EEWORLDEEWORLDEEWORLD

Part Number

Search

3600-P10-SI-3A

Description
cir brkr thrmmag 3A 250vac 65vdc
CategoryCircuit protection   
File Size297KB,4 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet Parametric Compare View All

3600-P10-SI-3A Online Shopping

Suppliers Part Number Price MOQ In stock  
3600-P10-SI-3A - - View Buy Now

3600-P10-SI-3A Overview

cir brkr thrmmag 3A 250vac 65vdc

3600-P10-SI-3A Parametric

Parameter NameAttribute value
Datasheets
3600, 3900 Series
3600/3900-P10 Series
Standard Package10
CategoryCircuit Protecti
FamilyCircuit Breakers
Breaker TypeThermal Magnetic
Current Rating3A
Voltage Rating - AC250V
Voltage Rating - DC65V
Number of Poles1
Actuator TypePush to Rese
Illuminati-
Illumination Voltage (Nominal)-
Mounting TypePanel Mou
Other Names3600-P10-SI-3AMPQ1837149A
Thermal-Magnetic Circuit Breakers 3600/3900
Description
Single pole thermal-magnetic circuit breaker with tease-free, trip-free,
snap action mechanism and two button operation (M-type TM CBE
to EN 60934). Designed for plug-in mounting with E-T-A sockets
17-P10-Si, 23-P10-Si, 63-P10-Si; or panel mounting using E-T-A clips.
Featuring an unprotected shunt tap terminal and optional auxiliary
contacts. Type 3900 offers lower internal resistance values and is fitted
as standard with auxiliary contacts and an intermediate reset position
in which all contacts are isolated.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Process control systems, instrumentation, communications systems,
rail vehicles.
standard type
3600
3900
low-resistance type
Ordering information
Type No.
3600
standard version with shunt tap terminal -3
3900
low-resistance version
Terminal design
P10
blade terminals 6.3-0.8 (QC .250)
Auxiliary contacts (3900: intermediate position as standard)
Si
with blade terminals 6.3-08,one each NO/NC,
Current ratings
0.05...16 A
(type 3600)
0.05...10 A
(type 3900)
3600 - P10 - Si -
10 A
ordering example
Technical data
For further details please see chapter: Technical Information
Voltage rating
AC 240 V, 50/60 Hz; DC 65 V
(UL: AC 250 V; DC 65 V)
Current rating range
3600: 0.05...16 A
3900: 0.05...10 A
Auxiliary circuit
1 A, AC 240 V / DC 65 V
Typical life
5,000 operations at 1 x I
N
, inductive
5,000 operations at 2 x I
N
, resistive
Ambient temperature
-30...+60 °C (-22...+140 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664 A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area
AC 3,000 V
main/aux. circuit
AC 1,500 V
aux. circuit 4-5/6-7
AC 840 V
Insulation resistance
>100 MΩ (DC 500 V)
Interrupting capacity I
cn
3600
3900
0.05...0.8 A 0.05...0.2 A self-limiting
1...2 A
0.3...2 A
200 A
2.5...16 A
2.5...10 A
400 A
Interrupting capacity
I
N
U
N
(UL 1077)
0.05...16 A
AC 250 V
1,000 A
type 3600: 0.05...16 A
DC 80 V
1,000 A
Degree of protection
operating area IP40
(IEC 60529/DIN 40050)
terminal area IP00
Vibration
5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock
25 g (11 ms) to IEC 60068-2-27, test Ea
Corrosion
96 hours at 5 % salt mist
to IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass
approx. 45 g
3
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Preferred types
Preferred types
3600-P10-Si-
3900-P10-Si-
Standard current ratings (A)
0.5
x
x
1
x
x
2
x
x
4
x
x
8
x
10
x
16
x
Standard current ratings and typical internal resistance values
Current
ratings
(A)
Internal resistance
(Ω)
3600
3900
Current
ratings
(A)
Internal resistance
(Ω)
3600
3900
0.05
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.5
2
2.5
447
131
40
19.3
10.4
7.1
4.3
2.5
1.67
0.61
0.38
0.24
211
48
12.4
5.4
3.1
2.0
1.32
0.76
0.49
0.21
0.101
0.078
3
4
5
6
7
8
10
12
14
15
16
0.19
0.090
0.061
0.041
0.034
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
0.054
0.035
0.025
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
2015/16
www.e-t-a.de
3
- 51

3600-P10-SI-3A Related Products

3600-P10-SI-3A 3600-P10-SI-0.1A 3600-P10-SI-0.5A 3600-P10-SI-3.5A 3600-P10-SI-0.6A 3600-P10-SI-0.2A 3600-P10-SI-1.5A 3600-P10-SI-2.5A
Description cir brkr thrmmag 3A 250vac 65vdc cir brkr thrm .1A cir brkr 500ma 250vac 65vdc cir brkr 3.5A 250vac 65vdc cir brkr 600ma 250vac 65vdc cir brkr 200ma 250vac 65vdc cir brkr 1.5A 250vac 65vdc cir brkr 2.5A 250vac 65vdc
The video test program in wince6.0 has no response
I downloaded the wince6.0 driver provided by Microsoft from the Internet, compiled it, and transplanted it to the development board. When I insert the camera, the dialog box for selecting the driver i...
garfield_nuo Embedded System
PIC16F630-676 Data Sheet
This article is about the data sheet of a series of PIC...
rain Microchip MCU
Electromagnetic Controlled Motion Device (J)
Tasks and requirements Design and manufacture an electromagnetically controlled motion device, which consists of an electromagnetic control device, a pendulum rod and other parts. (1) Press the start ...
兰博 Electronics Design Contest
Switching power supply art appreciation-very beautiful power supply
Switching power supply art work...
okhxyyo Power technology
Some cases of DSP program crash (flying away) - hardware reasons
[p=30, null, left] DSP is different from FPGA. Programs running on DSP may crash, that is, run away. Checking crashes is basically what every DSP or embedded engineer will experience when debugging. D...
fish001 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1287  1569  734  702  1132  26  32  15  23  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号