Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/min
Approved Safety Standards
Consult your OMRON sales representative for specific
models with safety standard approvals.
UL (UL508)/
CSA
(CSA C22.2 No.55)
Rated voltage
125 VAC
250 VAC
Model
J-7
7A
7A
Note. Consult your OMRON sales representative for specific models with safety
standard approvals.
1
J
Characteristics
Permissible operating speed
Permissible operating
frequency
Insulation resistance
Contact resistance (initial value)
Between terminals of the same polarity
Dielectric strength
Between current-carrying metal parts and ground
Between each terminals and non-current-carrying metal parts
Vibration resistance *1
Shock resistance *1
Durability *2
Degree of protection
Ambient operating temperature
Ambient operating humidity
Weight
Malfunction
Durability
Malfunction
Mechanical
Electrical
Mechanical
Electrical
400 operations/min max.
30 operations/min max.
Subminiature Basic Switch
0.05 mm to 1 m/s (for pin plunger models)
100 mΩ min. (at 500 VDC with insulation tester)
15 mΩ max.
600 VAC 50/60 Hz for 1 min
1,500 VAC 50/60 Hz for 1 min
1,500 VAC 50/60 Hz for 1 min
10 to 55 Hz, 1.5 mm double amplitude
1,000 m/s
2
max.
200 m/s
2
max. (pin plunger models)
10,000,000 operations min. (60 operations/min)
50,000 operations min. (30 operations/min)
IEC IP40
-10°C to
+80°C
(at ambient humidity of 60% max.)
(with no icing or condensation)
85% max. (for
+5°C
to
+35°C)
Approx. 1 g (pin plunger models)
J
Note. The data given above are initial values.
*1. For the pin plunger models, the above values apply for use at the free position, operating position, and total travel position. For the lever models, they apply for
the total travel position. Close or open circuit of the contact is shorter than 1 ms.
*2. For testing conditions, consult your OMRON sales representative.
Dimensions
(Unit: mm)
and Operating Characteristics
●Pin
Plunger
J-7
3.5 dia.
1.5 dia.
A
PT
R0.8
Operating Characteristics
Operating Force
Releasing Force
8.9
Models
Max.
Min.
Max.
Min.
Max.
J-7
1.37 N {140 gf}
0.27 N {28 gf}
0.6 mm
0.1 mm
0.15 mm
8.1±0.3 mm
OP
2.3
2.35
+0.05
-0.025
0.05
2.5
+0.05
dia.
-0.025
OF
RF
PT
OT
MD
OP
5.1
1 dia.
1.5 dia.
5.1
±0.1
Pretravel
Overtravel
Movement Differential
Operating Position
3.95
4.8
±0.05
12.7
2.35
+0.05
dia.
-0.025
●Short
Hinge Lever
J-7-V
9.3
R12.7
±0.4
A t=0.3*
PT
2.3
Operating Characteristics
Operating Force
Releasing Force
OF
RF
PT
OT
MD
OP
Models
Max.
Min.
Max.
Min.
Max.
J-7-V
0.49 N {50 gf}
0.09 N {9 g}
1.7 mm
0.35 mm
0.5 mm
8.3±1.2 mm
9.15
±0.4
8
2.3
2.35
+0.05
-0.025
+0.05
2.5
-0.025
dia.
-0.025
6.6
OP
5.1
1 dia.
1.5 dia.
5.1
±0.1
Pretravel
Overtravel
Movement Differential
Operating Position
3.95
4.8
±0.05
12.7
14.7
2.35
+0.05
dia.
-0.025
* Stainless-steel lever
●Hinge
Lever
J-7-V3
9.15
±0.4
8
9.3
t=0.3*
R22
±0.4
A
PT
2.3
Operating Characteristics
6.6
2.3
2.35
+0.05
-0.025
0.05
2.5
+0.05
dia.
-0.025
Models
Max.
Min.
Max.
Min.
Max.
J-7-V3
0.29 N {30 gf}
0.05 N {5 gf}
2.9 mm
0.5 mm
0.7 mm
8.3±1.9 mm
OP
Operating Force
Releasing Force
Pretravel
Overtravel
Movement Differential
1 dia.
1.5 dia.
5.1
±0.1
OF
RF
PT
OT
MD
OP
5.1
Operating Position
3.95
4.8
±0.05
12.7
14.7
2.35
+0.05
dia.
-0.025
* Stainless-steel lever
Note 1. Unless otherwise specified, a tolerance of
±0.2
mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
2
J
●Long
Hinge Lever
J-7-V4
9.3
t=0.3*
R33.8
±0.4
A
PT
2.3
Subminiature Basic Switch
Operating
Characteristics
Operating Force
Releasing Force
OF
RF
Models
Max.
Min.
J-7-V4
0.20 N {20 gf}
0.03 N {3 gf}
4.5 mm
0.8 mm
1.2 mm
8.3±2.9 mm
9.15
±0.4
8
2.3
2.35
+0.05
-0.025
0.05
2.5
+0.05
dia.
-0.025
6.6
OP
5.1
1 dia.
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
Operating Position
OP
3.95
4.8
±0.05
12.7
14.7
2.35
+0.05
dia.
-0.025
* Stainless-steel lever
5.1
±0.1
1.5 dia.
J
●Short
Hinge Roller Lever
J-7-V22
9.3
A
PT
4.8x2.2* dia.
