CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
IMPORTANT NOTE: All parameters having Min/Max specifications are guaranteed. Typical values are for information purposes only. Unless otherwise noted, all tests
are at the specified temperature and are pulsed tests, therefore: T
J
= T
C
= T
A
Open-Loop DC Electrical Specifications
PARAMETER
V
OS
DESCRIPTION
Input Offset Voltage
V
S
= ±15V, R
L
= 150Ω, T
A
= 25°C unless otherwise specified.
LIMITS
CONDITIONS
V
S
= ±5V, ±15V
TEMP
25°C
T
MIN
, T
MAX
MIN
TYP
2
MAX
10
15
10
0.5
5
10
5
25
35
50
55
0.2
5
5
75
95
0.2
5
5
500
250
500
250
1.5
3.0
2.5
±13.5
±3.5
±12
±11
±12
±13.5
1800
2000
mV
mV
µV/°C
µA
µA
µA
µA
dB
µA/V
µA/V
dB
µA/V
µA/V
kΩ
kΩ
kΩ
kΩ
MΩ
pF
V
V
V
V
V
UNITS
TC V
OS
+I
IN
Average Offset Voltage Drift (Note 1)
+Input Current
V
S
= ±5V, ±15V
Full
25°C
T
MIN
, T
MAX
-I
IN
-Input Current
V
S
= ±5V, ±15V
25°C
T
MIN
, T
MAX
CMRR
-ICMR
Common Mode Rejection Ratio
(Note 2)
-Input Current Common
Mode Rejection (Note 2)
Power Supply Rejection Ratio (Note 3)
-Input Current Power Supply Rejection
(Note 3)
Transimpedance (Note 4)
V
S
= ±5V, ±15V
V
S
= ±5V, ±15V
Full
25°C
T
MIN
, T
MAX
Full
25°C
T
MIN
, T
MAX
PSRR
-IPSR
R
OL
V
S
= ±15V
R
L
= 400Ω
V
S
= ±5V
R
L
= 150Ω
25°C
T
MIN
, T
MAX
25°C
T
MIN
, T
MAX
Full
25°C
+R
IN
+C
IN
CMIR
+Input Resistance
+Input Capacitance
Common Mode Input Range
V
S
= ±15V
V
S
= ±5V
25°C
25°C
25°C
T
MIN
, T
MAX
25°C
V
O
Output Voltage Swing
R
L
= 400Ω,
V
S
=±15V
R
L
= 150Ω,
V
S
=±15V
R
L
= 150Ω,
V
S
=±5V
25°C
T
MIN
, T
MAX
25°C
±3.0
±2.5
60
±3.7
V
V
I
SC
Output Short Circuit Current (Note 5)
V
S
= ±5V, V
S
= ±15V
100
150
mA
2
EL2260, EL2460
Open-Loop DC Electrical Specifications
PARAMETER
I
S
DESCRIPTION
Supply Current (Per Amplifier)
V
S
= ±15V, R
L
= 150Ω, T
A
= 25°C unless otherwise specified.
(Continued)
LIMITS
CONDITIONS
V
S
= ±15V
TEMP
25°C
T
MIN
, T
MAX
V
S
= ±5V
25°C
T
MIN
, T
MAX
R
OL
NOTES:
1. Measured from T
MIN
to T
MAX
.
