EEWORLDEEWORLDEEWORLD

Part Number

Search

5220.0243.3

Description
AC power entry modules filtered fused 2A
CategoryThe connector    The connector   
File Size584KB,5 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric Compare View All

5220.0243.3 Overview

AC power entry modules filtered fused 2A

5220.0243.3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompli
ECCN codeEAR99
Factory Lead Time7 weeks
Other featuresSTANDARDS: IEC/EN 60320-1/C14, UL 498, CSA C22.2, VDE, QUICK CONNECT
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings2A, 250/125VAC
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Power Entry Modules with Line Filter
www.schurter.com/PG06
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole
5220
Plug removal necessary for fuse
replacement
Typ 5220, Fuseholder 2-pole
Screw-On Version
Typ 5220, Fuseholder 2-pole
Snap-In Version
C14
70° C
Description
- Panel Mount:
Snap-in or screw-on mounting from front side
- 3 Functions:
Appliance Inlet Protection class I, Fuseholder for fuse-links 5 x 20 mm
2-pole, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
- All single elements are already wired
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Approvals
References
Weblinks
- VDE Certificate Number: 101307
- UL File Number: E72928
Alternative: version without line filter
6220
Alternative: Standard version
pdf-datasheet, html-datasheet, General Product Information, RoHS,
CHINA-RoHS, REACH, Mating Connectors, e-Shop, SCHURTER-
Stock-Check, Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC 60320,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
2-pole, Shocksafe category PC2 acc. to
IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 1.6 W (2-pole)
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 2'300'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Filter
MTBF
Material: Housing
Connectors
1

5220.0243.3 Related Products

5220.0243.3 PA0693 5220.0643.3 5220.0443.3 5220.0423.6 5220.0123.1 5220.0423.1 5220.0823.1 5220.0123.3
Description AC power entry modules filtered fused 2A HIGH FREQUENCY PLANAR TRANSFORMERS AC power entry modules snap-IN 2-pole 6A AC power entry modules snap-IN 2-pole 4A AC power entry modules G-stecker-kombi 4A med AC power entry modules 5220 pwr entry modul W. filter 1A AC power entry modules 5220 pwr entry modul W. filter 4A AC power entry modules 5220 pwr entry modul W. filter 8A AC power entry modules 5220 pwr entry modul W. filter 1A M5
Is it lead-free? Lead free - Lead free Lead free - Lead free Lead free Lead free Lead free
Is it Rohs certified? conform to - conform to conform to - conform to conform to conform to conform to
package instruction ROHS COMPLIANT - ROHS COMPLIANT ROHS COMPLIANT - ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT
Reach Compliance Code compli - compliant compliant - compliant compliant compliant compliant
ECCN code EAR99 - EAR99 EAR99 - EAR99 EAR99 EAR99 EAR99
Factory Lead Time 7 weeks - 7 weeks 7 weeks - 7 weeks 7 weeks 7 weeks 7 weeks
Other features STANDARDS: IEC/EN 60320-1/C14, UL 498, CSA C22.2, VDE, QUICK CONNECT - STANDARDS: IEC/EN 60320-1/C14, UL 498, CSA C22.2, VDE, QUICK CONNECT STANDARDS: IEC/EN 60320-1/C14, UL 498, CSA C22.2, VDE, QUICK CONNECT - STANDARDS: IEC/EN 60320-1/C14, UL 498, CSA C22.2, VDE, QUICK CONNECT STANDARDS: IEC/EN 60320-1/C14, UL 498, CSA C22.2, VDE, QUICK CONNECT STANDARDS: IEC/EN 60320-1/C14, UL 498, CSA C22.2, VDE, QUICK CONNECT STANDARDS: IEC/EN 60320-1/C14, UL 498, CSA C22.2, VDE, QUICK CONNECT
Body/casing type SOCKET - SOCKET SOCKET - SOCKET SOCKET SOCKET SOCKET
Connector type MAINS POWER CONNECTOR - MAINS POWER CONNECTOR MAINS POWER CONNECTOR - MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR
Contact to complete cooperation NOT SPECIFIED - NOT SPECIFIED NOT SPECIFIED - NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Contact point gender MALE - MALE MALE - MALE MALE MALE MALE
Contact material NOT SPECIFIED - NOT SPECIFIED NOT SPECIFIED - NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Coupling type SNAP - SNAP SNAP - SNAP SNAP SNAP SNAP
DIN compliance NO - NO NO - NO NO NO NO
IEC compliance YES - YES YES - YES YES YES YES
MIL compliance NO - NO NO - NO NO NO NO
Power Connector Ratings 2A, 250/125VAC - 6A, 250/125VAC 4A, 250/125VAC - 1A, 250/125VAC 4A, 250/125VAC 8A, 250/125VAC 1A, 250/125VAC
Plug information MULTIPLE MATING PARTS AVAILABLE - MULTIPLE MATING PARTS AVAILABLE MULTIPLE MATING PARTS AVAILABLE - MULTIPLE MATING PARTS AVAILABLE MULTIPLE MATING PARTS AVAILABLE MULTIPLE MATING PARTS AVAILABLE MULTIPLE MATING PARTS AVAILABLE
Installation type PANEL - PANEL PANEL - PANEL PANEL PANEL PANEL
Options GENERAL PURPOSE - GENERAL PURPOSE GENERAL PURPOSE - GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE
Shell material POLYETHYLENE - POLYETHYLENE POLYETHYLENE - POLYETHYLENE POLYETHYLENE POLYETHYLENE POLYETHYLENE
Termination type SOLDER - SOLDER SOLDER - SOLDER SOLDER SOLDER SOLDER
Total number of contacts 3 - 3 3 - 3 3 3 3
Base Number Matches 1 - 1 1 - 1 1 1 1
Maker - - SCHURTER SCHURTER - SCHURTER SCHURTER SCHURTER SCHURTER
About antenna receiving power and power amplification
Question 1: For an antenna, the energy sent out is dBm, and the unit of the received energy should still be dBm. The problem is that even when entering the PCB, the signal received should still be a v...
呜呼哀哉 RF/Wirelessly
About IAR
I am using IAR Embedded Workbench v5.11. Note that it is v5.11. The board is ADuC7026. The program compiles and links fine, but debugging always fails with the message: unable to get contact with Rom-...
hd12 Embedded System
No response to TCP connection to Vxworks?
No response to the TCP connection of Vxworks. That is, after the first SYN packet of the three-way handshake was sent to the Vxworks system (sent using Telnet on XP on the Host), the system did not re...
李红磊 Real-time operating system RTOS
Application program reads .txt file in WinCE and it is garbled
Write an MFC-based application that runs under WinCE and reads the contents of a .txt file. The structure is as follows: Book title 1; Price 1 Book title 2; Price 2 Book title 3; Price 3 ... CFile myf...
力量 Embedded System
【Repost】Altera SoC FAQ
[align=left][b][font=宋体][size=14.0pt]SOC[/size][/font][/b][b][font=宋体][size=14.0pt]FAQ[/size][/font][/b][/align][align=left][font=宋体][size=10.5pt] [/size][/font][/align][align=left][b][color=red][font...
chenzhufly FPGA/CPLD
2017, Accumulate & Grow Together: Share Sensor Use Experience, Looking Forward to Your Joining
[size=4][font=微软雅黑]I feel sorry for the experience and discussion of using sensors that are drowned in QQ groups. Although they are just a few words, they are also precious. [/font] I have specially o...
nmg ST Sensors & Low Power Wireless Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 105  1059  2152  1721  59  3  22  44  35  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号