EEWORLDEEWORLDEEWORLD

Part Number

Search

RSP-320-7.5

Description
switching power supplies 300w 7.5V 40a power supply W/pfc
CategoryPower/power management    The power supply circuit   
File Size164KB,3 Pages
ManufacturerMEAN WELL
Websitehttp://www.meanwell.com
Download Datasheet Parametric Compare View All

RSP-320-7.5 Overview

switching power supplies 300w 7.5V 40a power supply W/pfc

RSP-320-7.5 Parametric

Parameter NameAttribute value
package instruction,
Reach Compliance Codecompliant
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Base Number Matches1
320W Single Output with PFC Function
RSP-320
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 90%
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC Fan with fan speed control function
1U low profile 30mm
Optional conformal coating models (RSP-320-
CC)
LED indicator for power on
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
RSP-320-2.5
2.5V
60A
0 ~ 60A
150W
2.35 ~ 2.85V
±0.5%
±1.5%
8ms at full load
RSP-320-3.3
3.3V
60A
0 ~ 60A
198W
100mVp-p
2.97 ~ 3.8V
±2.0%
±0.5%
±1.5%
230VAC /115VAC
124 ~ 370VDC
PF>0.98/115VAC at full load
79.5%
1.5 A/230VAC
40A/230VAC
81%
83%
4A/115VAC
88%
2A/230VAC
88%
RSP-320-4
4V
60A
0 ~ 60A
240W
100mVp-p
3.7 ~ 4.3V
±2.0%
±0.5%
±1.0%
RSP-320-5
5V
60A
0 ~ 60A
300W
150mVp-p
4.5 ~ 5.5V
±2.0%
±0.5%
±1.0%
RSP-320-7.5
7.5V
40A
0 ~ 40A
300W
150mVp-p
6 ~ 9V
±2.0%
±0.5%
±1.0%
RSP-320-12
12V
26.7A
0 ~ 26.7A
320.4W
150mVp-p
10 ~ 13.2V
±1.0%
±0.3%
±0.5%
RIPPLE & NOISE (max.)
Note.2
100mVp-p
VOLTAGE TOLERANCE
Note.3
±2.0%
1500ms, 50ms/230VAC
3000ms, 50ms/115VAC at full load
Note.4
88 ~ 264VAC
VOLTAGE RANGE
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
PF>0.95/230VAC
75.5%
2.7A/115VAC
20A/115VAC
<1mA / 240VAC
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
2.88 ~ 3.38V
3.8 ~ 4.5V
4.5 ~ 5.3V
5.75 ~ 6.75V
9.4 ~ 10.9V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
-30 ~ +70
(Refer to "Derating Curve")
13.8 ~ 16.2V
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
-40 ~ +85
, 10 ~ 95% RH
TEMP. COEFFICIENT
±
0.03%/
(0 ~ 50
)
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 5)
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
1.
2.
3.
4.
5.
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 , CCC GB4943 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3,GB9254 class B,GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
206.5K hrs min.
MIL-HDBK-217F (25
)
215*115*30mm (L*W*H)
0.9Kg; 15pcs/14.5Kg/0.78CUFT
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
Tolerance : includes set up tolerance, line regulation and load regulation.
Derating may be needed under low input voltages. Please check the derating curve for more details.
The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
6. For charging related applications, please consult Mean Well for details.
File Name:RSP-320-SPEC 2014-04-01

RSP-320-7.5 Related Products

RSP-320-7.5 RSP-320-3.3 RSP-320-4 RSP-320-12 RSP-320-5
Description switching power supplies 300w 7.5V 40a power supply W/pfc switching power supplies 198w 3.3V 60a power supply W/pfc switching power supplies 240w 4V 60a power supply W/pfc switching power supplies 320.4W 12v 26.7A power supply W/pfc switching power supplies 300w 5V 60a power supply W/pfc
Reach Compliance Code compliant compliant - compliant compliant
Analog Integrated Circuits - Other Types AC-DC POWER FACTOR CORRECTION MODULE AC-DC POWER FACTOR CORRECTION MODULE - AC-DC POWER FACTOR CORRECTION MODULE AC-DC POWER FACTOR CORRECTION MODULE
Base Number Matches 1 1 - 1 1
STM8AD port stupid problem
STM8 should have 7 AD ports in total, but why is PC4 marked as AIN2 and PD2 as AIN3 in the pin diagram? I used these two ports as AD ports when I designed it, and the PCB was also drawn wrong. Can any...
csfcsf stm32/stm8
Let's call together, the leader of portable oscilloscopes [EEWorld 15th Anniversary Tool DIY Event]
EEWorld 15th Anniversary Tool DIY Activity. Based on everyone’s suggestions and feasibility, we have initially discussed advancing the production of three tools (Click here to view the overall progres...
EEWORLD社区 Test/Measurement
Problems with measuring AC current
I would like to ask you, when measuring AC current 0 ~ 100 A, is it better to use an AC transformer or a resistor?...
绿茶 Test/Measurement
Op amp replacement
TI's op amp TLV272 is too expensive. I only use it for temporary debugging. What can I use as an alternative?...
xie675101459 Analog electronics
Help: How to write the initialization modules in the design of a compound frequency meter based on F2812?
I am a beginner of 2812 and want to make a compound digital frequency meter, but I don't know much about 2812. When initializing the module programming, I don't know how to initialize GPIO, and I don'...
emanon0001 Microcontroller MCU
Application of Vishay's new electronic components in industry and new energy (ZT)
Application of Vishay's new electronic components in industry and new energy (ZT) In photovoltaic inverters and wind power converters, Vishay DC-link film capacitors can be used as voltage stabilizati...
jameswangsynnex Energy Infrastructure?

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 606  1421  597  900  2893  13  29  19  59  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号