D100ER
Series
Low Cost, 1W SIP
Tightly Regulated
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
•
1W Output Power
•
Tightly Regulated
•
Single & Dual Outputs
•
Miniature SIP Case
•
1,000 VDC Isolation
•
>3.5 MHour MTBF
•
24 Standard Models
•
Industry Standard Pin-Out
•
LOWEST COST!!
Parameter
Input Voltage Range
Input Filter
Reverse Polarity Input Current
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
Min.
4.75
11.4
22.8
Typ.
5.0
12.0
24.0
Max.
5.25
12.6
25.2
0.3
Units
VDC
Internal Capacitor
A
Units
%
%
%
%
mV P - P
%
±0.03
Momentary (1.0 Sec.)
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,000
1,000
60
100
Conditions
Ambient
Case
Min.
-40
-40
-55
Free Air Convection
RH, Non-condensing
95
%
Typ.
+25
Max.
+85
+90
+125
Typ.
Max.
Units
VDC
MΩ
pF
kHz
Units
ºC
ºC
ºC
%/ºC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation (Note 1)
Ripple & Noise (20 MHz) (Note 3)
Output Power Protection
Temperature Coefficient
Output Short Circuit
120
Dual Output , Balanced Loads
For Vin Min to Max
For Iout = 10% to 100%
10
±0.1
Conditions
Min.
Typ.
Max.
±3.0
±1.0
±0.25
±1.0
20
General
Parameter
Isolation Voltage
RoHS Compliant
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
MicroPower Direct
Physical
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Case Size (Single Output)
Case Size (Dual Output)
Case Material
Weight
0.77 x 0.24 x 0.40 Inches (19.6 x 6.0 x 10.2 mm)
1.08 x 0.37 x 0.47 Inches (27.5 x 9.5 x 12.0 mm)
Non-Conductive Black Plastic (UL94-V0)
0.07 Oz (2.1g)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Conditions
5 VDC Input
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
3.5
Min.
-0.7
-0.7
-0.7
Typ.
Max.
9.0
18.0
30.0
300
450
ºC
mW
VDC
Typ.
Max.
Units
MHours
Units
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
D101ER
D102ER
D103ER
D104ER
D105ER
D106ER
D107ER
D108ER
D111ER
D112ER
D113ER
D114ER
D115ER
D116ER
D117ER
D118ER
D121ER
D122ER
D123ER
D124ER
D125ER
D126ER
D127ER
D128ER
Input
Voltage (VDC)
Nominal
Range
5
4.75 - 5.25
5
4.75 - 5.25
5
4.75 - 5.25
5
4.75 - 5.25
5
4.75 - 5.25
5
4.75 - 5.25
5
4.75 - 5.25
5
4.75 - 5.25
12
11.4 - 12.6
12
11.4 - 12.6
12
11.4 - 12.6
12
11.4 - 12.6
12
11.4 - 12.6
12
11.4 - 12.6
12
11.4 - 12.6
12
11.4 - 12.6
24
22.8 - 25.2
24
22.8 - 25.2
24
22.8 - 25.2
24
22.8 - 25.2
24
22.8 - 25.2
24
22.8 - 25.2
24
22.8 - 25.2
24
22.8 - 25.2
Current (mA)
Full-Load No-Load
294
30
286
30
282
30
278
30
290
30
286
30
278
30
278
30
121
15
117
15
116
15
116
15
119
15
116
15
114
15
114
15
59
8
58
8
57
8
57
8
58
8
58
8
57
8
57
8
Output
Voltage Current
Current
(VDC) (mA, Max) (mA, Min)
5.0
200.0
20.0
9.0
111.0
12.0
12.0
83.0
9.0
15.0
67.0
7.0
±5.0
±100.0
±10.0
±9.0
±56.0
±6.0
±12.0
±42.0
±5.0
±15.0
±33.0
±4.0
5.0
150.0
15.0
9.0
111.0
12.0
12.0
83.0
9.0
15.0
67.0
7.0
±5.0
±100.0
±10.0
±9.0
±56.0
±6.0
±12.0
±42.0
±5.0
±15.0
±33.0
±4.0
5.0
150.0
15.0
9.0
111.0
12.0
12.0
83.0
9.0
15.0
67.0
7.0
±5.0
±100.0
±10.0
±9.0
±56.0
±6.0
±12.0
±42.0
±5.0
±15.0
±33.0
±4.0
Efficiency
(%, Typ)
68
70
71
72
69
70
72
72
69
71
72
72
70
72
73
73
70
72
73
73
72
72
73
73
Fuse Rating
Slow-Blow
(mA)
500
500
500
500
500
500
500
500
200
200
200
200
200
200
200
200
100
100
100
100
100
100
100
100
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. These units should not be operated with a load under 10% of full load.
Operation at no-load may cause damage to the unit.
3. These converters will operate without external components. However, when
measuring output ripple, it is recommended that an external ceramic capaci-
tor be placed from the +Vout pin to the -Vout pin for single output units
and from each output to common for dual output units. An input capacitor
will enhace stability
Output Capacitor
over temperature and
Input
Vin
Vout
input line variations.
Capacitor
Single
Dual
Recommended capaci-
5 VDC
4.7 μF
5 VDC 10.0 μF 4.7 μF
tor values are given in
2.2 μF
9 VDC
4.7 μF
2.2 μF
the table at right. For 12 VDC
applications requir- 24 VDC
1.0 μF
12 VDC 2.2 μF
1.0 μF
ing very low output
15 VDC 1.0 μF 0.47 μF
noise levels, a simple
LC filter should be effective.
4. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Derating Curve
Mechanical Dimensions
(Single Output)
Mechanical Dimensions
(Dual Output)
Pin
Connections
Pin
1
2
4
6
7
9
10
Single
Dual
+Vin
+Vin
-Vin
-Vin
-Vout No Pin
+Vout No Pin
No Pin +Vout
No Pin -Vout
No Pin Common
MicroPower Direct
www.micropowerdirect.com
292 Page Street, STE D, Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Notes:
•
All dimen
dimensions are typical in inches (mm)
•
Tolerance x.xx =
±
0.01 (
±
0.25)
•
Pin 1 is ma
marked by a “dot” or indentation
sid
on the side of the unit
•
FAX: (781) 344-8481
E-Mail: sales@micropowerdirect.com