Eliminates the need for traditional flooding compound
and provides efficient and craft-friendly cable preparation
Dielectric central strength member
No preferential bend and requires no bonding or ground-
ing
Medium-density polyethylene jacket
Makes cable rugged and durable while being flexible and
easy to strip
ALTOS
®
Lite™ single-jacket, single-armored cables,
enhanced are lightweight, reduced-diameter, armored
cables designed for direct burial, duct and aerial (lashed)
installation. The loose tube design provides stable perfor-
mance over a wide temperature range and is compatible
with any telecommunications-grade optical fiber.
Standards
Design and Test Criteria
ANSI/ICEA S-87-640
Telcordia GR-20
RDUP PE-90
Ripcord
Dielectric Central
Element
Fiber
Buffer
Tube
Water-Swellable
Tape
Corrugated Steel
Armor
Polyethylene (PE)
Outer Jacket
ALTOS Lite Single-Jacket, Single-Armored Cables,
72 Fibers, Enhanced
| Photo PIM2518
Family Spec Sheet 0091_NAFTA_AEN
Page 1 | Revision date 2014-07-01
ALTOS Lite Single-Jacket, Single-Armored Cables,
72 Fibers, Enhanced
| Photo PIMtbd
ALTOS
®
Lite™ Single-Jacket, Single-
Armored Cables, 12-432 Fibers, Enhanced
Ripcord
Water-Swellable
Tape
Dielectric Central
Element
Fiber
Buffer
Tube
Water-Swellable
Tape
Corrugated Steel
Armor
Polyethylene (PE)
Outer Jacket
ALTOS Lite Single-Jacket, Single-Armored Cables,
288 Fibers, Enhanced
| Photo PIM2523
ALTOS Lite Single-Jacket, Single-Armored Cables,
288 Fibers, Enhanced
| Photo PIMtbd
Specifications
Temperature Range
Storage
Installation
Operation
-40 °C to 70 °C (-40 °F to 158 °F)
-30 °C to 70 °C (-22 °F to 158 °F)
-40 °C to 70 °C (-40 °F to 158 °F)
*
Note: Corning recommends storing cable in a proper temperature environment prior to installation to allow the cable temperature to meet installation tempera-
ture range specifications for best installation results.
Max. Tensile Strength, Short-Term
Max. Tensile Strength, Long-Term
2700 N (600 lbf)
890 N (200 lbf)
Mechanical Characteristics Cable
Fiber Count
Product Type Number of
Tube Posi-
tions
Armored
Armored
Armored
6
8
12
Number of
Weight
Active Tubes
1-6
8
12
136 kg/km
(91 lb/1000 ft)
173 kg/km
(116 lb/1000 ft)
262 kg/km
(176 lb/1000 ft)
Nominal
Outer Dia-
meter
12.1 mm
(0.48 in)
13.8 mm
(0.54 in)
17.5 mm
(0.69 in)
Min. Bend
Radius
Installation
182 mm
(7.1 in)
207 mm
(8.1 in)
263 mm
(10.3 in)
Min. Bend
Radius Ope-
ration
121 mm
(4.8 in)
138 mm
(5.4 in)
175 mm
(6.9 in)
12 - 72
96
144
Family Spec Sheet 0091_NAFTA_AEN
Page 2 | Revision date 2014-07-01
ALTOS
®
Lite™ Single-Jacket, Single-
Armored Cables, 12-432 Fibers, Enhanced
Mechanical Characteristics Cable
Fiber Count
Product Type Number of
Tube Posi-
tions
Armored
Armored
Armored
18
24
36
Number of
Weight
Active Tubes
16 - 18
24
30 - 36
256 kg/km
(172 lb/1000 ft)
323 kg/km
(217 lb/1000 ft)
400 kg/km
(269 lb/1000 ft)
Nominal
Outer Dia-
meter
17.7 mm
(0.70 in)
20.0 mm
(0.79 in)
23.2 mm
(0.91 in)
Min. Bend
Radius
Installation
266 mm
(10.5 in)
300 mm
(11.8 in)
348 mm
(13.7 in)
Min. Bend
Radius Ope-
ration
177 mm
(7.0 in)
200 mm
(7.9 in)
232 mm
(9.1 in)
192 - 216
288
360 - 432
Chemical Characteristics
RoHS
Free of hazardous substances according to RoHS 2002/95/
EG
Transmission Performance
Multimode
Fiber Core Diameter
(
µm
)
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Serial 1 Gigabit Ethernet
(
m
)
Serial 10 Gigabit Ethernet
(
m
)
Min. Overfilled Launch (OFL)
Bandwidth
(
MHz*km
)
Minimum Effective Modal
Bandwidth (EMB)
(
MHz*km
)
62.5
OM1
K
30
850/1300
3.4/1.0
300/550
33/-
200/500
220/-
50
OM2
T
31
850/1300
3.0/1.0
750/500
150/-
700/500
950/-
50
OM3
T
80
850/1300
3.0/1.0
1000/600
300/-
1500/500
2000/-
50
OM4
T
90
850/1300
3.0/1.0
1100/600
550/-
3500/500
4700/-
Family Spec Sheet 0091_NAFTA_AEN
Page 3 | Revision date 2014-07-01
ALTOS
®
Lite™ Single-Jacket, Single-
Armored Cables, 12-432 Fibers, Enhanced
Single-mode
Fiber Name
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Typical Attenuation*
(
dB/km
)
Fiber Name
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Typical Attenuation*
(
dB/km
)
SMF-28e+
®
fiber
G.652.D
E
00
1310/1383/1550
0.35/0.35/0.25
0.33/0.33/0.19
SMF-28
®
ULL
G.652
P
19
1310/1383/1550
0.33/-/0.19
0.31/-/0.17
SMF-28e+
®
fiber
G.652.D
E
01
1310/1383/1550
0.4/0.4/0.3
0.33/0.33/0.19
LEAF
®
G.655
F
01
1310/1383/1550
-/-/0.25
-/-/0.19
SMF-28e+
®
LL
G.652.D
L
22
1310/1383/1550
0.34/0.34/0.22
0.32/0.32/0.18
SMF-28
®
Ultra**
ClearCurve
®
XB**
G.652.D/G.657.A1 G.652.D/G.657.A1
Z
22
1310/1383/1550
0.34/0.34/0.22
0.32/0.32/0.18
H
01
1310/1383/1550
0.4/0.4/0.3
0.35/0.35/0.20
*
Typical attenuation values match the attenuation values listed in the optical fiber specifications. See
www.corning.com/opticalfiber
for Corning optical fiber
specifications. Better attenuation performance options are available for some fiber and cable types. Contact Customer Care for additional fiber options.
