Choice between differential PECL or TTL clock input
s
Single +5V power supply
s
V
BB
output for single-ended use
s
Multiple power and ground pins to minimize noise
s
Specified within-device skew
s
Fully compatible with MC10H/100H606
s
Available in 28-pin PLCC package
The SY10/100H606 are 6-bit, registered, single supply
TTL-to-PECL translators. The devices feature differential
PECL outputs as well as a choice between either a
differential PECL clock input or a TTL clock input. The
asynchronous master reset control is a PECL level input.
With its differential ECL outputs and TTL inputs, the
H606 device is ideally suited for the transmit function of
a HPPI bus-type board-to-board interface application. The
on-chip registers simplify the task of synchronizing the
data between the two boards.
The device is available in either ECL standard: the
10H device is compatible with 10K logic levels, while the
100H device is compatible with 100K logic levels.
BLOCK DIAGRAM
PIN NAMES
Pin
D
0
– D
5
Function
TTL Data Inputs
Differential PECL Clock Inputs
TTL Clock Input
PECL Master Reset Input
True PECL Outputs
Inverted PECL Outputs
PECL V
CC
(5.0V)
TTL V
CC
(5.0V)
TTL/PECL Ground
V
BB
Reference Output (PECL)
1 OF 6 BITS
D
n
D
Q
Q
n
Q
n
CLK, CLK
TCLK
MR
Q
0
– Q
5
Q
0
– Q
5
CLK
R
V
CCE
V
CCT
GND
V
BB
CLK
CLK
TCLK
MR
V
BB
M9999-032906
hbwhelp@micrel.com or (408) 955-1690
1
Rev.: E
Amendment: /0
Issue Date: March 2006
Micrel, Inc.
SY10H606
SY100H606
PACKAGE/ORDERING INFORMATION
D
2
V
CCT
D
3
V
CCE
Ordering Information
(1)
Part Number
Package
Type
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
Operating
Range
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Package
Marking
SY10H606JC
SY10H606JC
SY100H606JC
SY100H606JC
Lead
Finish
Sn-Pb
Sn-Pb
Sn-Pb
Sn-Pb
25 24 23 22 21 20 19
D
1
D
4
D
5
D
0
TCLK
V
BB
CLK
CLK
MR
V
CCE
26
27
28
1
2
3
4
5
6
7
8
9
10 11
18
17
16
Q
5
Q
5
Q
4
Q
4
V
CCE
Q
3
Q
3
SY10H606JC
SY10H606JCTR
(2)
SY100H606JC
SY100H606JCTR
(2)
SY10H606JZ
(3)
SY10H606JZTR
(2, 3)
SY100H606JZ
(3)
SY100H606JZTR
(2, 3)
Notes:
TOP VIEW
PLCC
15
14
13
12
SY10H606JZ with
Matte-Sn
Pb-Free bar-line indicator
SY10H606JZ with
Matte-Sn
Pb-Free bar-line indicator
SY100H606JZ with
Matte-Sn
Pb-Free bar-line indicator
SY100H606JZ with
Matte-Sn
Pb-Free bar-line indicator
Q
0
Q
0
GND
Q
1
Q
1
28-Pin PLCC (J28-1)
Q
2
Q
2
1. Contact factory for die availability. Dice are guaranteed at T
A
= 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032906
hbwhelp@micrel.com or (408) 955-1690
2
Micrel, Inc.
SY10H606
SY100H606
TRUTH TABLE
Dn
L
H
X
MR
L
L
H
TCLK/CLK
Z
Z
X
Qn + 1
L
H
L
Z = Low to High Transition.
DC ELECTRICAL CHARACTERISTICS
V
CCT
= V
CCE
= 5.0V
±5%
T
A
= 0
°
C
Symbol
I
CCTL
I
CCTH
I
GND
Parameter
Supply Current
Supply Current
Supply Current
Min.
—
—
—
Typ.
18
13
75
Max.
30
25
90
—
—
—
T
A
= +25
°
C
Min.
Typ.
18
13
75
Max.
30
25
90
—
—
—
T
A
= + 85
°
C
Min.
Typ.
18
13
75
Max.
30
25
95
Unit
mA
mA
mA
Condition
Outputs LOW
Outputs HIGH
TTL DC ELECTRICAL CHARACTERISTICS
V
CCT
= V
CCE
= 5.0V
±5%
T
A
= 0
°
C
Symbol
V
IH
V
IL
V
IK
I
IH
I
IL
Parameter
Input HIGH Voltage
Input LOW Voltage
Input Clamp Voltage
Input HIGH Current
Input LOW Current
Min.
2.0
—
—
—
—
—
Max.
—
0.8
–1.2
20
100
–0.6
T
A
= +25
°
C
Min.
2.0
—
—
—
—
—
Max.
