EEWORLDEEWORLDEEWORLD

Part Number

Search

177-740-5-100CS0J5-18RDN

Description
Cable Assembly, 30AWG,
CategoryThe connector    Connector bracket   
File Size858KB,5 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance
Download Datasheet Parametric View All

177-740-5-100CS0J5-18RDN Overview

Cable Assembly, 30AWG,

177-740-5-100CS0J5-18RDN Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7005076781
Reach Compliance Codecompliant
Country Of OriginUSA
YTEOL8.23
Other featuresSTANDARD: MIL-DTL-83513
CertificationMIL
Conductor surface treatmentSILVER
conductor materialCOPPER
ConnectorSide1MICRO-D MALE
ConnectorSide2MICRO-D FEMALE
Connector bracket typeCABLE ASSEMBLY
structureSTRANDED
Cross-sectional area0.051 mm2
DIN complianceNO
IEC complianceNO
insulator materialCROSSLINKED ETHYLENE-TETRAFLUOROETHYLENE
length0.467 mm
MIL complianceYES
Number of conductors100
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
Rated current3 A
Rated voltage150 V
resistance0.385 Ω
shieldNO
stay7X38
Wire gauge30 AWG
Wire and Cable NamesFLEXIBLE CORD AND FIXTURE WIRE
B
SHIELDING EFFECTIVENESS (Db)
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
SHIELDING EFFECTIVENESS (Db)
Micro-D Harness
EMI Performance with Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
MWDM Micro-D
Shielded Cable Assembly
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly labor. 100%
tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair 177-740
cables are furnished with a full complement of white/blue twisted
pair wires.
Integral Shield Termination–The
connector shell has a platform
to accept Band-It shield termination bands. The cable shield braid is
attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding
with Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s
fully shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-
piece connector shell and secured with a stainless steel
Band-Master™ ATS
clamp. These pre-wired, 100% tested
assemblies meet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low
shell-to-shell resistance. Available with a variety of wire types and shields, Micro-D shielded assemblies can be
ordered in any length, either single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
A gold-plated stainless steel ground spring on the pin connector mating
face offers substantial improvement in EMI protection. The graphs
compare identical connectors tested with and without ground springs.
EMI Performance without Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
frequency (Hz)
frequency (Hz)
© 2013 Glenair, Inc.
High Performance Micro-D Connectors and Cables
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
B-14
E-Mail: sales@glenair.com
Switching Power Supply Theory and Design
This book introduces the theory and design methods of switching power supplies while taking into account both practicality and theory. It is a book specially written for researchers and engineers enga...
arui1999 Download Centre
Who is calling me home?
The village in my heartis in heaven. In my heart is avillage called Taoyuan. When the spring breezeblows, peach blossoms stagger up the hill. Flowersbloom and fall, and the river beside the village ha...
maker Talking
Choose the crystal oscillator clearly
Paul Rako, technical editor at EDN Silicon and MEMS oscillators are joining quartz crystals and ceramic resonators in the highly fragmented oscillator market. You don't need a crystal ball to choose t...
cscl Energy Infrastructure?
Share a few blog posts related to power supply
[url=http://www.deyisupport.com/blog/b/power_house/archive/2015/08/24/52046.aspx][size=3]Portable Speaker Power: Making the Bass Possible[/size][/url] [size=3][/size] [size=3][color=#000]Many manufact...
eric_wang TI Technology Forum
【Design Tools】 "CPLD, FPGA Advanced Application Development Guide"
Contents Chapter 1 Programmable Logic Devices and EDA Technology 1.1 Programmable Logic Devices and Their Characteristics 1.1.1 Simple PLD 1.1.2 CPLD 1.1.3 FPGA 1.1.4 Gate Array 1.1.5 Standard Cell Me...
GONGHCU FPGA/CPLD
lm393 problem
lm393 is connected to 5v power supply and ground, the positive input is 2.5v, and the negative input is left floating, what will happen to the output...
wd5039 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1201  107  816  1615  46  25  3  17  33  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号