*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
PTR90 Series - 9 mm Multi-Ganged Potentiometer w/Rotary Switch
Product Dimensions
PTR904
23.3
±
0.5
(.917
±
.020)
PTR906
30.8
±
0.5
(1.213
±
.020)
PTR908
38.3
±
0.5
(1.508
±
.020)
M7XP0.75
SW
R4 R3
R2 R1
0.8
±
0.2
(.014
±
.007)
5.0
(.197)
SW
R6 R5
R4 R3
R2 R1
6.25
(.246)
2.5
(.098)
5.0
(.197)
6.25
(.246)
2.5
(.098)
5.0
(.197)
2.5
(.098)
5.0
(.197)
2.5
(.098)
M7XP0.75
0.8
±
0.2
(.014
±
.007)
5.0
(.197)
SW
R8 R7
R6 R5
R4 R3
R2 R1
M7XP0.75
0.8
±
0.2
(.014
±
.007)
6.25
(.246)
2.5
(.098)
5.0
(.197)
2.5
(.098)
5.0
(.197)
5.0
(.197)
2.5
(.098)
RECOMMENDED PCB LAYOUT
2.5
(.098)
6.25
(.246)
3
2
1
3
2
1
5.0
(.197)
2.5
(.098)
3
2
1
3
2
1
5.0
(.197)
RECOMMENDED PCB LAYOUT
2.5
(.098)
5.0
(.197)
2.5
(.098)
6.25
(.246)
3
3
2
1
3
2
1
3
2
1
2
1
2.5
(.098)
5.0
(.197)
5.0
(.197)
RECOMMENDED PCB LAYOUT
2.5
(.098)
2.5
(.098)
3
2
1
3
2
1
5.0
(.197)
2.5
(.098)
5.0
(.197)
5.0
(.197)
2.5
(.098)
5.0
(.197)
MOUNTING
SURFACE
DIA. HOLES
14 PLCS.
1.0 +0.2/-0
(.039 +.008/-0)
5.0
SW
(.197)
5.0
SW
(.197)
R4 R3
R2 R1
MOUNTING
SURFACE
DIA. HOLES
20 PLCS.
1.0 +0.2/-0
(.039 +.008/-0)
2.5
(.098)
6.25
(.246)
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
2.5
(.098)
3
2
1
3
2
1
R6 R5
R4 R3
R2 R1
5.0
(.197)
SCHEMATIC
3
3
3
3
SCHEMATIC
3
3
3
3
3
3
SW
MOUNTING
SURFACE
R8 R7
R6 R5
R4 R3
R2 R1
5.0
(.197)
2
DIA. HOLES
26 PLCS.
1.0 +0.2/-0
(.039 +.008/-0)
2
2 2
2
2
2 2
2 2
SCHEMATIC
3 3
3
3
3
3
3
3
1
SW
R4
1
R3
1
R2
1
R1
SW
1
1
1
1
1
1
2
2 2
2 2
2 2
2
R6 R5
R4 R3
R2 R1
DIMENSIONS:
MM
(INCHES)
1 1
SW
R8 R7
1 1
R6 R5
1 1
R4 R3
1 1
R2 R1
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
PTR90 Series - 9 mm Multi-Ganged Potentiometer w/Rotary Switch
Product Dimensions
SHAFT STYLE
"K"
SHAFT STYLE
"F"
L
±
B
18 TEETH
KNURL
F
0.5
(.020)
How To Order
PTR90 1 - 2 0 20 K - B 203
Model
• PTR90 = With
Rotary Switch
No. of Sections
• 1 = 1 Section
• 2 = 2 Sections
• 3 = 3 Sections
• 4 = 4 Sections
• 5 = 5 Sections
• 6 = 6 Sections
• 8 = 8 Sections
Pin Style
• 1 = PC Pins vertical/
down facing
and ±10 %
Total Resistance
Tolerance
•2=
PC Pins vertical/
down facing
and ±20 %
Total Resistance
Tolerance
L
±
B
0.5
(.020)
1.5
(.059)
A
1.0
(.039)
6.0 +0/-0.1
(.236 +0/-.004)
DIA.
30
°
9.5
±
0.3
(.374
±
.012)
6.0
(.236)
4.8
±
0.3
(.189
±
.012)
9.5
±
0.3
(.374
±
.012)
4.5
(.177)
4.5
(.177)
6.0 +0/-0.1
(.236 +0/-.004)
DIA.
