The actual product is marked differently from the image shown here.
∗
The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
■
List of Models
Package type
Contact form
Terminals
PCB terminals
DIP4
1a
(SPST-NO)
Surface-mounting terminals
20 V
Load voltage
(peak value)
*
Model
G3VM-21AR
G3VM-21DR
G3VM-21DR (TR)
Minimum package quantity
Number per stick Number per tape and reel
100
---
---
1,500
*
The AC peak and DC value are given for the load voltage.
■
Absolute Maximum Ratings
(Ta = 25
°
C)
Item
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Pulse ON current
Connection temperature
Dielectric strength between I/O (See note 1.)
Operating temperature
Storage temperature
Soldering temperature
Input
Output
Input
Symbol
I
F
I
FP
∆I
F
/°C
V
R
T
J
V
OFF
I
O
∆I
O
/°C
Iop
T
J
V
I-O
Ta
Tstg
---
Rating
30
1
−0.3
5
125
20
3
−30
9
125
2500
−40
to +85
−55
to +125
260
Unit
mA
A
mA/°C
V
°C
V
A
mA/°C
A
°C
Vrms
°C
°C
°C
Measurement conditions
100
µs
pulses, 100 pps
Ta
≥
25°C
Ta
≥
25°C
t = 100 ms, Duty = 1/10
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note:
1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■
Electrical Characteristics
(Ta = 25
°
C)
Item
Symbol Minimum Typical Maximum
LED forward voltage
V
F
1.18
1.33
1.48
Reverse current
I
R
---
---
10
Capacity between terminals
C
T
---
70
---
Trigger LED forward current
I
FT
---
0.7
3
Maximum resistance with output ON
R
ON
---
40
80
Current leakage when the relay is open
I
LEAK
---
---
1.0
Capacity between terminals
C
OFF
---
300
---
Capacity between I/O terminals
C
I-O
---
0.8
---
Insulation resistance between I/O terminals
R
I-O
1000
---
---
Turn-ON time
t
ON
---
1
5
Turn-OFF time
t
OFF
---
0.3
1
Output
Unit
V
µA
pF
mA
mΩ
µA
pF
pF
MΩ
ms
ms
Measurement conditions
I
F
= 10 mA
Note:
V
R
= 5 V
V = 0, f = 1 MHz
I
O
= 1 A
I
F
= 5 mA, I
O
= 2 A, t < 1s
V
OFF
= 20 V
V = 0, f = 1 MHz
f = 1 MHz, V
S
= 0 V
V
I-O
= 500 VDC, R
O
H
≤
60%
I
F
= 5 mA, R
L
= 200
Ω,
V
DD
= 20 V (See note 2.)
2. Turn-ON and Turn-OFF Times
I
F
1
2
4
3
R
L
V
DD
V
OUT
I
F
V
OUT
10%
t
ON
90%
t
OFF
1
G3VM-21AR/DR
■
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Load voltage
(AC peak/DC)
Operating LED forward current
Continuous load current
(AC peak/DC)
Operating temperature
Symbol
V
DD
I
F
I
O
Ta
Minimum
---
5
---
−20
Typical
---
10
---
---
Maximum
16
25
3
65
Unit
V
mA
A
MOS FET Relays
DIP
°C
■
Engineering Data
G3VM-21AR/DR
LED forward current vs.
Ambient temperature
I
F
- Ta
Continuous load current I
O
(A)
LED forward current I
F
(mA)
50
4
Continuous load current vs.
Ambient temperature
I
O
- Ta
LED forward current vs.
LED forward voltage
I
F
- V
F
LED forward current I
F
(mA)
100
Ta = 25°C
40
3
10
30
2
1
20
1
10
0.1
0
-40
-20
0
20
40
60
80
100
0
-40
0.01
-20
0
20
40
60
80
100
0
0.5
1
1.5
2
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
LED forward voltage V
F
(V)
Continuous load current vs.
On-state voltage
I
O
- V
ON
Continuous load current I
O
(A)
4
3
2
1
0
-1
-2
Ta = 25°C
I
F
= 5mA
On-state resistance vs.
Ambient temperature
R
ON
- Ta
On-state resistance R
ON
(mΩ)
I
O
= 2A
I
F
= 5mA, t < 1s
80
100
Trigger LED forward current vs.
Ambient temperature
I
FT
- Ta
Trigger LED forward current I
FT
(mA)
2
I
O
= 1A
t < 1s
60
1
40
20
-3
-4
-0.2
0
-0.1
0
0.1
0.2
-40
-20
0
20
40
60
80
100
0
-40
-20
0
20
40
60
80
100
On-state voltage V
ON
(V)
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
Turn ON, Turn OFF time vs.
LED forward current
t
ON
, t
OFF
- I
F
Turn ON, Turn OFF time t
ON
, t
OFF
(ms)
100
V
DD
= 20V
RL = 200
Ω
Ta = 25°C
10
Turn ON, Turn OFF time vs.
Ambient temperature
t
ON
, t
OFF
- Ta
Turn ON, Turn OFF time t
ON
, t
OFF
(ms)
V
DD
= 20V
RL = 200
Ω
I
F
= 5mA
10
100
Current leakage vs.
Ambient temperature
I
LEAK
- Ta
Current leakage I
LEAK
(nA)
100
V
OFF
= 20V
10
t on
1
1
t off
t on
1
t off
0.1
0.1
0.1
0.01
1
10
100
0.01
-40
0.01
-20
0
20
40
60
80
100
-40
-20
0
20
40
60
80
100
LED forward current I
F
(mA)
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
■
Safety Precautions
• Refer to
"Common Precautions"
for all G3VM models.
2
Appearance/Dimensions
■
Appearance
DIP (Dual Inline Package)
DIP4
Mold pin mark∗
DIP4
OMRON logo
Model name
Pin 1 mark
932
LOT No.
Note:
The actual product is marked differently from the image shown here.
∗
The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.
■
Dimensions
PCB Terminals
Weight: 0.25 g
(Unit: mm)
Surface-mounting Terminals
Weight: 0.25 g
2.54
PCB Dimensions
(Bottom View)
Four, 0.8-dia. holes
2.54
(0.61)
4.58
±
0.25
4.58
±0.25
6.4
±
0.25
7.62
±
0.25
0.8
±
0.25
3.65
+0.15
−
0.25
0.25
+0.1
−0.05
2.5 min.
1.2
±
0.15
0.5
±
0.1
2.54
±
0.25
7.85 to 8.80
6.4
±0.25
7.62
±0.25
3.65
+0.15
−0.25
1.0 min.
1.2
±0.15
2.54
±0.25
10.0 max.
1.0 min.
4.0
+0.25
−0.2
(1.52)
(0.61)
(1.52)
Actual Mounting Pad Dimensions
(Recommended Value, Top View)
2.54
8.3 to 8.8
Note:
The actual product is marked differently from the
image shown here.
1.3
1.5
•
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
•
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.