EEWORLDEEWORLDEEWORLD

Part Number

Search

KLLU700.X

Description
industrial & electrical fuses 700a 600vac class L
CategoryCircuit protection    Circuit protection   
File Size186KB,3 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric Compare View All

KLLU700.X Overview

industrial & electrical fuses 700a 600vac class L

KLLU700.X Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
Circuit protection typeELECTRIC FUSE
Manufacturer's serial numberKLLU
Base Number Matches1
General Purpose Fuses
KLLU Class L Fuses
600 VAC • Time-Delay • 601 – 4000 Amperes
Applications
Service switches
Switchboard mains and feeders
Bolted pressure contact switches
Motor control center mains
Large motor branch circuits
UL Listed series rated protection for molded case circuit breaker
panelboards and loadcenters. See panelboard manufacturers’
literature for recommended fuse rating.
General Purpose Fuses
Safety
• 200,000 A.I.R. — Provides reliable interruption of all overcurrents up
to 200,000 amperes.
• When used for motor branch circuit protection, KLLU fuses may be
sized close to the motor full load current, providing excellent protection
to branch circuit conductors, motor control equipment and motors.
Longer Equipment Life
• Current-Limiting — Reduces short-circuit damage to systems and
equipment.
• Reduced downtime.
• Ten second minimum time-delay at 500% current eliminates
needless downtime caused by heavy starting currents of large
motors and other inductive loads.
• Selective coordination — KLLU fuses coordinate well with other
Class L fuses and with all current-limiting Littelfuse fuses rated 600
amps or less. This means less time spent trying to locate short-
circuits or overloaded equipment, because only the fuse immediately
on the line side of the affected circuit opens.
KLLU series UL Listed, time-delay, Class L fuses are quality fuses,
developed to provide a somewhat lower priced alternate to the
POWR-PRO
®
KLPC series fuses. KLLU series fuses meet or exceed
all UL requirements for Class L fuses. For superior protection and
performance, specification-grade POWR-PRO KLPC series fuses are
the recommended fuse. Complete information on KLPC fuses may
be found in the POWR-PRO Fuse section of this catalog.
Easy To Use
• 200,000 A.I.R. rating minimizes need for short-circuit calculations,
while meeting present and future system requirements.
• KLLU fuse time-current characteristics closely match typical time-
current curves of circuit breakers. Although fuse/circuit breaker systems
can seldom be 100% coordinated, KLLU series fuses permit use of a
wider range of breaker setting than fast acting Class L fuses.
Excellent protection for a single breaker or a group of breakers.
Specifications
Voltage Ratings:
Interrupting Ratings:
Ampere Range:
Approvals:
AC: 600 Volts
DC: Contact factory
200,000 am­peres rm­s sym­m­etrical
601 – 4000 am­peres
Standard 248-10, Class L
UL Listed (File No: E81895)
CSA Certified (File No: LR29862)
Ampere Ratings
601
650
700
750
800
900
1000
1200
1350
1400
1500
1600
1800
2000
2500
3000
3500
4000
Exam­ple part num­ber (series & am­perage): KLLU 1000
26
www.littelfuse.com
© 2005 Littelfuse
POWR-GARD
Products Catalog

KLLU700.X Related Products

KLLU700.X KLLU900.X KLLU800.X
Description industrial & electrical fuses 700a 600vac class L industrial & electrical fuses 900a 600vac class L industrial & electrical fuses 800a 600vac class L
Reach Compliance Code unknow unknow unknow
Circuit protection type ELECTRIC FUSE ELECTRIC FUSE ELECTRIC FUSE
Manufacturer's serial number KLLU KLLU KLLU
Base Number Matches 1 1 1
Manual Soldering Techniques for Surface Mount Components
Now more and more circuit boards use surface mount components. Compared with traditional packaging, it can reduce the area of the circuit board, is easy to process in large quantities, and has high wi...
yuandayuan6999 PCB Design
Help!!!!!!!!!!!! The problem of STM32 IO speed and instruction execution speed? ?
72Mhz STM32, PLCK2 = 72Mhz , tested with a logic analyzer, the speed is 0.24us/instruction, theoretically it should be 0.14us/instruction (simulator verification). May I ask why the speed is so slow? ...
zxdplay stm32/stm8
How to draw PCB antenna using PADS?
I already know the size of the PCB antenna. How do I draw the PCB antenna using PADS? Should I use the traces directly or draw the copper foil? And how do I set the two ends of the traces to not have ...
golf_zhao PCB Design
Transfer ARM development board
I bought a smart arm2200 development block last month.,,,I have read it several times, and with the strong technical support of Zhou Ligong (if I don't understand something, I can just call and get an...
hupl ARM Technology
Follow Equ subscription account "Smart Hardware" and get a free 8G USB flash drive (award has been issued)
[align=center][align=left][font=微软雅黑][size=3]The winner of this issue's USB flash drive: [color=#06699][url=https://home.eeworld.com.cn/space-uid-487244.html]an736007364[/url][/color] Congratulations:...
eric_wang Talking
Welcome to join the C\C++ in-depth analysis group
Linux C qt C++ enthusiasts please join 256401284...
OnlyCxue Linux and Android

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2420  2285  1826  2896  191  49  47  37  59  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号