PAF500F24-*
SPECIFICATIONS
C169-01-01A
MODEL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
ITEMS
Nominal Output Voltage
Maximum Output Current
Nominal Output Power
Efficiency (Typ.)
Input Voltage Range
Input Current (Typ.)
Output Voltage Accuracy
Output Voltage Range
Maximum Ripple & Noise
Maximum Line Regulation
Maximum Load Regulation
Over Current Protection
Over Voltage Protection
Remote Sensing
Remote ON/OFF Control
Parallel Operation
Series Operation
I.O.G. Signal
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Cooling
Temperature Coefficient
Withstand Voltage
V
A
W
(*1) %
-
(*2) A
(*2) %
(*10) -
(*10) mV
(*3) mV
(*4) mV
(*5)
-
(*6)
-
(*9)
-
(*9)
-
(*9)
-
(*9)
-
(*9)
-
(*7)
-
-
-
-
(*8)
-
-
-
-
-
-
-
-
g
mm
PAF500F24-12
12
42
504
89
19 - 36VDC
24.0
±1
-40%, +10%
200
24
24
DENSEI-LAMBDA
PAF500F24-28
28
18
504
90
18 - 36VDC
23.8
280
56
56
26 Isolation Resistance
27 Vibration
28 Shock
29 Weight (Typ.)
30 Size (W×H×D)
105% - 140%
115% - 135%
Possible
Possible (SHORT:ON OPEN:OFF)
Possible
Possible
Possible (Open Collector Output)
o
o
-40 C - +100 C(Baseplate) Ambient Temperature min=-40
o
C
20 - 95%RH (No Dewdrop)
-40
o
C - +100
o
C
10 - 95%RH (No Dewdrop)
Conduction Cooled
0.02%/
o
C
Input-Baseplate : 1.5kVDC, Input-Output : 1.5kVDC for 1min.
Output-Baseplate : 500VDC for 1min.
More than 100MΩ at 25
o
C and 70%RH Output-Baseplate...500VDC
At No Operating, 10-55Hz (Sweep for 1min.)
Amplitude 0.825mm Constant (Maximum 49.0m/s
2
) X,Y,Z 1 Hour each
196.1m/s
2
250
61×12.7×116.8 (Refer to Outline Drawing)
Derating Curve
100%
=NOTES=
*1. At 24VDC, 80% of Maximum Output Current and
Baseplate Temperature = +25
o
C
*2. At 24VDC and Maximum Output Current.
*3. 19 - 36VDC, Constant Load.(PAF500F24-12)
18 - 36VDC, Constant Load.(PAF500F24-28)
*4. No load - Full load, Constant input voltage.
*5. Constant current limiting with automatic recovery.
*6. Inverter shutdown method, Manual Reset.
*7. Ratings - Refer to Derating Curve on the Right.
- Load(%) is Percent of Maximum Output
Current.
*8. Heatsink has to be Chosen According to Instruction
Manual.
*9. Refer to Instruction Manual.
*10. External Components are Needed for Operation.
(Refer to Basic Connection and Instruction Manual)
80%
Load (%)
60%
40%
20%
0%
-40
-20
0
20
40
60
80
100
Baseplate Temperature (
o
C)