Miniature Switches Series 83 161 DIN 41635 A
General specifications
Layout
Types
Part numbers for standard products with
connections of type
Components
Material
- Case : glass-filled polyamide (self-extinguishing version to UL 94 VO
and IEC 695-2-1 850° C - available on request)
- Button : polyamide
- Contacts : nickel silver or gold alloy (dual-current)
Actuators
- flat : stainless steel
- roller : stainless steel, glass-filled polyamide roller
- other types of polyamide
Approvals:
NF - UL/cUL
Operating curve
For type 83 161 5 - 5 SP 4136
For type 83 161 1 3
Number of
operations
Resistive circuit:
Inductive circuit
Number of
operations
c
L = 5 ms
R
a
cos
ϕ
= 0.8
831613 Mechanical
831611 durability
Resistive circuit:
inductive circuit
c
L = 5 ms
R
a
cos
ϕ
= 0.8
2
3
6
Features
Electrical characteristics
Current rating at 125/250 V
Current
Horsepower
A
HP
N (oz.)
N (oz.)
N (oz.)
N (oz.)
mm (in.)
mm (in.)
mm (in.)
mm (in.)
°C (°F)
Operations
mm (in.)
g (oz.)
Mechanical characteristics
Operating force - max.
Release force - min.
Total travel force - max.
Permitted overtravel force - max.
Rest position - max.
Tripping point
Differential travel
Overtravel - min. (OT)
Ambient operating temperature
Mechanical durability (for 2/3 OT)
Contact gap
Weight
{
{
Mechanical
durability
Contact type
C
(Form C) SPDT
B
(Form B) SPNC
A
(Form A) SPNO
Mechanical durability
Connections
Rating in
Amps
Rating in
Amps
For type 83 161 8
Number of
operations
Resistive circuit:
For type 83 161 9 SP 4136
Number of
operations
Resistive circuit:
2
solder
3
for 1/4˝ Quick Connects
A
79 215 740
Flat
161A
R14.2 (.56)
Actuators and mounting positions
Part numbers for standard actuators
Actuators-Length
Mechanical
durability
mm (in.)
Mechanical
durability
Mounting positions
Coefficient
Tripping point (except 83 161 6)
Tripping point 83 161 6
Rating in
Amps
Rating in
Amps
A
2
15.2
±1
(.6
±.004
)
14.8
±1
(.59
±.004
)
B
1
15.2
±0.45
(.6
±.018
)
15
± 0.45
(.59
±.018
)
Part numbers for standard actuators
Actuators-Length
mm (in.)
H
79 218 651
Dummy roller
161G
R21.8 (.86)
For types 83 161 8 - 9 SP 4136 dual-current
Models 83 161 8 and 83 161 9 SP 4136 are designed to operate equally
well on dual-current (1 mA 4 V minimum) or medium-current
(5 A maximum) circuits.
However, a given product should only be used to switch one type of
circuit during its working life.
Mounting positions
A
B
Coefficient
3
1.8
Tripping point (except 83 161 6)
21.7
±2
(.85
±.08
) 21.7
±0.7
(.85
±.03
)
Tripping point 83 161 6
21.5
±2
(.85
±.08
) 21.5
±07
(.85
±.03
)
Except where otherwise indicated, flat and roller actuators are supplied unmounted.
Other information
For other forces, actuators, connections and temperatures,
please consult us.
