Indication method
No
Temperature
mode ON/OFF indication
Controller
Proportional
Control
Input/ Thermo- K (CA)
stan- couple
Chromel
dard
vs. alumel
scale
(°C)
E5C2
Input
J (IC)
(P)
Relay
E5C2-R20K
E5C2-R20K
E5C2-R20K
E5C2-R20K
E5C2-R20K
E5C2-R40K
E5C2-R40K
E5C2-R40K
E5C2-R40K
E5C2-R40K
CSM_E5C2_DS_E_7A_1
Output
0 to 200
0 to 300
0 to 400
0 to 600
0 to 800
DIN-sized (48 x 48 mm)
E5C2-R20K ---
0 to 1,000
Temperature
Controller with Analog
E5C2-R20K ---
0 to 1,200
Setting
0 to 200
E5C2-R20J
---
• Compact, low-cost Temperature
E5C2-R20J
Controller.
---
Iron vs.
constantan 0 to 300
• Incorporates proportional control and reset adjustment function.
0 to 400
E5C2-R20J
---
• Consecutive mounting possible using mounting adapter.
• Incorporates a plug-in socket, thus allows to DIN-track and flush
mounting.
Refer to
Safety Precautions for All Temperature
Controllers.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Ordering Information
■
Temperature Controllers
Standard Models
Indication method
Control mode
Input
Output
0 to 200
0 to 300
0 to 400
K (CA) 0 to 600
Thermo-
couple
0 to 800
0 to 1000
0 to 1200
0 to 200
J (IC)
0 to 300
0 to 400
Control mode
Input
Output
0 to 200
E5C2-R40K
E5C2-R20K
E5C2-R20K
E5C2-R20K
E5C2-R20K
E5C2-R20K
E5C2-R20K
E5C2-R20K
E5C2-R20J
E5C2-R20J
E5C2-R20J
No indication
ON/OFF
Relay
E5C2-R20K-W
E5C2-R20K-W
--
--
E5C2-R20K-W
E5C2-R20K-W
E5C2-R20K-W
E5C2-R20K-W
E5C2-R20K-W
E5C2-R20K-W
Relay
E5C2-R40K-W
Ther- THE (re-
mistor placeable
element)
Input/
stan-
dard
scale
(°C)
Input
Resis-
tance
Ther-
mome-
ter
Indication method
Control mode
Output
Platinum
50
to 50
resistance
thermom-
20
to 80
eter Pt100 0 to 50
0 to 100
0 to 200
0 to 300
0 to 400
50
to 50
0 to 100
50 to 150
100 to 200
150 to 300
No indication
ON/OFF
Relay
E5C2-R20P-D
E5C2-R20P-D
E5C2-R20P-D
E5C2-R20P-D
E5C2-R20P-D
E5C2-R20P-D
E5C2-R20P-D
E5C2-R20G
E5C2-R20G
E5C2-R20G
E5C2-R20G
E5C2-R20G
Proportional
0 to 300
E5C2-R40K E5C2-R40K-W
■
Accessories (Order Separately)
0 to 400
E5C2-R40K
--
■
Accessories (Order Separately)
Protective Cover
Type
Hard Protective Cover
Model
Y92A-48B
Sockets
K (CA) 0 to 600
0 to 800
0 to 1000
0 to 1200
0 to 200
J (IC)
0 to 300
0 to 400
E5C2-R40K
E5C2-R40K
--
--
--
--
--
--
--
--
E5C2-R40K-W
E5C2-R40J-W
E5C2-R40J-W
E5C2-R40J-W
■
Thermo-
couple
Sockets
Note: 1.
No reset function is incorporated by any E5C2 model with
Name
Model
ON/OFF control.
Front Connecting
function is used to correct offset for proportional
P2CF-08
The reset
Socket
Back Connecting
there is an offset below the set value, turn the
P3G-08
control. If
Socket
reset adjustment clockwise.
Front Connecting Socket with Finger Protection
P2CF-08-E
2.
A
Cover
Watertight
protection)
Protective
special
(for finger
Cover is used to achieve this degree of
Y92A-48G
protection (IP66, NEMA4). Refer to
Y92A-
@@
N.
