EEWORLDEEWORLDEEWORLD

Part Number

Search

D4C-3220

Description
Basic/quick action/limit switch limit switch
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size754KB,23 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric View All

D4C-3220 Online Shopping

Suppliers Part Number Price MOQ In stock  
D4C-3220 - - View Buy Now

D4C-3220 Overview

Basic/quick action/limit switch limit switch

D4C-3220 Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryBasic/Snap Action/Limit Switch
RoHSyes
typeLimi
Enclosed Switch
D4C
Compact Limit Switch That's Also
Thin and Highly Sealed
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy
confirmation of operation.
(Set by default to light for non-operation.)
VCTF cables with CE marking.
(Applicable only to standard models.)
Be sure to read
Safety Precautions
on page 13 to 14 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend
Standard Models
Pre-wired Models
Weather-resistant Models
D4C-@@@
(1) (2)(3)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
5: 0.1 A at 125 VAC (with LED indicator)
6: 0.1 A at 30 VDC (with LED indicator)
D4C-@0@@-@@@@@@
(1)
(2)
(3)
(4)
(1) Rated Current
1: 1 A at 125 VAC, 1 A at 30 VDC
(Without operation indicator)
2: 1 A at 125 VAC (with operation indicator)
3: 1 A at 30 VDC (with operation indicator)
D4C-@@@-P
(1)(2)(3) (4)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A at 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
(2) Actuator
01: Pin plunger
02: Roller plunger
31: Sealed plunger
32: Sealed roller plunger
24: Roller lever (high-sensitivity model)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
4: VCTF (3 m)
5: VCTF (5 m)
6: SJT(O) (3 m)
7: SJT(O) (5 m)
(3) Actuator
20: Roller lever
24: Roller lever (high-sensitivity model)
27: Adjustable roller lever
29: Adjustable rod lever
(3) Wiring Specifications
DK1EJ: Pre-wired models
(3 conductors: DC specification)
AK1EJ: Pre-wired models
(3 conductors: AC specification)
M1J: Connector models for ASI devices
(2 conductors: NO wiring)
(3) Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
20: Roller lever
24: Roller lever (high-sensitivity model)
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller
50: Plastic rod
60: Center roller lever
(4) Structure
P: Weather-resistant
(4) Cable length
03: 0.3 m
Wiring Specifications
Internal switch
COM
NC
NO
Connector
3
2
4
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
1
Friends who have worked on spwm, please come and discuss the phase issue, thank you
I would like to ask you how to change the phase when using the formula method (such as area method, irregular sampling method, regular sampling method) when doing spwm. Thank you very much...
sing146 stm32/stm8
ADI Reference Circuit Collection (3rd Edition); Organized by Circuit Application
What a big collection of ADI reference circuits. It's too big. Forum friends, please download it from the download center. Address: [url=https://download.eeworld.com.cn/detail/nmg/553986]https://downl...
nmg ADI Reference Circuit
PB compilation error 2
] Linking E:\WINCE500\platform\smdk2440\lib\ARMV4Ietail\FMD.lib BUILD: [01:0000000141:ERRORE] LINK : fatal error LNK1181: cannot open input file 'obj\ARMV4Ietail\ecc.obj' I think the path is wrong. Ho...
linlaser Embedded System
Bit Operation of TI MSP430 MCU
[p=25, null, left][color=#000]With the increasing number of MCU types, the range of our choices is also getting larger and larger. Many friends who used to work on 51 have started to look for new prey...
Jacktang Microcontroller MCU
DSP TMS320C6000 basic learning cmd file analysis
[table=98%] [tr][td][size=3][color=#a0522d] The CMD file in DSP is a linker command file (Linker Command File) with the suffix .cmd. Before analyzing the cmd file, you must first understand (1) the me...
Aguilera DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development