R11.5
±0.4
OP
9.15
±0.4
8
8.9
2.3
2.35
+0.05
-0.025
2.8
0.05
2.5
+0.05
dia.
-0.025
Operating
Characteristics
Operating Force
Releasing Force
OF
RF
Models
Max.
Min.
J-7-V22
0.54 N {55 gf}
0.05 N {5 gf}
1.6 mm
0.25 mm
0.4 mm
14.7±1 mm
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
Operating Position
1 dia.
OP
3.95
4.8
±0.05
12.7
14.7
2.35
+0.05
dia.
-0.025
5.1
±0.1
1.5 dia.
* Stainless-steel lever
Stainless-steel roller
●Hinge
Roller Lever
J-7-V2
9.3
A
R20.5
±0.4
PT
4.8x2.2* dia.
Operating
Characteristics
Operating Force
Releasing Force
OF
RF
Models
Max.
Min.
J-7-V2
0.33 N {33 gf}
0.03 N {3 gf}
2.7 mm
0.45 mm
0.7 mm
14.7±1.9 mm
OP
9.15
±0.4
8
2.3
2.35
+0.05
-0.025
0.05
2.5
+0.05
dia.
-0.025
0.025
6.6
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
Operating Position
OP
5.1
1 dia.
1.5 dia.
5.1
±0.1
* Stainless-steel lever
Stainless-steel roller
3.95
4.8
±0.05
12.7
14.7
2.35
+0.05
dia.
-0.025
Note 1. Unless otherwise specified, a tolerance of
±0.2
mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
Precautions
★
Please refer to "Common Precautions" for correct use.
Caution
●Soldering
• Terminal connection
When soldering, make sure that the temperature of the
soldering iron tip is not higher than 280°C, and complete the
soldering within 3 seconds. Leave it for 1 minute without
applying any external force to the terminal after the soldering.
Soldering at an excessively high temperature or soldering for
more than 3 s may deteriorate the characteristics of the
Switch.
Correct Use
●Mounting
Use M2.3 mounting screw with plane washers or spring washers
to securely mount the Switch. Tighten the screws to a torque of
0.2 to 0.29 N·m {2 to 3 kgf·cm}.
3
J
Subminiature Basic Switch
J
•
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
•
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
Write it down to deepen my understanding. I hope some newbies can see it and get some inspiration. I write down my little things. Finally I feel that I have made some progress. Haha. I will work harde...
There are N array antennas. The signal received by each array element is S(t)*exp(jnu). When the corresponding weighted value is exp(-jnu), the output Y is N*S(t). If noise filtering is considered and...
If I add a new module (such as codec) to the board, and set its registers through I2C, there is already an I2C device driver for this IC, but what should I do if I want to set this IC in other driver ...
[font=微软雅黑][size=4]PADS LAYOUT shortcut key summary, [/size][/font] [font=微软雅黑][size=4]This post is organized by the original post: [/size][/font][url=https://bbs.eeworld.com.cn/forum.php?mod=viewthre...
Basic skills and applications of PIC32 microcontrollers : https://training.eeworld.com.cn/course/1952Demonstrates basic skills of the PIC32 microcontroller and how to use it in your projects....
With the rapid development of science and technology, especially the widespread application of digital technology and various ultra-large-scale integrated circuits, electronic equipment, especially...[Details]
As LEDs continue to improve in almost every aspect of performance and cost, LED lighting is being used in an increasingly wide range of applications, among which LED street lights are a focus of in...[Details]
This paper establishes a fuel cell engine test platform based on the NI integrated hardware and software environment. This platform can realize the test and control of fuel cell engines and their a...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
12v Lead Acid batteries used in trucks, cars, RVs and uninterruptible power supplies are usually rated at 12V. This circuit monitors the battery, the charge and discharge curves, gives the cu...[Details]
introduction
MAX6636 is a multi-channel precision temperature monitor that can not only monitor local temperature, but also connect up to 6 diodes externally. Each channel has a programmable...[Details]
introduction
MEMS is a high-tech that has flourished on the basis of integrated circuit production technology and dedicated micro-electromechanical processing methods. Pressure sensors develop...[Details]
D5026A is a driver IC designed by Shanghai Debei Electronics for energy-saving LED display screens. Its design concept is energy-saving and compatible with existing solutions, that is, it can be ...[Details]
System Overview
The system consists of a signal preprocessing circuit, a single-chip computer AT89C2051, a systematic LED display module, a serial port data storage circuit and system software...[Details]
introduction
Steam turbines are driven by high-temperature and high-pressure steam generated by boilers to run at high speed. They are key power equipment in thermal power plants. The emergenc...[Details]
As the global LED market demand continues to increase, my country's LED industry will face huge opportunities in the future. However, the core LED technology and patents are basically monopolized b...[Details]
One in five car failures are caused by batteries, a problem that will become more serious in the coming years as electric-by-wire, start/stop engine management and hybrid (electric/gas) vehicles be...[Details]
DCDC means DC to DC (conversion of different DC power values). Anything that meets this definition can be called a DCDC converter. Specifically, it means converting the input DC into AC through a s...[Details]
Features
POE technology can ensure the safety of existing structured cabling while ensuring the normal operation of the existing network and minimizing costs. The IEEE 802.3af standard is ...[Details]
This paper describes the design method of electronic multifunctional watt-hour meter, the key technology of hardware design and the software design process. Taking NEC's μPD78F0338 microcontroller ...[Details]