3.6KVWJON65

Description
Electric Fuse, 5A, 3600VAC, 3600VDC, 50000A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size56KB,1 Pages
ManufacturerEaton
Download Datasheet Parametric View All

3.6KVWJON65 Overview

Electric Fuse, 5A, 3600VAC, 3600VDC, 50000A (IR), Inline/holder,

3.6KVWJON65 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
body height35.6 mm
Body length or diameter192 mm
Circuit protection typeELECTRIC FUSE
Installation featuresINLINE/HOLDER
physical size192mm x 35.6mm
Rated breaking capacity50000 A
Rated current5 A
Rated voltage (AC)3600 V
Rated voltage (DC)3600 V
surface mountNO
Terminal shapeTAB/BLADE
Base Number Matches1
Medium Voltage Fuses
British Standard dimensioned IEC fuses for
motor circuit protection
The Cooper Bussmann® range of motor fuses are designed
to meet the specific requirements necessary for motor
protection. During the starting cycle of direct on-line motors,
the fuse elements will reach a considerably higher
temperature than during normal operation; (this is due to the
high amount of current the motor will draw as it starts,
typically, 6 times its normal load current value). This results
in expansion and contraction of the fuse elements and could
cause premature operation of the fuse.
Cooper Bussmann
®
motor fuses encompass an advanced
design to minimize this effect. This therefore, negates the
need to over specify the fuse rating due to high values of
motor starting current.
Cooper Bussmann
®
motor fuses operate extremely quickly
under heavy fault currents, resulting from the time / current
characteristic. Low power dissipation ensures low
temperature rise, important in multi-tier starters for example.
Switching (Arc), voltages are lower than permitted values,
therefore, 5.5kV fuses are also suitable for 4.8kV and
2.4kV circuits.
Table of Ratings
Basic Cat.
Number
WJON6
WDOH6
WFOH6
WDLSJ
WFLSJ
WDFHO
WFFHO
WKFHO
VFNHA
VKNHA
WFNHO
WKNHO
WFMSJ
WKMSJ
Volts
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
5.5kV
5.5kV
7.2kV
7.2kV
7.2kV
7.2kV
Breaking
Capacity
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
60kA
60kA
40kA
40kA
40kA
40kA
Dimensions - in (mm)
Amp Ratings
Length
Diameter
5, 6.3, 10, 16, 20, 25, 31.5, 40, 50
7.56 (192)
1.4 (35.6)
50, 63, 80, 100, 125
7.56 (192)
2 (50.8)
160, 200
11.5 (292.1)
3 (76.2)
50, 63, 80, 100, 125
11.5 (292.1)
2 (50.8)
160, 200
11.5 (292.1)
3 (76.2)
50, 63, 80, 100, 125
10 (254)
2 (51mm)
160, 200
10 (254)
3 (76.2)
250, 315, 355, 400
10 (254)
3 (76.2)
2R-6R
15.86 (402.8)
3 (76.2)
9R-24R
15.86 (402.8)
3 (76.2)
25, 31.5, 40, 50, 63, 80, 100, 125, 160 15.86 (402.8)
3 (76.2)
200, 224, 250, 315
15.86 (402.8)
3 (76.2)
25, 31.5, 40, 50, 63, 80, 125, 160
17.40 (442)
3 (76.2)
200, 224, 250, 315, 355
17.40 (442)
3 (76.2)
Dimensional Standard
BS 2692 (TA1) Interchangeable with GEC type K2 PA
BS 2692 (TA1) or DIN 43625
BS 2692 (TA1) or DIN 43625
DIN 43625
DIN 43625
BS 2692 (TA2)
BS 2692 (TA2)
BS 2692 (TA2)
N. American Practice
N. American Practice
BS 2692 (TA4)
BS 2692 (TA4)
DIN 43625
DIN 43625
Catalog Number Build-A-Code
kV
Basic Catalog Number
___
_____
Amps
___
80
For product Data Sheets, visit www.cooperbussmann.com/products/datasheet.asp
Ask a question about microcontroller selection
I want to develop a multi-physiological parameter monitoring instrument, such as measuring body temperature, pulse and blood oxygen content, and process and analyze these, realize storage, alarm displ...
千面魔军 Embedded System
Getting Started with FPGA_Testability Design for Hardware Circuit Design
Yesterday I read the FPGA debugging summary of EEWorld, which was well written, but he talked about it from the perspective of debugging. Today I will talk about some of my own experiences in how to d...
tx_xy FPGA/CPLD
Reduce network energy consumption using Power over Ethernet
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:54[/i] [p=22, null, left][color=rgb(51, 51, 51)][font=Arial, Helvetica, sans-serif, 宋体]PoE enables data and power to be transmitted ove...
wstt Mobile and portable
Wireless network card password cracking
Is there any better software or method to crack wireless network card password under WINDOWS?...
lysword Embedded System
AD9850 and AD9851 serial and parallel programs and wiring diagrams (adjusted)
[i=s]This post was last edited by paulhyde on 2014-9-15 02:53[/i] I hope it can be helpful to you...
guoguo8034 Electronics Design Contest
CCS5.2 cannot connect to XDS100V2
[align=left][color=#000]I would like to ask you, I use XDS100V2 to connect to CCS5.2, but now I can't connect to it, please help me analyze where the problem is. [/color][/align][align=left][color=#00...
sw0605 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2222  961  118  553  927  45  20  3  12  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号