Normally stocked items
Catalog products produced
to order
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
3/14
1
83161.1(10.1A)
831611C2.0
831611C3.0
831611C6.0
High Force
10.1
1/2
3 (10.5)
1 (3.5)
4.5 (15.8)
20 (70.5)
16.1 (0.63)
14.7
±0.4
(.58
±0.16
)
0.35 (0.014)
1.1 (0.05)
-20 +125 (-4 +257)
10
7
0.4 (0.016)
5.6 (.2)
C
B
A
83161.2(15.1A)
831612C2.0
831612C3.0
831612C6.0
High Current
15.1
1/2
0.8 (2.8)
0.2 (0.7)
2 (7.0)
20 (70.5)
16.2 (0.64)
14.7
±0.3
(.58
±0.16
)
0.35 (0.014)
1.2 (0.05)
-20 +125 (-4 +257)
2 x 10
7
0.4 (0.016)
5.6 (.2)
C
B
A
83161.3(10.1A)
831613C2.0
831613C3.0
831613C6.0
Standard
10.1
1/2
0.8 (2.8)
0.2 (0.7)
2 (7.0)
20 (70.5)
16.2 (0.64)
14.7
±0.3
(.58
±0.16
)
0.35 (0.014)
1.2 (0.05)
-20 +125 (-4 +257)
2 x 10
7
0.4 (0.016)
5.6 (.2)
C
B
A
83161.5(4A)
83161.9(0.1A)
831615C2.0
831615C3.0
831615C6.0
Low Force
4
1/10
0.25 (0.9)
0.05 (0.18)
0.35 (1.2)
20 (70.5)
16.3 (0.64)
14.7
±0.4
(.58
±0.16
)
0.35 (0.014)
1.1 (0.05)
-20 +125 (-4 +257)
5 x 10
7
0.4 (0.016)
5.6 (.2)
C
B
A
83161.5SP4136
83161.9SP4136
●
●
●
83161.6
831616C2.0
831616C3.0
831616C6.0
Wide Gap
6.1
1/3
5 (18)
0.5 (1.8)
6 (21.6)
20 (70.5)
16.1 (0.63)
14.5
±0.4
(.58
±0.16
)
0.8 (0.03)
0.9 (0.035)
-20 +125 (-4 +257)
5 x 10
4
3.2 (0.126)
5.6 (.2)
C
B
A
83161.8(0.1A)
831618C2.0
831618C3.0
831618C6.0
Dual Current
0.1
N/A
0.8 (2.8)
0.2 (0.7)
0.2 (.07)
20 (70.5)
16.2 (0.64)
14.7
±0.4
(.58
±0.16
)
0.35 (0.014)
1.2 (0.05)
-20 +125 (-4 +257)
2 x 10
7
0.4 (0.016)
5.6 (.2)
Ultra Light Force
4
1/10
0.15 (0.54)
0.04 (0.14)
0.2 (0.72)
20 (70.5)
16.3 (0.64)
14.7
±0.3
(.58
±0.16
)
0.35 (0.014)
1.2 (0.05)
-20 +125 (-4 +257)
5 x 10
7
0.4 (0.016)
5.6 (.2)
C
B
A
2
C
B
A
3
3
5
screw
6
for 3/16˝ Quick Connects
7
for .11 Quick Connects
4
B
70 507 524
Flat
161A
R25.4 (1)
E
79 215 742
Roller
161E
R13.6 (.54)
G
70 507 529
Roller
161E
R24.1 (.95)
F
70 507 528
Dummy
161F
roller R22.2 (.84)
A
4
15.2
±2.5
(.6
±.1
)
14.4
±2.5
(.56
±.1
)
B
2
15.2
±1
(.6
±.04
)
14.8
±1
(.58
±.04
)
C
1.5
15.2
±0.8
(.6
±.03
)
14.9
±0.8
(.59
±.03
)
A
2
20.5
±1.5
(.81
±.06
)
20.1
±1.5
(.79
±.06
)
B
1
20.5
±0.8
(.81
±.03
)
20.3
±0.8
(.80
±.03
)
A
4
20.5
±2.9
(.81
±.11
)
19.7
±2.9
(.76
±.11
)
B
2
20.5
±1.5
(.81
±.06
)
20.1
±1.5
(.79
±.06
)
C
1.5
20.5
±1.2
(.81
±.05
)
20.2
±1.2
(.79
±.05
)
A
3
20.4
±2
(.8
±.08
)
20.2
±2
(.79
±.08
)
B
C
1.8
1.5
20.5
±0.7
(.81
±.03
) 20.5
±0.9
(.81
±.035
)
20.2
±2
(.79
±.08
)
L
V
C
70 507 526
D
79 215 835
4
Flat
161A
R50 (1.9)
Flat
161A
R60 (2.39)
161V
** Telescopic
plunger
Manual action
161L
D Factory Mount only
D Factory Mount only
B
C
B
C
A
A
1
6
3
2
7
3.5
2.2
1
21.5
±1
(.85
±.04
)
15.2
±6.3
15.2
±2
15.2
±1.6
15.2
±6.9
15.2
±2.5
15.2
±2.3
18.35
±0.45
21.5
±1
(.85
±.04
)
For factory mounting, specify fixing position A, B or C
** For 83 161 1, 83 161 3, 83 161,6, 83 161 8, mounted in factory (supplied without nut)
To order, please specify :
5
1
Switch Type
831612 831619
831613 831616
831615 831611
831618
2
Contact Type
A
B
C
3
Connection
2
3
5
6
7
Example : 831612 C 3 • C A
4
Actuators
Ø
A
B
C
D
E
F
G
H
L
V
5
Actuator Position
A
C
B (std) D
A
B C
D
To order actuators seperately, use the 8 digit P/N
Example switch is 831612, SPDT, 1/4” Q.C., C actuator mounted in A position
Ø = No actuator