GE
12V PicoTLynx
TM
3A: Non-Isolated DC-DC Power Module
4.5Vdc –14Vdc input; 0.59Vdc to 5.5Vdc output; 3A Output Current
Features
Data Sheet
Compliant to RoHS EU Directive 2002/95/EC (Z versions)
Compatible in a Pb-free or SnPb reflow environment (Z
versions)
DOSA based
Wide Input voltage range (4.5Vdc-14Vdc)
Output voltage programmable from 0.59Vdc to 5.5Vdc
via external resistor
Tunable Loop
TM
to optimize dynamic output voltage
response
Flexible output voltage sequencing EZ-SEQUENCE (APTS
versions)
Remote sense
Power Good signal
Fixed switching frequency
Output overcurrent protection (non-latching)
Overtemperature protection
Remote On/Off
Ability to sink and source current
Cost efficient open frame design
Small size: 12.2 mm x 12.2 mm x 6.25 mm
(0.48 in x 0.48 in x 0.246 in)
Wide operating temperature range [-40°C to
105°C(Ruggedized: -D), 85°C(Regular)]
UL*
60950-1Recognized,
CSA
†
C22.2 No. 60950-1-03
Certified, and
VDE
‡
0805:2001-12 (EN60950-1) Licensed
ISO** 9001 and ISO 14001 certified manufacturing
facilities
RoHS Compliant
EZ-SEQUENCE
TM
Applications
Distributed power architectures
Intermediate bus voltage applications
Telecommunications equipment
Servers and storage applications
Networking equipment
Industrial equipment
VIN
PGOOD
SEQ
CTUNE
Q1
Vout+
Vin+
VOUT
SENSE
RTUNE
MODULE
Cin
Co
ON/OFF
GND
TRIM
RTrim
Description
The 12V PicoTLynx
TM
3A power modules are non-isolated dc-dc converters that can deliver up to 3A of output current. These
modules operate over a wide range of input voltage (V
IN
= 4.5Vdc-14Vdc) and provide a precisely regulated output voltage from
0.59Vdc to 5.5Vdc, programmable via an external resistor. Features include remote On/Off, adjustable output voltage, over
current and overtemperature protection, and output voltage sequencing (APTS versions). The Ruggedized version (-D) is capable
of operation up to 105°C and withstand high levels of shock and vibration. A new feature, the Tunable Loop
TM
, allows the user to
optimize the dynamic response of the converter to match the load with reduced amount of output capacitance leading to
savings on cost and PWB area.
*
UL
is a registered trademark of Underwriters Laboratories, Inc.
†
‡
CSA
is a registered trademark of Canadian Standards Association.
VDE
is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
May 2, 2013
©2013 General Electric Company. All rights reserved.
GE
4.5Vdc –14Vdc input; 0.59Vdc to 5.5Vdc output; 3A Output Current
Absolute Maximum Ratings
Data Sheet
12V PicoTLynx
TM
3A: Non-Isolated DC-DC Power Modules
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Sequencing Voltage
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
APTS
All
-D version
All
V
SEQ
T
A
T
A
T
stg
-0.3
-40
-40
-55
V
iN
85
105
125
Vdc
°C
°C
°C
Device
All
Symbol
V
IN
Min
-0.3
Max
15
Unit
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(V
IN
=4.5V to 14V, I
O
=I
O, max
)
Input No Load Current
(V
IN
= 12.0Vdc, I
O
= 0, module enabled)
Input Stand-by Current
(V
IN
= 12.0Vdc, module disabled)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN
=0 to 14V
,
I
O
=
I
Omax
; See Test Configurations)
Input Ripple Rejection (120Hz)
All
All
All
I
2
t
43
50
1
A
2
s
mAp-p
dB
V
O,set
= 0.6 Vdc
V
O,set
= 3.3Vdc
All
I
IN,No load
I
IN,No load
I
IN,stand-by
17
55
1
mA
mA
mA
Device
All
All
Symbol
V
IN
I
IN,max
Min
4.5
Typ
⎯
Max
14.0
3.5
Unit
Vdc
Adc
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of
sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum
safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating
of 5A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc
input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further
information.