Model Number Structure
■
Model Number Legend
E5C2-
@ @ @
-
@
1 2
3
4
1. Control Outputs
R:
Relay
2. Control Method
cation
20: ON-OFF control
method
Control
40: Proportional control
mode
Input
Input/ Thermo- K (CA)
stan- couple
Chromel
dard
vs. alumel
scale
(°C)
E5C2
3. Input
K:
K-type thermocouple
J:
J-type thermocouple
No indication
P-D: Platinum resistance thermometer
ON/OFF
Proportional
(Pt100)
(P)
G:
Thermistor with replaceable ele-
Output
Relay
ment
0 to 200
E5C2-R20K
E5C2-R40K
4. Temperature Scale
0 to 300
0 to 400
0 to 600
0 to 800
E5C2-R20K
E5C2-R20K
E5C2-R20K
E5C2-R20K
Blank: Degrees C
W:
---
---
---
E5C2-R40K
E5C2-R40K
E5C2-R40K
Note:
A functional explanation is provided
here for illustration, but models are
not necessarily available for all
possible combinations. Refer to
Ordering Information
when ordering.
Examples
•
Relay control output, ON/OFF
control, type-K thermocouple input:
E5C2-R20K
•
Relay control output, proportional
control, thermocouple input: E5C2-
R40P-D
Both Degrees C and Degrees F
E5C2-R40K
Temperature Ranges
E5C2-R20K
Temperature Controllers
0 to 1,200
0 to 1,000
E5C2-R20K
E5C2-R20J
Input
E5C2-R20J
J (IC)
0 to 200
Iron vs.
constantan 0 to 300
0 to 400
Standard
scale
(°C)
Thermocouple
---
K (CA)
J (IC)
Iron vs. constantan
E5C2-R20J
Chromel vs. alumel
---
1,200
1,000
1,000
800
800
600
600
400
400
300
300
200
200
100
0
0
0
0
0
0
0
100
1,200
Resistance Thermometer
Platinum resistance
thermometer Pt100
Thermistor
Thermistor
(replaceable element)
Themistor nominal resistance
6 k 6 k 30 k 550
4 k
(0°C) (0°C) (0°C) (200°C)(200°C)
400
300
200
50
0
0
0
0
50 20
80
50
0
100
0
0
0
200
300
400
300
150
50
0
50
100
100
0
50
150
200
Setting
method
Indica-
tion
Control
method mode
Output
Minimum
scale division
(°C)
5
10 10 20 20 25 25
5
10
10
2
2
1
2
5
10 10
2
2
2
2
2
Analog No
ON/OFF
setting indi-
cation Propor-
tional
(P)
Relay
Relay
Model
Model
E5C2-R20K
E5C2-R40K
---
E5C2-R20J
---
E5C2-R20P-D
---
E5C2-R20G
---
N
Specifications
■
Ratings
Supply voltage
100 to 240 VAC 50/60 Hz
Operating voltage
90% to 110% of rated supply voltage
range
Power
consumption
Input
Approx. 3.6 VA
Thermocouple (with sensor burnout detection
circuit), platinum resistance thermometer, or
thermistor with replaceable element
ON/OFF or proportional control
Analog setting
No indication
Relay output: SPDT, 3 A at 250 VAC, resistive
load (switching capacity: 330 VA)
10C
to 55C (with no icing or condensation)
45% to 85%
Shock resistance
Life expectancy
Weight
■
Characteristics
Setting accuracy
Hysteresis
Proportional band
Control period
Reset range
Insulation
resistance
Dielectric strength
Vibration
resistance
2%
FS max.
Approx. 0.5% FS (fixed)
3% FS (fixed)
Approx. 20 s
5
1%
FS min. (See note 1.)
20 M min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between charged termi-
nals and uncharged metallic parts
Malfunction: 10 to 55 Hz, 0.15-mm single amplitude for
10 min each in X, Y, and Z directions
Destruction: 16.7 Hz, 2-mm double amplitude for 2 hrs
each in X, Y, and Z directions
Malfunction: 147 m/s
2
, 3 times each in 6 directions
Destruction: 294 m/s
2
, 3 times each in 6 directions
Electrical:
100,000 operations min. (3 A at 110 VAC,
resistive load)
Control method
Setting method
Indication
method
Control output
Ambient operat-
ing temperature
Ambient operat-
ing humidity
Approx. 100 g (with flush-mounting adapter)
Degree of protection
Front panel: IEC standard IP40 (See note 2.)
Terminals: IEC standard IP00
Applicable Socket
P2CF-08 (order separately),
P3G-08 (order separately)
Y92A-48B (order separately)
Note:
Do not use an inverter output as the power supply. (Refer to
Safety Precautions for All Temperature Controllers.)
Applicable Protec-
tive Cover
Note: 1.
No reset function is incorporated by any E5C2 model with
ON/OFF control.
The reset function is used to correct offset for proportional
control. If there is an offset below the set value, turn the
reset adjustment clockwise.
2.
A special Watertight Cover is used to achieve this degree of
protection (IP66, NEMA4). Refer to
Y92A-
@@
N.