2. V
CM
= ±10V for V
S
= ±15V and T
A
= Full
V
CM
= ±3V for V
S
= ±5V and T
A
= 25°C
V
CM
= ±2V for V
S
= ±5V and T
A
= T
MIN
, T
MAX
3. The supplies are moved from ±2.5V to ±15V.
4. The supplies are moved from ±2.5V to ±15V.
5. A heat sink is required to keep junction temperature below absolute maximum when an output is shorted.
6. The supplies are moved from ±2.5V to ±15V.
Transimpedance (Note 6)
V
S
= ±15V
R
L
= 400Ω
25°C
500
2000
5.4
MIN
TYP
7.5
MAX
11.0
11.0
8.5
8.5
mA
mA
mA
mA
kΩ
UNITS
Closed-Loop AC Electrical Specifications
V
S
= ±15V, A
V
= +2, R
F
= 560Ω, R
L
= 150Ω, T
A
= 25°C unless otherwise noted
LIMITS
UNITS
MAX
MHz
MHz
MHz
MHz
V/µs
V/µs
PARAMETER
BW
DESCRIPTION
-3dB Bandwidth (Note 1)
TEST CONDITIONS
V
S
= ±15V, A
V
= +2
V
S
= ±15V, A
V
= +1
V
S
= ±5V, A
V
= +2
V
S
= ±5V, A
V
= +1
MIN
TYP
130
180
100
110
SR
Slew Rate (Note 1) (Note 2)
R
L
= 400Ω
R
F
= 1kΩ, R
G
= 110Ω
R
L
= 400Ω
1000
1500
1500
t
R
, t
F
t
PD
OS
t
S
Rise Time, Fall Time (Note 1)
Propagation Delay (Note 1)
Overshoot (Note 1)
0.1% Settling Time (Note 1)
V
OUT
= ±500mV
2.7
3.2
ns
ns
%
ns
V
OUT
= ±500mV
V
OUT
= ±10V
A
V
= -1, R
L
= 1k
0
35
dG
Differential Gain (Note 1)(Note 3)
R
L
= 150Ω
R
L
= 500Ω
0.025
0.006
0.1
0.005
%
%
deg (°)
deg (°)
dP
Differential Phase (Note 1)(Note 3)
R
L
= 150Ω
R
L
= 500Ω
NOTES:
1. All AC tests are performed on a “warmed up” part, except for Slew Rate, which is pulse tested.
2. Slew Rate is with V
OUT
from +10V to -10V and measured at the 25% and 75% points.
3. DC offset from -0.714V through +0.714V, AC amplitude 286mV
[size=4][color=#ff0000]The author started from grid paper and talked about the characteristics of various software from his experience. [/color][/size] [size=4][color=#000000][backcolor=white][font=si...
I read a piece of text from a file and display it in another window. However, when I use hard code, it can be displayed smoothly, but the value in the variable cannot be displayed (the value I get fro...
[align=left][font="][size=10.5pt][size=4][color=red]Extra Special[/color][/size][/size][/font]{:1_144:}[/align] [align=left][font="][size=10.5pt][size=4]The first 100 people to complete the experience...
Oracle database users are provided with the industry's first power management software, PowerChute plus , which is specially designed for the safe automatic shutdown of Oracle8 database server systems...
In recent years, with the increasing demand for manufacturing and automated production management, industrial barcode scanners have gradually become an indispensable part of the industrial manufact...[Details]
EtherCAT (Ethernet for Control Automation Technology) is a real-time industrial fieldbus communication protocol based on an Ethernet-based development framework. EtherCAT is one of the fastest indu...[Details]
To enable real-time monitoring of home security and automatically dial a number for voice prompts or send text messages when an alarm occurs, a GPRS-based embedded telephone alarm system was design...[Details]
Some time ago, I attended the 4th Energy Chemistry Forum of the Chinese Chemical Society and learned about high-energy-density and high-safety batteries. I would like to summarize and share this wi...[Details]
When we travel in cities, we all find that electric vehicles have many advantages. As a means of transportation, they can also fulfill their mission well. Now, more and more residential communities...[Details]
Limited vocabulary recognition
According to the number of characters, words or short sentences in the vocabulary, it can be roughly divided into: less than 100 is small vocabulary; 100-1000 is...[Details]
Recently, AstroBo Robot, a subsidiary of Chenxing Automation, launched a new mobile collaborative palletizing product. Leveraging an omnidirectional mobile chassis, an intelligent scheduling system...[Details]
Recently, South Korean robotics giant WIRobotics launched its first general-purpose humanoid robot, ALLEX, at the Robotics Innovation Center (RIH) at the Korea University of Science and Technology....[Details]
introduction
The concept of the smart home is gradually developing and gaining market acceptance. We believe its ultimate form lies in the interconnection of all home appliances through open i...[Details]
Electric vehicles are becoming increasingly popular, with increasingly longer ranges. There are two ways to charge electric vehicles: slow charging and fast charging. Which is the most suitable? Sl...[Details]
Based on the commutation technology, thyristor rectifiers are classified into two main types. Line-commutated and force-commutated inverters are commonly used, while other commutated inverters, nam...[Details]
Methods of DC motor speed regulation:
1. The voltage regulator can be used to change the input voltage and speed directly, which is often used for large kilowatt-level motors.
2. Thyristo...[Details]
There are many motors that can use thyristor speed control, and they can be used in almost all industries. Various types of motors, such as fans, pumps, AC motors, DC motors, torque motors, single-...[Details]
As the range of electric vehicles continues to increase, driving electric vehicles for long-distance travel has become a trend. For high-speed travel, how much impact will high-speed driving of ele...[Details]
For today's new energy vehicles, they have different configurations from fuel vehicles, and some configurations have also become a selling point for manufacturers. Compared with traditional vehicle...[Details]