—
0.8
–1.2
20
100
–0.6
T
A
= + 85
°
C
Min.
2.0
—
—
—
—
—
Max.
—
0.8
–1.2
20
100
–0.6
Unit
V
V
V
µA
mA
I
IN
= –18mA
V
IN
= 2.7V
V
IN
= 7.0V
V
IN
= 0.5V
Condition
10H PECL DC ELECTRICAL CHARACTERISTICS
(1)
V
CCT
= V
CCE
= 5.0V
±5%
T
A
= 0
°
C
Symbol
I
IH
I
IL
V
IH
V
IL
V
OH
V
OL
V
BB
Parameter
Input HIGH Current
Input LOW Current
Input HIGH Voltage
Input LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output Bias Voltage
Min.
—
0.5
3830
3050
3980
3050
3620
Max.
225
—
4160
3520
4160
3370
3730
T
A
= +25
°
C
Min.
—
0.5
3870
3050
4020
3050
3650
Max.
145
—
4190
3520
4190
3370
3750
T
A
= + 85
°
C
Min.
—
0.5
3930
3050
4080
3050
3690
Max.
145
—
4280
3555
4270
3400
3810
Unit
µA
µA
mV
mV
mV
mV
mV
V
CCT
= 5.0V
V
CCT
= 5.0V
V
CCT
= 5.0V
V
CCT
= 5.0V
V
CCT
= 5.0V
Condition
Note:
1. PECL VIL, VIH, VOL, VOH, VBB are given for VCCT = VCCE = 5.0V and will vary 1:1 with power supply.
M9999-032906
hbwhelp@micrel.com or (408) 955-1690
3
Micrel, Inc.
SY10H606
SY100H606
100H PECL DC ELECTRICAL CHARACTERISTICS
(1)
V
CCT
= V
EEC
= 5.0V
±5%
T
A
= 0
°
C
Symbol
I
IH
I
IL
V
IH
V
IL
V
OH
V
OL
V
BB
Parameter
Input HIGH Current
Input LOW Current
Input HIGH Voltage
Input LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output Bias Voltage
Min.
—
0.5
3835
3190
3975
3190
3620
Max.
225
—
4120
3525
4120
3380
3740
T
A
= +25
°
C
Min.
—
0.5
3835
3190
3975
3190
3620
Max.
145
—
4120
3525
4120
3380
3740
T
A
= + 85
°
C
Min.
—
0.5
3835
3190
3975
3190
3620
Max.
145
—
4120
3525
4120
3380
3740
Unit
µA
µA
mV
mV
mV
mV
mV
V
CCT
= 5.0V
V
CCT
= 5.0V
V
CCT
= 5.0V
V
CCT
= 5.0V
V
CCT
= 5.0V
Condition
Note:
1. PECL V
IL
, V
IH
, V
OL
, V
OH
, V
BB
are given for V
CCT
= V
CCE
= 5.0V and will vary 1:1 with power supply.
AC ELECTRICAL CHARACTERISTICS
V
CCT
= V
CCE
= 5.0V
±5%
T
A
= 0
°
C
Symbol
t
PD
t
PD
t
PD
t
PD
t
PD
t
S
t
H
t
PW
t
PW
t
r
t
f
t
RES/REC
Parameter
Propagation Delay
TCLK+ +
Propagation Delay
TCLK+ –
Propagation Delay
CLK+ +
Propagation Delay
CLK+ –
Propagation Delay
MR+ –
Set-up Time
Hold Time1.5
Minimum Pulse Width
CLK
Minimum Pulse Width
MR
Rise/Fall Time
Reset/Recovery Time
Min. Typ.
0.800
0.800
0.800
0.800
0.800
1.5
0.5
1.5
1.5
—
2.5
—
—
—
—
—
0.5
—
—
—
—
2.0
Max.
T
A
= +25
°
C
Min.
Typ.
—
—
—
—
—
0.5
—
1.0
—
1.0
2.0
Max.
T
A
= + 85
°
C
Min. Typ.
—
—
—
—
—
0.5
—
—
—
—
2.0
Max.
2.800
2.800
2.800
2.800
2.800
—
ns
—
—
2.0
—
ns
ns
ns
ns
Unit
ns
ns
ns
ns
ns
ns
Condition
2.800 0.800
2.800 0.800
2.800 0.800
2.800 0.800
2.800 0.800
—
1.5
—
—
2.0
—
1.5
0.5
1.5
1.5
—
2.5
2.800 0.800
2.800 0.800
2.800 0.800
2.800 0.800
2.800 0.800
—
1.5
—
—
2.0
—
1.5
0.5
1.5
1.5
—
2.5
M9999-032906
hbwhelp@micrel.com or (408) 955-1690
4
Micrel, Inc.
SY10H606
SY100H606
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
USA
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.