2
E5C2
■
Connections
Connecting the Input
•
Connect a thermocouple, the E52-THE@ Thermistor (replaceable
element) or a platinum resistance thermometer to terminals 1
(positive) and 2 (negative) on the E5C2 as shown in the following
illustration.
Output
•
If the load circuit is a heating control system, be sure to connect the
load to terminals 4 and 5. If the load circuit is a cooling control
system, be sure to connect the load to terminals 4 and 6.
•
We recommend using an external relay to extend the electrical life
of internal relays when driving a large capacity load. This is
particularly important when the output relay is switched frequently
(e.g., with proportional control).
Platinum resistance
thermometer input
Thermocouple input
Power Supply
•
If a single power supply is used for the E5C2 and the load, the
supply voltage of the power supply may vary greatly when the load
is open or closed if the capacity of the power supply is not large
enough. Make sure that the capacity of the power supply is large
enough so that the supply voltage range will be always from 90% to
110% of the rated supply voltage.
•
The E5C2 operates at either 50 or 60 Hz.
Thermistor
with
replaceable element
Power supply
100/110/120
VAC
(same model) or
200/220/240
VAC
(same model)
50/60 Hz
•
On the E52-@@1D, the lead wires are thermocouple element wires,
making them difficult to solder because solder will not stick to them
easily. Remove the crimp terminal and polish the ends before
attempting to solder them.
Nomenclature
Temperature setting knob
Operation Indicator
Indicator
Operation indicator
Output
NO contacts (4 and 5) NC contacts (4 to 6)
ON
OFF
OFF
ON
Red
Lit
Not lit
RESET adjustment shaft
No
reset function is incorporated
by
any
E5C2 model
with
ON/OFF control.
3
E5C2
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
48 x 48
Terminal Arrangement
(Bottom View)
44.8 x 44.8
Dimensions with Flush-mounting Adapter (Accessory),
and Back Connecting Socket (Sold Separately)
Flush-mounting
adapter
Panel
Y92F-30 Flush-mounting adapter
P3G-08 Back
connecting socket
Tightening screw
(96)
Panel Cutout
Side-by-side Mounting
of N Controllers
Qty.
L
2
3
4
5
6
93
+1
141
+1
189
+1
237
+1
285
+1
0
0
0
0
0
60 min.
Note: 1.
Recommended panel thickness is 1 to 4 mm.
2.
Close side-by-side mounting is possible (in a single direction).
■
Accessories (Order Separately)
Connection Sockets
P2CF-08 Front Connecting Socket
Eight, M3.5 x 7.5 sems
Terminal Arrangement/
Internal Connections
(Top View)
Mounting Holes
Two, 4.5 dia. or two, M4
70 max.
Two,
4.5-dia.
holes
Note:
Can also be
mounted to a
DIN track.
20 max.
50 max.
Note:
A finger-protection model (P2CF-08-E) is also available.
P3G-08 Back Connecting Socket (for Flush Mounting)
27 dia.
Terminal Arrangement/
Internal Connections
(Bottom View)
Note:
A Protective Cover for finger protection (Y92A-48G) is also available.
4
E5C2
Hard Protective Cover
A Hard Protective Cover (Y92A-48B) is available. It can be used in
the following cases.
•
To protect the setting section, against dust and dirt
•
To prevent accidently changing settings by touching the front of the
Controller.
•
To protect the Controller from water drips
Appearance
Applicable Thermistor
Connect a Thermistor with a replaceable element (E52-THE5A, E52-
THE6D, or E52-THE6F) to the E5C2-R20G. Refer to
E52
for details.
Model
Y92A-48B
Safety Precautions
Refer to
Safety Precautions for All Temperature Controllers.
■
Correct Use
Mounting
Track Mounting (E5C2 with P2CF-08)
When mounting two or more E5C2 models with track-mounting
sockets, leave a space of approximately 20 mm on both sides of the
sockets where hooks are located.
The P3G-08 can be wired in the same way as the P2CF-08.
Hook
Duct
Dismounting
If flush mounted, loosen the screw of the adapter and disengage the
hooks for dismounting.
P2CF-08
Panel
20
Flush Mounting
Insert E5C2 into the square hole of the panel and insert an adapter
from the back so that there will be no space between E5C2 and the
panel. Then, secure the E5C2 with a screw.
Temperature Setting
Do not turn the temperature setting knob of the E5C2 with excessive
force, otherwise the stopper of the knob may break.
Others
Tightening screw
•
Do not remove the housing of the E5C2, otherwise the housing
may break.
•
To clean the surface of the E5C2, use a soft cloth wet with neutral
detergent or alcohol. Do not use any organic solvent, such as paint
thinner or benzine, strong acid or strong alkali to clean the surface
of the E5C2, otherwise the surface of the E5C2 will become
damaged.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.