DPM2000S

Description
lcd dpm 5V/200mv 3.5 dig S-rail
CategoryTopical application    Test and measurement   
File Size94KB,2 Pages
ManufacturerMartel
Websitehttp://www.martelelectronics.com
Download Datasheet Parametric Compare View All

DPM2000S Overview

lcd dpm 5V/200mv 3.5 dig S-rail

DPM2000S Parametric

Parameter NameAttribute value
Datasheets
DPM2000
Standard Package1
CategoryIndustrial Controls, Meters
FamilyPanel Meters
TypeVoltage (Voltmeter)
Measuring Range0 ~ 200mVDC
Display TypeLCD - Black Characters
Number Of Characters Per Row3.5
Display Characters - Heigh0.591" (15.00mm)
Output TypeReference
Voltage - Supply5VDC
Panel Cutout Dimensions-
Mounting TypePanel Mount - Bezel
Termination StylePC Pi
Ingress Protecti-
Features-
Operating Temperature0°C ~ 50°C
Weigh-
Other Names80074DPM2000S-NDQ2608468
DPM 2000
15mm (0.6“) Digit Height
Programmable Decimal Points
Auto-zero
Auto-polarity
200mV d.c. Full Scale Reading (F.S.R.)
Single Rail Version
3
½ Digit LCD Module
The DPM 2000 uses advanced components and construction techniques to provide an unrivalled combination of high performance,
elegant appearance and low cost. The module uses a bandgap reference for extra temperature stability. For single rail operation, the
DPM 2000S features a built-in negative rail generator, enabling the meter to measure a signal referenced to its own power supply 0V.
Two resistors Ra and Rb may be fitted in order to alter
the full scale reading (F.S.R) of the meter - see table.
The meter will need re-calibration.
Required F.S.R.
2V
20V
200V
2kV
200
µ
A
2mA
20mA
200mA
NOTE
Note
Note
Note
Note
910k
1M
1M
1M
link
link
link
link
SCALING
Standard Meter
Single Rail Version
Accuracy (overall error) *
Linearity
Sample rate
Operating temperature range
Temperature stability
Supply voltage
DPM 2000
(V+ to V-)
DPM 2000S
Supply current
DPM 2000
DPM 2000S
Input leakage current (Vin = 0V)
Stock Number
Min.
Typ.
0.05
3
30
9
5
150
500
1
DPM 2000
DPM 2000S
Ra
100k
10k
1k
100R
1k
100R
10R
1R
Rb
Specification
Max.
0.1
±1
50
14
6.5
10
0
7.5
3.5
% (±1 count)
count
samples/sec
°C
ppm/°C
V
µ
A
pA
Unit
Ensure that link 10 is open if fitting Ra.
* To ensure maximum accuracy, re-calibrate periodically.
SAFETY
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. If voltages to the measuring
inputs do exceed 60Vdc, then fit scaling resistors externally to the module. The user must ensure that the incorporation of the DPM into the user’s
equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for Measuring, Control and Laboratory Use).
DIMENSIONS
All dimensions in mm (inches)
72.0
(2.83)
a b
6
11 4 2 7
12
13
Display in TEST mode
67.5 (2.66)
60.0 (2.36)
Ø2.50
(0.10)
c d e
+
-
LMP
(1.42)
9
H5
8
ON BOARD
SOLDER LINKS
SCALING RESISTORS
36.0
14
1
Rb
Ra
5
10
3
f
g
m
M
K
DP1
DP2
DP3
~
:
-
pH
µ
%
V
g
°F
°C
A
a.
b.
c.
d.
e.
f.
g.
1.00
9.00
1.25
5.50
4.00
0.50
2.54
(0.04)
(0.35)
(0.05)
(0.22)
(0.16)
(0.02)
(0.10)
32.5 (1.28)
27.5 (1.08)
29.5 (1.16)
19.0 (0.75)
29.5 (1.16)
E3
BP
AB
POL
REF HI
REF LO
COM
I
L
XDP
-5V
CLK
XG3
V+
RBG
REF-
REF+
TEST
XB3
53.0 (2.09)
62.5 (2.46)
I
H
V-

DPM2000S Related Products

DPM2000S DPM2000
Description lcd dpm 5V/200mv 3.5 dig S-rail meter dpm lcd3.5digit 200mv IN

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 259  2828  1941  438  2484  6  57  40  9  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号