*
* SMF-28
®
Ultra and ClearCurve
®
XB fiber deliver up to 10x better macrobend loss performance compared to the G.652.D standard and up to 33 percent better
macrobend loss performance than the G.657.A1 standard for 10mm radii bends.
Family Spec Sheet 0091_NAFTA_AEN
Page 4 | Revision date 2014-07-01
ALTOS
®
Lite™ Single-Jacket, Single-
Armored Cables, 12-432 Fibers, Enhanced
Ordering Information |
Note: Contact Customer Care at 1-800-743-2675 for other options.
1) Cable outer diameter may change. Example: 48 F cable with 6 fibers per tube will require 8 active buffer and have an OD like a standard 96 F cable.
Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA
After the flyback power supply has been replaced with a transformer, the waveform of the rectifier diode has become composed of a bunch of small wavy waveforms. The following are the pictures of the r...
I hope to achieve the following functions: When booting, read the data num in the flash. When the initialization program runs, the value of num will change. When the run ends, store the value of num i...
When configuring a pin interrupt, it cannot be in digital output mode, otherwise the interrupt configuration will fail.If you want to use the internal pull-up/pull-down of the pin, you need to configu...
On August 24th, Jin Yuzhi, CEO of Huawei's Intelligent Automotive Solutions BU, announced the first automotive application of Huawei Qiankun's unique Limera technology. This technology eliminates t...[Details]
Limited vocabulary recognition
According to the number of characters, words or short sentences in the vocabulary, it can be roughly divided into: less than 100 is small vocabulary; 100-1000 is...[Details]
We are entering a new era where people are increasingly affordably equipped with more electronic gadgets. Electronics have become essential to our lives. For example, the average consumer now owns ...[Details]
As time goes by, people are increasingly concerned about their own and their families' health. However, existing monitoring devices for individual vital signs have struggled to gain market share du...[Details]
Logic analyzers are widely used tools in digital design verification and debugging. They can verify the proper functioning of digital circuits and help users identify and troubleshoot faults. They ...[Details]
Core point: The automotive industry chain and the humanoid robot industry have collaborative advantages in hardware, software, and scenarios. Upstream and downstream companies in the automotive ind...[Details]
For autonomous vehicles to safely navigate the road, they must identify far more complex objects than just traffic lights, pedestrians, and other familiar objects. Among these obstacles is a crucia...[Details]
As AI accelerates across industries, the demand for data center infrastructure is also growing rapidly.
Keysight Technologies, in collaboration with Heavy Reading, released the "Beyo...[Details]
Pure electric vehicles, structurally speaking, have components such as a power battery. In addition to the power battery, a small battery also powers some low-voltage electrical components and even...[Details]
With the advent of the electric car era, the number of pure electric vehicles has increased significantly, but many car owners do not know how to properly maintain pure electric vehicles. In additi...[Details]
With the continuous development of the industrial automation industry, we are seeing an increasing number of intelligent devices using flexible, efficient, and precise robotic arms to p...[Details]
As the range of electric vehicles continues to increase, driving electric vehicles for long-distance travel has become a trend. For high-speed travel, how much impact will high-speed driving of ele...[Details]
Renesas Electronics' new ultra-low-power RA4C1 MCU features advanced security and a dedicated peripheral set, making it ideal for metering and other applications.
The new product mee...[Details]
On August 18th, China's largest expressway
charging station,
the G25 Changshen Expressway Tonglu Service Area (South Area), officially opened and launched its integrated solar-storage-charg...[Details]
With the growth of the Internet of Things (IoT), wearable, and portable devices, consumers are growing weary of cluttered cables and the need for frequent battery recharges. The benefits of wireles...[Details]