L11-B2-22-410-47A-KA

Description
Magnetic Circuit Breaker,
CategoryCircuit protection    Circuit protection   
File Size2MB,8 Pages
ManufacturerCarling Technologies
Environmental Compliance
Download Datasheet Parametric View All

L11-B2-22-410-47A-KA Overview

Magnetic Circuit Breaker,

L11-B2-22-410-47A-KA Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7347397937
Reach Compliance Codecompliant
Country Of OriginMexico
YTEOL7.9
Actuator typeROCKER
Other featuresSTANDARDS: MIL-PRF-55629, MIL-STD-202
body width19.05 mm
body height49.4 mm
Body length or diameter92.58 mm
circuit functionSERIES TRIP
Circuit protection typeMAGNETIC CIRCUIT BREAKER
Environmental characteristicsMOISTURE RESISTANT
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Rated breaking capacity5000 A
Rated current1 A
Rated voltage (AC)120 V
surface mountNO
Terminal shapeSCREW
L-Series
Circuit Breaker
Available with Current Transformer
The L-Series high performance, compact hydraulic-
magnetic circuit breaker is ideally suited for the rigors and
confined spaces found in today’s telecom/datacom power
distribution units and rack systems. It provides best in class
performance in an innovative low profile, space saving
package complementing the overall spatial objectives
required by telecommunications and data-communications
systems designers in their quest to reduce the overall size
of equipment, while increasing transmission capacity.
The optional current transformer allows outlet metering
and monitoring of power usage thus facilitating load
adjustments and maximizing efficiency.
Further, a patent
pending flush rocker actuator design and optional push-to-
reset guard offers additional protection against accidental
switching.
Number of poles: 1-3. Maximum current and voltage
ratings: .2-32A, 120/240-240VAC. Maximum interrupting
capacity: 5000 Amps
Applications:
Š
Telecom/Datacom Industry
– Power Distribution Units
– Data Servers
– Data Storage
Product Highlights:
Š
Optional current transformer
Š
Ultra low profile design saves valuable space
Š
Optional handle guard actuator
Š
UL 489 LISTED Branch Circuit breaker
Š
Designed for worldwide datacenter
compatibility with up to 240VAC ratings
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
Problems with using DSP for DCDC
Does anyone know why PID control is used when using DSP for DCDC? Is it okay if PID control is not used?...
40001752006 Integrated technical exchanges
Information about distortion meter
[i=s]This post was last edited by paulhyde on 2014-9-15 09:39[/i] Information about the distortion meter, everyone is welcome to download....
fpga126 Electronics Design Contest
Happy New Year of the Rooster! On the first day of the Lunar New Year, I wish you all a happy New Year~~~
[size=3]:congratulate:Happy New Year! Happy New Year~~~On the first day of the Lunar New Year, okhxyyo is here to wish you all a happy New Year~~[/size] [size=3] [/size][size=4][color=#ff0000][b]Wish ...
okhxyyo Talking
Experts who are familiar with 7135 are welcome to explain and discuss if interested.
[i=s]This post was last edited by Wuhuaizai on 2021-9-1 13:38[/i]The internal block diagram of the ADC ICL7135 is as follows. After the A/Z process closes the internal circuit, the circuit diagram is ...
呜呼哀哉 Analog electronics
What causes it?
This is a test program for serial port reception with checksum. In the checksum, when it runs to return 1, it starts from the beginning instead of entering if. What is the reason for this? void main()...
ena 51mcu
Internal Hardware Resources of PIC Microcontroller 16F84 (Part 3)
PIC Microcontroller16F84 's Internal Hardware Resources (Part 3)...
rain Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1186  926  1923  742  2754  24  19  39  15  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号