60
°
4.8
±
0.3
(.189
±
.012)
6.5
±
0.3
(.256
±
.012)
0.8
(.031)
2.0
(.079)
0.8
(.031)
6.0
(.236)
3.5
(.138)
5.0
(.197)
0.8
(.031)
2.0
(.079)
0.8
(.031)
6.5
±
0.3
(.256
±
.012)
Center Detent Option
• 0 = No Detent
• 2 = Center Detent
3.5
(.138)
5.0
(.197)
Standard Shaft Length
• 15 = 15 mm
• 20 = 20 mm
• 25 = 25 mm
Shaft Styles
• K = Knurled Type Shaft (Metal)
18 Toothed Serration Type
• F = Flatted Metal Shaft
Resistance Taper (See Taper Charts)
Taper Series followed by Curve Number
Resistance Code (See Table)
Other shaft styles available.
SHAFT SHOWN IN CCW POSITION
SHAFT SHOWN IN CCW POSITION
L
B
A
15
(.591)
5
(.197)
6
(.236)
20
(.787)
7
(.276)
10
(.394)
25
(.984)
10
(.394)
12
(.472)
L
B
F
15
(.591)
5
(.197)
7
(.276)
20
(.787)
7
(.276)
12
(.472)
25
(.984)
10
(.394)
12
(.472)
DIMENSIONS:
MM
(INCHES)
Tapers
A Series Tapers
100
90
80
Terminal 1-2 Output Voltage
X 100 (%)
Terminal 1-3 Input Voltage
70
60
50
40
30
20
10
A6
A5
):
:
0A
A)
(3
(25
A4
A ) :
A3
(20
A):
(15
A
A):
(10
A): A1
(05
B Series Tapers
100
B1
C Series Tapers
100
): B
5
): B
(2B
3
): B
2
(B
):
(1B
B
):
90
80
Terminal 1-2 Output Voltage
X 100 (%)
Terminal 1-3 Input Voltage
70
60
50
40
30
20
10
90
80
Terminal 1-2 Output Voltage
X 100 (%)
Terminal 1-3 Input Voltage
70
60
50
40
30
20
10
(3
(25 0C):
C
C
(20 ): C 6
5
(15 C):
C) C4
:
(1 C3
(05 0C):
C
C)
:C
1
(5B
0
10
20
30
40
50
60
70
80
90
100
(4B
): B
4
(3B
0
10
20
30
40
50
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
Rotational Travel (%)
Rotational Travel (%)
Rotational Travel (%)
REV. 01/14
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
As part of the meter-free system, frequency measurement is used to monitor the water consumption of the water meter. Today's code measures the frequency of the PWM signal sent by the speed sensor. The...
The anti-interference design of printed circuit boards is closely related to the specific circuits. Here we will only explain several common measures for PCB anti-interference design. 1. Power line de...
AREAInit, CODE, READONLYCODE32; --- Standard definitions of mode bits and interrupt (I & F) flags in PSRs
Mode_USREQU0x10
Mode_FIQEQU0x11
Mode_IRQEQU0x12
Mode_SVCEQU0x13
Mode_ABTEQU0x17
Mode_UNDEQU0x1...
In early 2002, I started to write a working program for an IC card prepaid electricity meter. The meter used Philips' 8-bit 51-expanded single-chip microcomputer
87LPC764
, and wa...[Details]
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data, the...[Details]
No matter which processor you are learning, the first thing you need to understand is the registers and working mode of the processor.
ARM has 37 registers, including 31 general registers and ...[Details]
Abstract: In order to generate a stable excitation signal, the design of a digital frequency synthesizer is implemented on FPGA using Verilog hardware language. The design includes accumulator, wav...[Details]
When choosing a laptop battery, you should consider several factors, such as power, appearance, and quality.
Regarding power, we often see that a manufacturer uses values such as the number ...[Details]
1 Introduction
Intelligent control instruments are one of the most commonly used controllers in industrial control. They are mainly aimed at a specific parameter (such as pressure, tempera...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
In recent years, with the rapid development of the information industry, dot matrix LED display screens have been widely used in various advertising and information display systems such as the fina...[Details]
This controller uses PIC16C54 single-chip microcomputer as the controller, and it is very easy to use: just connect a telephone line to the loudspeaker through the controller, and you can rem...[Details]
Today, the value of electronic components in cars accounts for 15-20% of the total vehicle. In the future, this proportion may be as high as 30-40% as more safety electronics, fuel consumption and ...[Details]
Today, with energy becoming increasingly scarce, the utilization of natural energy has become the focus of people's attention. Among various natural energies, the endless solar energy is highly fav...[Details]
With the widespread application of new services and technologies in the communications industry, the scale and capacity of operators' network construction are getting larger and larger, and the ris...[Details]
0 Introduction
In order to improve the automation control of shortwave transmitters, so that they can automatically process from far to near, the technicians here use the ICS system to complete the ...[Details]
With the continuous advancement of various technologies in the field of measurement and control, the baseband subsystem of general measurement and control equipment has entered the fourth generation o...[Details]