reset asserted
V
CC
≥
2.5V, I
SOURCE
= 500µA, reset asserted
V
OH
V
CC
≥
1.8V, I
SOURCE
= 150µA, reset asserted
Push-Pull RESET Output Voltage
V
CC
≥
1.0V, I
SOURCE
= 1µA, reset asserted
V
CC
≥
4.5V, I
SINK
= 3.2mA, reset not
asserted
V
OL
V
CC
≥
2.5V, I
SINK
= 1.2mA, reset not
asserted
0.8 x
V
CC
0.8 x
V
CC
0.8 x
V
CC
0.8 x
V
CC
0.8 x
V
CC
0.8 x
V
CC
0.4
0.3
V
RESETIN
falling at 4mV/µs from
V
THRST
+ 40mV to V
THRST
- 40mV
-50
32
500
1.245
1.232
1.219
4.5
±1
+50
0.4
0.3
0.3
1.0
0.4
0.3
0.3
V
µA
V
SYMBOL
CONDITIONS
MIN
1
100
200
63
1560
1.27
100
3000
1.295
1.308
1.321
µs
nA
V
TYP
MAX
UNITS
µs
ns
ns
kΩ
Ω
MAX6381–MAX6390
V
Note 1:
Specifications over temperature are guaranteed by design, not production tested.
I am a newbie. Today I got a project to take over. One of the sub-projects is a static libaray project, but the generated file is a .a file. Isn't it usually a .lib file? What is a .a file?...
I am making a thing now, called a networked water pipe leak detection system, but I don't know how to do the leak detection part. I may not be able to make an ultrasonic flow meter. Is there a water p...
[align=left][color=rgb(0, 0, 0)][font="][size=12px] Hello, I want to make a high-frequency PFC. The frequency is 1-2MHz, PF and efficiency are >90%. The output is about 100W, and the input voltage is ...
I picked up the goods from the Cainiao Post Station yesterday at noon today. Here are the unpacking photos:It was a good board, but when I powered it on, I saw nothing. I thought I had plugged it in t...
Calibrators are widely used in university experiments. Among them, there are two experiments in nuclear physics experiments in modern physics experiments (GM counter and β absorption) that require ...[Details]
Although improper medical device product design is not always associated with medical device-related errors. Studies of users have shown that lack of adequate training accounts for 70% to 90% of suc...[Details]
For more than 10 years, analog-to-digital converters (ADCs) have been widely used in industrial process control, medical instruments, communication systems, radar and other products as a booster of in...[Details]
This article discusses how to use an ultra-low-power RF transceiver chip from Zarlink Semiconductor for pacemakers, neurostimulators, drug pumps, and other such implantable medical devices t...[Details]
JTAG Technology Introduction
One disadvantage of shrinking technology is that the complexity of testing small devices increases dramatically. When the board area is large, the board is tested...[Details]
TD-SCDMA terminal conformance test includes three types of tests: RF index test (reference standard: 3GPPTS34.122), protocol signaling test (reference standard: 3GPPTS34.123) and other tests (refer...[Details]
Overview
Currently, many portable consumer electronic products, such as mobile phones, PDAs, MP3 players, and notebooks, are equipped with display screens. Although the type and size of the di...[Details]
Multi-parameter monitor is an important device in clinical nursing. It can monitor the patient's ECG, blood pressure, blood oxygen saturation, respiratory rate, pulse rate and temperature. At present,...[Details]
introduction
The data detected by various
measuring instruments
often need to be transferred to a PC for data processing and archiving, so as to make full use of the rich hardware an...[Details]
A correct circuit design cannot be manufactured 100% correctly when it is taken to the factory for manufacturing. It will always be affected by various uncertainties, such as deviations in manufact...[Details]
Introduction
High voltage power supply is an indispensable part of nuclear radiation detection instrument, which supplies high voltage to nuclear radiation detection devices (such as prop...[Details]
Most
embedded
systems are powered from a 48V backplane. This voltage is typically stepped down to a lower intermediate bus voltage of 24V, 12V, or 5V to power the circuit board racks withi...[Details]
Industrial control
often requires multi-channel fault detection and multi-channel command control (this multi-task setting is very common). A single CPU chip is difficult to directly complete ...[Details]
0 Introduction
Implantable medical devices can be divided into two types: passive and active. Most passive implantable medical devices are non-electronic products, such as contact lenses, hear...[Details]
Capacitive sensing user interfaces are emerging as a practical and innovative alternative to mechanical buttons in mobile phones. While capacitive sensors can be viewed as a drop-in replacement fo...[Details]