May 2, 2013
©2013 General Electric Company. All rights reserved.
Page 2
GE
4.5Vdc –14Vdc input; 0.59Vdc to 5.5Vdc output; 3A Output Current
Electrical Specifications
(continued)
Parameter
Output Voltage Set-point (with 0.5% tolerance for external
resistor used to set output voltage)
Output Voltage (Over all operating input voltage, resistive load,
and temperature conditions until end of life)
Adjustment Range (selected by an external resistor)
(Some output voltages may not be possible depending on the
input voltage – see Feature Descriptions Section)
Remote Sense Range
Output Regulation (for V
O
≥
2.5Vdc)
Line (V
IN
=V
IN, min
to V
IN, max
)
Load (I
O
=I
O, min
to I
O, max
)
Temperature (T
ref
=T
A, min
to T
A, max
)
Output Regulation (for V
O
< 2.5Vdc)
Line (V
IN
=V
IN, min
to V
IN, max
)
Load (I
O
=I
O, min
to I
O, max
)
Temperature (T
ref
=T
A, min
to T
A, max
)
Remote Sense Range
Output Ripple and Noise on nominal output
(V
IN
=V
IN, nom
and I
O
=I
O, min
to I
O, max
Co = 0.1μF // 10
μF
ceramic
capacitors)
V
O
> 3.3V Peak-to-Peak (5Hz to 20MHz bandwidth)
RMS (5Hz to 20MHz bandwidth)
V
O
≤
3.3V Peak-to-Peak (5Hz to 20MHz bandwidth)
RMS (5Hz to 20MHz bandwidth)
External Capacitance
Without the Tunable Loop
TM
ESR
≥
1 mΩ
With the Tunable Loop
TM
ESR
≥
0.15 mΩ
ESR
≥
10 mΩ
1
Data Sheet
12V PicoTLynx
TM
3A: Non-Isolated DC-DC Power Modules
Device
All
All
All
All
All
All
All
All
All
All
All
Symbol
V
O, set
V
O, set
V
O
Min
-1.5
-3.0
0.59
Typ
Max
+1.5
Unit
% V
O, set
% V
O, set
Vdc
Vdc
% V
O, set
mV
% V
O, set
mV
mV
mV
V
⎯
+3.0
5.5
0.5
⎯
⎯
⎯
⎯
⎯
⎯
+0.4
10
+0.4
10
5
5
0.5
All
All
All
All
⎯
⎯
110
35
50
20
135
45
110
40
mV
pk-pk
mV
rms
mV
pk-pk
mV
rms
All
All
All
All
All
All
V
O,set
= 0.59Vdc
V
O, set
= 1.2Vdc
V
O,set
= 1.8Vdc
V
O,set
= 2.5Vdc
V
O,set
= 3.3Vdc
V
O,set
= 5.0Vdc
C
O, max
C
O, max
C
O, max
I
o
I
O, lim
I
O, s/c
η
η
η
η
η
η
f
sw
0
0
0
0
⎯
⎯
⎯
200
300
73.3
82.9
86.5
88.9
90.6
92.6
600
47
1000
3000
3
μF
μF
μF
Adc
% I
o,max
mA
%
%
%
%
%
%
Output Current
Output Current Limit Inception (Hiccup Mode )
Output Short-Circuit Current (V
O
≤250mV)
( Hiccup Mode )
Efficiency
V
IN
= 12Vdc, T
A
=25°C
I
O
=I
O, max ,
V
O
= V
O,set
Switching Frequency
Dynamic Load Response
(dIo/dt=10A/μs; V
IN
= V
IN, nom
; V
out
= 1.8V, T
A
=25°C)
Load Change from Io= 50% to 100% of Io,max; Co = 0
Peak Deviation
Settling Time (Vo<10% peak deviation)
Load Change from Io= 100% to 50%of Io,max: Co = 0
Peak Deviation
Settling Time (Vo<10% peak deviation)
1
All
⎯
⎯
kHz
All
All
All
All
V
pk
t
s
V
pk
t
s
220
60
240
60
mV
μs
mV
μs
External capacitors may require using the new Tunable Loop
TM
feature to ensure that the module is stable as well as getting the best
transient response. See the Tunable Loop
TM
section for details.
May 2, 2013
©2013 General Electric Company. All rights reserved.
Page 3
GE
4.5Vdc –14Vdc input; 0.59Vdc to 5.5Vdc output; 3A Output Current
General Specifications
Parameter
Calculated MTBF (I
O
=0.8I
O, max
, T
A
=40°C) Telcordia Issue 2 Method 1 Case 3
Device
APTS
APXS
Weight
⎯
Min
Typ
Data Sheet
12V PicoTLynx
TM
3A: Non-Isolated DC-DC Power Modules
Max
Unit
Hours
Hours
15,694,689
25,017,068
1.55 (0.0546)
⎯
g (oz.)
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.
Parameter
On/Off Signal Interface
(V
IN
=V
IN, min
to V
IN, max
; open collector or equivalent,
Signal referenced to GND)
Device is with suffix “4” – Positive Logic (See Ordering Information)
Logic High (Module ON)
Input High Current
Input High Voltage
Logic Low (Module OFF)
Input Low Current
Input Low Voltage
Device Code with no suffix – Negative Logic (See Ordering Information)
(On/OFF pin is open collector/drain logic input with
external pull-up resistor; signal referenced to GND)
Logic High (Module OFF)
Input High Current
Input High Voltage
Logic Low (Module ON)
Input low Current
Input Low Voltage
Turn-On Delay and Rise Times
(V
IN
=V
IN, nom
, I
O
=I
O, max ,
V
O
to within ±1% of steady state)
Case 1: On/Off input is enabled and then input power is
applied (delay from instant at which V
IN
= V
IN, min
until V
o
=
10% of V
o, set
)
Case 2: Input power is applied for at least one second and
then the On/Off input is enabled (delay from instant at
which Von/Off is enabled until V
o
= 10% of V
o, set
)
Output voltage Rise time (time for V
o
to rise from
10% of Vo, set to 90% of Vo, set)
Output voltage overshoot (T
A
= 25
o
C
V
IN
= V
IN, min
to V
IN, max
,I
O
= I
O, min
to I
O, max
)
With or without maximum external capacitance
Over Temperature Protection
(See Thermal Considerations section)
Tracking Accuracy
(Power-Up: 2V/ms)
(Power-Down: 2V/ms)
(V
IN, min
to V
IN, max
; I
O, min
to I
O, max
V
SEQ
< V
o
)
APTS
APTS
V
SEQ
–V
o
V
SEQ
–V
o
100
100
mV
mV
All
T
ref
140
°C
All
Tdelay
—
2
—
msec
All
All
I
IL
V
IL
—
-0.2
—
—
10
0.6
μA
Vdc
All
All
I
IH
V
IH
—
3.5
—
—
1
V
IN, max
mA
Vdc
All
All
I
IL
V
IL
⎯
-0.3
⎯
⎯
1
0.8
mA
V
All
All
I
IH
V
IH
3.5
⎯
⎯
10
V
IN,max
µA
V
Device
Symbol
Min
Typ
Max
Unit
All
Tdelay
—
2
—
msec
All
Trise
—
4
—
3.0
msec
% V
O, set
May 2, 2013
©2013 General Electric Company. All rights reserved.
Page 4
GE
4.5Vdc –14Vdc input; 0.59Vdc to 5.5Vdc output; 3A Output Current
Feature Specifications (cont.)
Parameter
Input Undervoltage Lockout
Turn-on Threshold
Turn-off Threshold
Hysteresis
PGOOD (Power Good)
Signal Interface Open Drain, V
supply
≤
5VDC
Output Voltage Limit for PGOOD
Pulldown resistance of PGOOD pin
All
All
90%
All
All
All
3.3
0.4
Device
Symbol
Min
Data Sheet
12V PicoTLynx
TM
3A: Non-Isolated DC-DC Power Modules
Typ
Max
Units
4.3
Vdc
Vdc
Vdc
110%
7
50
V
O, set
Ω
May 2, 2013
©2013 General Electric Company. All rights reserved.
Page 5